These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 24567739)

  • 1. Customising PRESAGE
    Juang T; Newton J; Niebanck M; Benning R; Adamovics J; Oldham M
    J Phys Conf Ser; 2013; 444():012029. PubMed ID: 24567739
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development of a 3D remote dosimetry protocol compatible with MRgIMRT.
    Mein S; Rankine L; Adamovics J; Li H; Oldham M
    Med Phys; 2017 Nov; 44(11):6018-6028. PubMed ID: 28877344
    [TBL] [Abstract][Full Text] [Related]  

  • 3. On the feasibility of comprehensive high-resolution 3D remote dosimetry.
    Juang T; Grant R; Adamovics J; Ibbott G; Oldham M
    Med Phys; 2014 Jul; 41(7):071706. PubMed ID: 24989375
    [TBL] [Abstract][Full Text] [Related]  

  • 4. On the need for comprehensive validation of deformable image registration, investigated with a novel 3-dimensional deformable dosimeter.
    Juang T; Das S; Adamovics J; Benning R; Oldham M
    Int J Radiat Oncol Biol Phys; 2013 Oct; 87(2):414-21. PubMed ID: 23886417
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Preliminary investigation and application of a novel deformable PRESAGE
    Juang T; Newton J; Das S; Adamovics J; Oldham M
    J Phys Conf Ser; 2013; 444():12080. PubMed ID: 24454522
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Temperature dependence and temporal stability of stacked radiochromic sheets for three-dimensional dose verification.
    Liu K; Wang YF; Dona Lemus OM; Adamovics J; Wuu CS
    Med Phys; 2020 Nov; 47(11):5906-5918. PubMed ID: 32996168
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A Review of PRESAGE Radiochromic Polymer and the Compositions for Application in Radiotherapy Dosimetry.
    Mohyedin MZ; Zin HM; Adenan MZ; Abdul Rahman AT
    Polymers (Basel); 2022 Jul; 14(14):. PubMed ID: 35890665
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Characterization of a new radiochromic three-dimensional dosimeter.
    Guo PY; Adamovics JA; Oldham M
    Med Phys; 2006 May; 33(5):1338-45. PubMed ID: 16752569
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Experimental determination of the influence of oxygen on the PRESAGE® dosimeter.
    Alqathami M; Blencowe A; Ibbott G
    Phys Med Biol; 2016 Jan; 61(2):813-24. PubMed ID: 26732988
    [TBL] [Abstract][Full Text] [Related]  

  • 10. On the feasibility of polyurethane based 3D dosimeters with optical CT for dosimetric verification of low energy photon brachytherapy seeds.
    Adamson J; Yang Y; Juang T; Chisholm K; Rankine L; Adamovics J; Yin FF; Oldham M
    Med Phys; 2014 Jul; 41(7):071705. PubMed ID: 24989374
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A basic dosimetric study of PRESAGE: the effect of different amounts of fabricating components on the sensitivity and stability of the dosimeter.
    Mostaar A; Hashemi B; Zahmatkesh MH; Aghamiri SM; Mahdavi SR
    Phys Med Biol; 2010 Feb; 55(3):903-12. PubMed ID: 20071770
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An investigation of a PRESAGE® in vivo dosimeter for brachytherapy.
    Vidovic AK; Juang T; Meltsner S; Adamovics J; Chino J; Steffey B; Craciunescu O; Oldham M
    Phys Med Biol; 2014 Jul; 59(14):3893-905. PubMed ID: 24957850
    [TBL] [Abstract][Full Text] [Related]  

  • 13. WE-E-BRB-04: Quantitative Dose Tracking Enabled Through a Novel Deformable 3D Dosimeter.
    Juang T; Newton J; Das S; Adamovics J; Oldham M
    Med Phys; 2012 Jun; 39(6Part27):3956. PubMed ID: 28519995
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of methods for the measurement of radiation dose distributions in high dose rate (HDR) brachytherapy: Ge-doped optical fiber, EBT3 Gafchromic film, and PRESAGE® radiochromic plastic.
    Palmer AL; Di Pietro P; Alobaidli S; Issa F; Doran S; Bradley D; Nisbet A
    Med Phys; 2013 Jun; 40(6):061707. PubMed ID: 23718586
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A comprehensive evaluation of the PRESAGE/optical-CT 3D dosimetry system.
    Sakhalkar HS; Adamovics J; Ibbott G; Oldham M
    Med Phys; 2009 Jan; 36(1):71-82. PubMed ID: 19235375
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An investigation of PRESAGE® 3D dosimetry for IMRT and VMAT radiation therapy treatment verification.
    Jackson J; Juang T; Adamovics J; Oldham M
    Phys Med Biol; 2015 Mar; 60(6):2217-30. PubMed ID: 25683902
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Water equivalence evaluation of PRESAGE(®) formulations for megavoltage electron beams: a Monte Carlo study.
    Gorjiara T; Kuncic Z; Hill R; Adamovics J; Baldock C
    Australas Phys Eng Sci Med; 2012 Dec; 35(4):455-63. PubMed ID: 23299985
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Investigation of radiological properties and water equivalency of PRESAGE dosimeters.
    Gorjiara T; Hill R; Kuncic Z; Adamovics J; Bosi S; Kim JH; Baldock C
    Med Phys; 2011 Apr; 38(4):2265-74. PubMed ID: 21626961
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A practical three-dimensional dosimetry system for radiation therapy.
    Guo P; Adamovics J; Oldham M
    Med Phys; 2006 Oct; 33(10):3962-72. PubMed ID: 17089858
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Sensitivity and variability of Presage dosimeter formulations in sheet form with application to SBRT and SRS QA.
    Dumas M; Rakowski JT
    Med Phys; 2015 Dec; 42(12):7138-43. PubMed ID: 26632068
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.