These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
84 related articles for article (PubMed ID: 24554072)
1. A detached pedestal during cardiac assist with Jarvik 2000. Vanhuyse F; Bertram M; Folliguet T; Villemot JP Eur J Cardiothorac Surg; 2014 Oct; 46(4):751. PubMed ID: 24554072 [No Abstract] [Full Text] [Related]
2. Successful replacement of a detached pedestal during support with Jarvik 2000. Centofanti P; Attisani M; Bosco GF; Khayat A; La Torre M; Baronetto A; Boffini M; Rinaldi M Int J Artif Organs; 2012 Feb; 35(2):152-5. PubMed ID: 22395918 [TBL] [Abstract][Full Text] [Related]
3. Use of Jarvik 2000 left ventricular assist device for treating acutely decompensated heart failure. Anastasiadis K; Antonitsis P; Papakonstantinou C; Westaby S Eur J Cardiothorac Surg; 2009 Jan; 35(1):172. PubMed ID: 19027317 [No Abstract] [Full Text] [Related]
4. Rapid pacing for the off-pump insertion of the Jarvik left ventricular assist device. Centofanti P; La Torre M; Attisani M; Sansone F; Rinaldi M Ann Thorac Surg; 2011 Oct; 92(4):1536-8. PubMed ID: 21958820 [TBL] [Abstract][Full Text] [Related]
6. From bench to bedside: Can the improvements in left ventricular assist device design mitigate adverse events and increase survival? Tarzia V; Di Giammarco G; Di Mauro M; Bortolussi G; Maccherini M; Tursi V; Maiani M; Bernazzali S; Marinelli D; Foschi M; Buratto E; Bejko J; Gregori D; Scuri S; Livi U; Sani G; Bottio T; Gerosa G J Thorac Cardiovasc Surg; 2016 Jan; 151(1):213-7. PubMed ID: 26548997 [TBL] [Abstract][Full Text] [Related]
7. Continuous-flow left ventricular assist device. Landzaat LH; Sinclair CT; Rosielle DA N Engl J Med; 2010 Mar; 362(12):1149; author reply 1149. PubMed ID: 20335596 [No Abstract] [Full Text] [Related]
8. Microaxial Flow Left Ventricular Assist Device as a Bridge to Transplantation after LVAD Malfunction. Reich HJ; Shah A; Azarbal B; Kobashigawa J; Moriguchi J; Czer L; Esmailian F Tex Heart Inst J; 2015 Dec; 42(6):572-4. PubMed ID: 26664315 [TBL] [Abstract][Full Text] [Related]
9. Driveline insulation as a conduit for left ventricular assist device pocket infection. Pinninti M; Thohan V; Sulemanjee NZ J Thorac Cardiovasc Surg; 2014 Jul; 148(1):e135-6. PubMed ID: 24755334 [No Abstract] [Full Text] [Related]
10. Interventional Occlusion of Left Ventricular Assist Device Outflow Graft After Pump Thrombosis and Partial Myocardial Recovery. Erkilet G; Westenfeld R; Saeed D Artif Organs; 2015 Aug; 39(8):729-30. PubMed ID: 26234453 [No Abstract] [Full Text] [Related]
11. Assist device malfunction due to kinking of cannula between heart and chest wall. Kato TS; Oda N; Hashimoto S; Ikeda Y; Ishibashi-Ueda H; Komamura K Asian Cardiovasc Thorac Ann; 2010 Dec; 18(6):598. PubMed ID: 21149415 [No Abstract] [Full Text] [Related]
12. Ventricular square-wave response: case illustrating the role of invasive hemodynamics in the management of continuous-flow left ventricular assist device dysfunction. Kapur NK; Jumean M; Halin N; Kiernan MS; DeNofrio D; Pham DT Circ Heart Fail; 2015 May; 8(3):652-4. PubMed ID: 25991809 [No Abstract] [Full Text] [Related]
13. Less invasive surgical and perfusion technique for implantation of the Jarvik 2000 left ventricular assist device. Gerosa G; Gallo M; Tarzia V; Di Gregorio G; Zanella F; Bottio T Ann Thorac Surg; 2013 Aug; 96(2):712-4. PubMed ID: 23910126 [TBL] [Abstract][Full Text] [Related]
14. Use of an automatic internal defibrillator to induce and maintain ventricular fibrillation during left ventricular assist device pump exchange. Levin MA; Anyanwu AC; Eggert CA; Mittnacht AJ J Thorac Cardiovasc Surg; 2014 Mar; 147(3):e17-8. PubMed ID: 24290714 [No Abstract] [Full Text] [Related]
15. Anterior approach to implant the Jarvik 2000 with retroauricular power supply. Siegenthaler MP; Martin J; Gutwald R; Bahr R; Westaby S; Schmelzeisen R; Beyersdorf F Ann Thorac Surg; 2005 Aug; 80(2):745-7. PubMed ID: 16039255 [TBL] [Abstract][Full Text] [Related]
16. Current technology: devices available for destination therapy. Takayama H; Yang JA; Naka Y Cardiol Clin; 2011 Nov; 29(4):499-504. PubMed ID: 22062197 [TBL] [Abstract][Full Text] [Related]
17. Images in cardio-thoracic surgery: Novacor left ventricular assist device inflow valve endocarditis. Gazzoli F; Grande AM; Pagani F; ViganĂ² M Eur J Cardiothorac Surg; 2009 May; 35(5):910. PubMed ID: 19269841 [No Abstract] [Full Text] [Related]
18. Pump outflow graft puncture in a patient with a HeartMate II ventricular assist device. Sareyyupoglu B; Lammert P; Gongora E; Zubieta JC; Zehr KJ Ann Thorac Surg; 2013 Apr; 95(4):e97-8. PubMed ID: 23522242 [TBL] [Abstract][Full Text] [Related]
19. Computed tomography correlates of inflow cannula malposition in a continuous-flow ventricular-assist device. Sorensen EN; Hiivala NJ; Jeudy J; Rajagopal K; Griffith BP J Heart Lung Transplant; 2013 Jun; 32(6):654-7. PubMed ID: 23582475 [No Abstract] [Full Text] [Related]
20. Evaluation of bend relief disconnection in patients supported by a HeartMate II left ventricular assist device. Waller AH; Dunne R; Stewart GC; Ghosh N; Gosev I; Rybicki FJ; Blankstein R; Couper GS; Steigner M Circ Cardiovasc Imaging; 2014 Sep; 7(5):844-8. PubMed ID: 25227237 [No Abstract] [Full Text] [Related] [Next] [New Search]