388 related articles for article (PubMed ID: 24548576)
1. Measurement of body composition changes during weight loss in obese men using multi-frequency bioelectrical impedance analysis and multi-compartment models.
Johnstone AM; Faber P; Gibney ER; Lobley GE; Stubbs RJ; Siervo M
Obes Res Clin Pract; 2014; 8(1):e46-54. PubMed ID: 24548576
[TBL] [Abstract][Full Text] [Related]
2. Use of the cellular model of body composition to describe changes in body water compartments after total fasting, very low calorie diet and low calorie diet in obese men.
Siervo M; Faber P; Gibney ER; Lobley GE; Elia M; Stubbs RJ; Johnstone AM
Int J Obes (Lond); 2010 May; 34(5):908-18. PubMed ID: 20142822
[TBL] [Abstract][Full Text] [Related]
3. Body water distribution in severe obesity and its assessment from eight-polar bioelectrical impedance analysis.
Sartorio A; Malavolti M; Agosti F; Marinone PG; Caiti O; Battistini N; Bedogni G
Eur J Clin Nutr; 2005 Feb; 59(2):155-60. PubMed ID: 15340370
[TBL] [Abstract][Full Text] [Related]
4. Using dilution techniques and multifrequency bioelectrical impedance to assess both total body water and extracellular water at baseline and during recombinant human growth hormone (GH) treatment in GH-deficient adults.
Janssen YJ; Deurenberg P; Roelfsema F
J Clin Endocrinol Metab; 1997 Oct; 82(10):3349-55. PubMed ID: 9329367
[TBL] [Abstract][Full Text] [Related]
5. Laparoscopic gastric banding and body composition in morbid obesity.
Guida B; Belfiore A; Angrisani L; Micanti F; Mauriello C; Trio R; Pecoraro P; Falconi C
Nutr Metab Cardiovasc Dis; 2005 Jun; 15(3):198-203. PubMed ID: 15955468
[TBL] [Abstract][Full Text] [Related]
6. Assessment of total body water and its compartments in elite judo athletes: comparison of bioelectrical impedance spectroscopy with dilution techniques.
Gonçalves EM; Matias CN; Santos DA; Sardinha LB; Silva AM
J Sports Sci; 2015; 33(6):634-40. PubMed ID: 25278240
[TBL] [Abstract][Full Text] [Related]
7. Accuracy of bioelectrical impedance spectroscopy in measuring changes in body composition during severe weight loss.
Cox-Reijven PL; van Kreel B; Soeters PB
JPEN J Parenter Enteral Nutr; 2002; 26(2):120-7. PubMed ID: 11873761
[TBL] [Abstract][Full Text] [Related]
8. Prediction of body water compartments in preterm infants by bioelectrical impedance spectroscopy.
Collins CT; Reid J; Makrides M; Lingwood BE; McPhee AJ; Morris SA; Gibson RA; Ward LC
Eur J Clin Nutr; 2013 Jan; 67 Suppl 1():S47-53. PubMed ID: 23299871
[TBL] [Abstract][Full Text] [Related]
9. Body water compartment measurements: a comparison of bioelectrical impedance analysis with tritium and sodium bromide dilution techniques.
Simpson JA; Lobo DN; Anderson JA; Macdonald IA; Perkins AC; Neal KR; Allison SP; Rowlands BJ
Clin Nutr; 2001 Aug; 20(4):339-43. PubMed ID: 11478832
[TBL] [Abstract][Full Text] [Related]
10. The use of multi-frequency impedance to determine total body water and extracellular water in obese and lean female individuals.
Steijaert M; Deurenberg P; Van Gaal L; De Leeuw I
Int J Obes Relat Metab Disord; 1997 Oct; 21(10):930-4. PubMed ID: 9347412
[TBL] [Abstract][Full Text] [Related]
11. Impact of food and fluid intake on technical and biological measurement error in body composition assessment methods in athletes.
Kerr A; Slater GJ; Byrne N
Br J Nutr; 2017 Feb; 117(4):591-601. PubMed ID: 28382898
[TBL] [Abstract][Full Text] [Related]
12. Body composition in patients with an ileostomy and inflammatory bowel disease: validation of bio-electric impedance spectroscopy (BIS).
Carlsson E; Bosaeus I; Nordgren S
Eur J Clin Nutr; 2002 Jul; 56(7):680-6. PubMed ID: 12080410
[TBL] [Abstract][Full Text] [Related]
13. Body fluid volumes measurements by impedance: A review of bioimpedance spectroscopy (BIS) and bioimpedance analysis (BIA) methods.
Jaffrin MY; Morel H
Med Eng Phys; 2008 Dec; 30(10):1257-69. PubMed ID: 18676172
[TBL] [Abstract][Full Text] [Related]
14. Role of bioimpedance spectroscopy in assessment of body water compartments in hemodialysis patients.
Cox-Reijven PL; Kooman JP; Soeters PB; van der Sande FM; Leunissen KM
Am J Kidney Dis; 2001 Oct; 38(4):832-8. PubMed ID: 11576887
[TBL] [Abstract][Full Text] [Related]
15. Total body water changes after an exercise intervention tracked using bioimpedance spectroscopy: a deuterium oxide comparison.
Moon JR; Smith AE; Tobkin SE; Lockwood CM; Kendall KL; Graef JL; Roberts MD; Dalbo VJ; Kerksick CM; Cramer JT; Beck TW; Stout JR
Clin Nutr; 2009 Oct; 28(5):516-25. PubMed ID: 19500888
[TBL] [Abstract][Full Text] [Related]
16. Loss of total body water and extracellular water assessed by multifrequency impedance.
Deurenberg P; Schouten FJ
Eur J Clin Nutr; 1992 Apr; 46(4):247-55. PubMed ID: 1600921
[TBL] [Abstract][Full Text] [Related]
17. Multi-frequency bioelectrical impedance for assessing total body water and extracellular water in elderly subjects.
Visser M; Deurenberg P; van Staveren WA
Eur J Clin Nutr; 1995 Apr; 49(4):256-66. PubMed ID: 7796783
[TBL] [Abstract][Full Text] [Related]
18. Changes in body composition during weight loss in obese subjects in the NUGENOB study: comparison of bioelectrical impedance vs. dual-energy X-ray absorptiometry.
Verdich C; Barbe P; Petersen M; Grau K; Ward L; Macdonald I; Sørensen TI; Oppert JM
Diabetes Metab; 2011 Jun; 37(3):222-9. PubMed ID: 21236715
[TBL] [Abstract][Full Text] [Related]
19. Influence of gender and body composition on hydration and body water spaces.
Ritz P; Vol S; Berrut G; Tack I; Arnaud MJ; Tichet J
Clin Nutr; 2008 Oct; 27(5):740-6. PubMed ID: 18774628
[TBL] [Abstract][Full Text] [Related]
20. Is bioelectrical impedance spectroscopy accurate in estimating total body water and its compartments in elite athletes?
Matias CN; Santos DA; Gonçalves EM; Fields DA; Sardinha LB; Silva AM
Ann Hum Biol; 2013 Mar; 40(2):152-6. PubMed ID: 23249164
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]