BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

221 related articles for article (PubMed ID: 24556160)

  • 1. Bi-pseudoenzyme synergetic catalysis to generate a coreactant of peroxydisulfate for an ultrasensitive electrochemiluminescence-based cholesterol biosensor.
    Zhang J; Wang W; Chen S; Ruo Y; Zhong X; Wu X
    Biosens Bioelectron; 2014 Jul; 57():71-6. PubMed ID: 24556160
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Bi-enzyme synergetic catalysis to in situ generate coreactant of peroxydisulfate solution for ultrasensitive electrochemiluminescence immunoassay.
    Wang H; Yuan R; Chai Y; Niu H; Cao Y; Liu H
    Biosens Bioelectron; 2012; 37(1):6-10. PubMed ID: 22621981
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Electrochemiluminescence of luminol enhanced by the synergetic catalysis of hemin and silver nanoparticles for sensitive protein detection.
    Jiang X; Chai Y; Wang H; Yuan R
    Biosens Bioelectron; 2014 Apr; 54():20-6. PubMed ID: 24240164
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An ultrasensitive peroxydisulfate electrochemiluminescence immunosensor for Streptococcus suis serotype 2 based on L-cysteine combined with mimicking bi-enzyme synergetic catalysis to in situ generate coreactant.
    Wang H; Yuan R; Chai Y; Cao Y; Gan X; Chen Y; Wang Y
    Biosens Bioelectron; 2013 May; 43():63-8. PubMed ID: 23277341
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An ultrasensitive electrochemiluminescent biosensor for the detection of concanavalin A based on poly(ethylenimine) reduced graphene oxide and hollow gold nanoparticles.
    Zhang J; Chen S; Ruo Y; Zhong X; Wu X
    Anal Bioanal Chem; 2015 Jan; 407(2):447-53. PubMed ID: 25433682
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Highly amplified electrochemiluminescence of peroxydisulfate using bienzyme functionalized palladium nanoparticles as labels for ultrasensitive immunoassay.
    Niu H; Yuan R; Chai Y; Mao L; Liu H; Cao Y
    Biosens Bioelectron; 2013 Jan; 39(1):296-9. PubMed ID: 22857905
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Electrochemiluminescent quenching of quantum dots for ultrasensitive immunoassay through oxygen reduction catalyzed by nitrogen-doped graphene-supported hemin.
    Deng S; Lei J; Huang Y; Cheng Y; Ju H
    Anal Chem; 2013 Jun; 85(11):5390-6. PubMed ID: 23659573
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Highly enhanced electrochemiluminescence based on pseudo triple-enzyme cascade catalysis and in situ generation of co-reactant for thrombin detection.
    Xiao L; Chai Y; Yuan R; Wang H; Bai L
    Analyst; 2014 Mar; 139(5):1030-6. PubMed ID: 24443720
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Amplified electrochemiluminescent aptasensor using mimicking bi-enzyme nanocomplexes as signal enhancement.
    Zhuo Y; Ma MN; Chai YQ; Zhao M; Yuan R
    Anal Chim Acta; 2014 Jan; 809():47-53. PubMed ID: 24418132
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cerium oxide-graphene as the matrix for cholesterol sensor.
    Zhang M; Yuan R; Chai Y; Wang C; Wu X
    Anal Biochem; 2013 May; 436(2):69-74. PubMed ID: 23380308
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A general strategy to prepare homogeneous and reagentless GO/lucigenin&enzyme biosensors for detection of small biomolecules.
    Gao L; Zhang H; Cui H
    Biosens Bioelectron; 2014 Jul; 57():65-70. PubMed ID: 24549137
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ultrasensitive luminol electrochemiluminescence for protein detection based on in situ generated hydrogen peroxide as coreactant with glucose oxidase anchored AuNPs@MWCNTs labeling.
    Cao Y; Yuan R; Chai Y; Mao L; Niu H; Liu H; Zhuo Y
    Biosens Bioelectron; 2012 Jan; 31(1):305-9. PubMed ID: 22088259
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Highly sensitive luminol electrochemiluminescence immunosensor based on ZnO nanoparticles and glucose oxidase decorated graphene for cancer biomarker detection.
    Cheng Y; Yuan R; Chai Y; Niu H; Cao Y; Liu H; Bai L; Yuan Y
    Anal Chim Acta; 2012 Oct; 745():137-42. PubMed ID: 22938618
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Enhanced peroxydisulfate electrochemiluminescence for dopamine biosensing based on Au nanoparticle decorated reduced graphene oxide.
    Yan Y; Liu Q; Wang K; Jiang L; Yang X; Qian J; Dong X; Qiu B
    Analyst; 2013 Dec; 138(23):7101-6. PubMed ID: 24108062
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Efficient quenching of electrochemiluminescence from K-doped graphene-CdS:Eu NCs by G-quadruplex-hemin and target recycling-assisted amplification for ultrasensitive DNA biosensing.
    Zhou H; Zhang YY; Liu J; Xu JJ; Chen HY
    Chem Commun (Camb); 2013 Mar; 49(22):2246-8. PubMed ID: 23396566
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A biosensor for cholesterol based on gold nanoparticles-catalyzed luminol electrogenerated chemiluminescence.
    Zhang M; Yuan R; Chai Y; Chen S; Zhong H; Wang C; Cheng Y
    Biosens Bioelectron; 2012 Feb; 32(1):288-92. PubMed ID: 22206786
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fluorescent blood glucose monitor by hemin-functionalized graphene quantum dots based sensing system.
    He Y; Wang X; Sun J; Jiao S; Chen H; Gao F; Wang L
    Anal Chim Acta; 2014 Jan; 810():71-8. PubMed ID: 24439507
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An ultrasensitive luminol cathodic electrochemiluminescence immunosensor based on glucose oxidase and nanocomposites: graphene-carbon nanotubes and gold-platinum alloy.
    Jiang X; Chai Y; Yuan R; Cao Y; Chen Y; Wang H; Gan X
    Anal Chim Acta; 2013 Jun; 783():49-55. PubMed ID: 23726099
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Amplified electrochemiluminescence of luminol based on hybridization chain reaction and in situ generate co-reactant for highly sensitive immunoassay.
    Xiao L; Chai Y; Yuan R; Cao Y; Wang H; Bai L
    Talanta; 2013 Oct; 115():577-82. PubMed ID: 24054635
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A pseudo triple-enzyme cascade amplified aptasensor for thrombin detection based on hemin/G-quadruplex as signal label.
    Yi H; Xu W; Yuan Y; Bai L; Wu Y; Chai Y; Yuan R
    Biosens Bioelectron; 2014 Apr; 54():415-20. PubMed ID: 24296062
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.