These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
143 related articles for article (PubMed ID: 24563523)
1. Determination of 234U/238U, 235U/238U and 236U/238U isotope ratios in urine using sector field inductively coupled plasma mass spectrometry. Xiao G; Jones RL; Saunders D; Caldwell KL Radiat Prot Dosimetry; 2014 Dec; 162(4):618-24. PubMed ID: 24563523 [TBL] [Abstract][Full Text] [Related]
2. Determination of 238u/235u, 236u/238u and uranium concentration in urine using sf-icp-ms and mc-icp-ms: an interlaboratory comparison. Parrish RR; Thirlwall MF; Pickford C; Horstwood M; Gerdes A; Anderson J; Coggon D Health Phys; 2006 Feb; 90(2):127-38. PubMed ID: 16404170 [TBL] [Abstract][Full Text] [Related]
3. Determination of uranium isotopic composition and 236U content of soil samples and hot particles using inductively coupled plasma mass spectrometry. Boulyga SF; Becker JS Fresenius J Anal Chem; 2001 Jul; 370(5):612-7. PubMed ID: 11496994 [TBL] [Abstract][Full Text] [Related]
4. Determination of 235U and 238U in urine samples using sector field inductively coupled plasma mass spectrometry. Schramel P J Chromatogr B Analyt Technol Biomed Life Sci; 2002 Oct; 778(1-2):275-8. PubMed ID: 12376135 [TBL] [Abstract][Full Text] [Related]
5. Determining the isotopic compositions of uranium and fission products in radioactive environmental microsamples using laser ablation ICP-MS with multiple ion counters. Boulyga SF; Prohaska T Anal Bioanal Chem; 2008 Jan; 390(2):531-9. PubMed ID: 17874079 [TBL] [Abstract][Full Text] [Related]
6. Validated measurements of the uranium isotopic signature in human urine samples using magnetic sector-field inductively coupled plasma mass spectrometry. Tresl I; De Wannemacker G; Quétel CR; Petrov I; Vanhaecke F; Moens L; Taylor PD Environ Sci Technol; 2004 Jan; 38(2):581-6. PubMed ID: 14750735 [TBL] [Abstract][Full Text] [Related]
7. Flow-injection technique for determination of uranium and thorium isotopes in urine by inductively coupled plasma mass spectrometry. Benkhedda K; Epov VN; Evans RD Anal Bioanal Chem; 2005 Apr; 381(8):1596-603. PubMed ID: 15827719 [TBL] [Abstract][Full Text] [Related]
8. Uranium analysis in urine by inductively coupled plasma dynamic reaction cell mass spectrometry. Ejnik JW; Todorov TI; Mullick FG; Squibb K; McDiarmid MA; Centeno JA Anal Bioanal Chem; 2005 May; 382(1):73-9. PubMed ID: 15900454 [TBL] [Abstract][Full Text] [Related]
9. Method design and validation for the determination of uranium levels in human urine using high-resolution alpha spectrometry. Manickam E; Sdraulig S; Tinker RA J Environ Radioact; 2008 Mar; 99(3):491-501. PubMed ID: 17936457 [TBL] [Abstract][Full Text] [Related]
10. The quantitative analysis of uranium isotopes in the urine of the civilian population of eastern Afghanistan after Operation Enduring Freedom. Durakovic A Mil Med; 2005 Apr; 170(4):277-84. PubMed ID: 15916293 [TBL] [Abstract][Full Text] [Related]
11. Determination of depleted uranium in urine via isotope ratio measurements using large-bore direct injection high efficiency nebulizer-inductively coupled plasma mass spectrometry. Westphal CS; McLean JA; Hakspiel SJ; Jackson WE; McClain DE; Montaser A Appl Spectrosc; 2004 Sep; 58(9):1044-50. PubMed ID: 15479520 [TBL] [Abstract][Full Text] [Related]
12. Determination of extremely low (236)U/(238)U isotope ratios in environmental samples by sector-field inductively coupled plasma mass spectrometry using high-efficiency sample introduction. Boulyga SF; Heumann KG J Environ Radioact; 2006; 88(1):1-10. PubMed ID: 16504353 [TBL] [Abstract][Full Text] [Related]
13. Chemical Separation of Uranium and Precise Measurement of Veerasamy N; Takamasa A; Murugan R; Kasar S; Aono T; Inoue K; Fukushi M; Sahoo SK Molecules; 2020 May; 25(9):. PubMed ID: 32375226 [TBL] [Abstract][Full Text] [Related]
14. Isotopic composition and origin of uranium and plutonium in selected soil samples collected in Kosovo. Danesi PR; Bleise A; Burkart W; Cabianca T; Campbell MJ; Makarewicz M; Moreno J; Tuniz C; Hotchkis M J Environ Radioact; 2003; 64(2-3):121-31. PubMed ID: 12500799 [TBL] [Abstract][Full Text] [Related]
15. 234U/238U isotope ratios in groundwater from Southern Nevada: a comparison of alpha counting and magnetic sector ICP-MS. Cizdziel J; Farmer D; Hodge V; Lindley K; Stetzenbach K Sci Total Environ; 2005 Nov; 350(1-3):248-60. PubMed ID: 16227084 [TBL] [Abstract][Full Text] [Related]
16. Determination of the isotopic composition of uranium in urine by inductively coupled plasma mass spectrometry. Ejnik JW; Carmichael AJ; Hamilton MM; McDiarmid M; Squibb K; Boyd P; Tardiff W Health Phys; 2000 Feb; 78(2):143-6. PubMed ID: 10647980 [TBL] [Abstract][Full Text] [Related]
17. Rapid determination of uranium isotopes in urine by inductively coupled plasma-mass spectrometry. Shi Y; Dai X; Collins R; Kramer-Tremblay S Health Phys; 2011 Aug; 101(2):148-53. PubMed ID: 21709502 [TBL] [Abstract][Full Text] [Related]
18. Simultaneous Determination of Uranium and Depleted Uranium Isotopic Ratio Using Inductively Coupled Mass Spectrometry. Velez-Quinones MA; Xu H; Vo N; Gaitens JM; McDiarmid MA; Lewin-Smith MR; Strathmann FG Curr Protoc Toxicol; 2018 Nov; 78(1):e59. PubMed ID: 30286284 [TBL] [Abstract][Full Text] [Related]
19. Determination of (234)U/ (238)U isotope ratios in environmental waters by quadrupole ICP-MS after U stripping from alpha-spectrometry counting sources. Mas JL; Ma R; McLeod C; González-Labajo J; Cox A; Watson P Anal Bioanal Chem; 2006 Sep; 386(1):152-60. PubMed ID: 16868729 [TBL] [Abstract][Full Text] [Related]
20. Determination of natural and depleted uranium in urine at the ppt level: an interlaboratory analytical exercise. Ough EA; Lewis BJ; Andrews WS; Bennett LG; Hancock RG; D'Agastino PA Health Phys; 2006 May; 90(5):494-9. PubMed ID: 16607181 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]