BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 24579117)

  • 1. Biomechanically driven registration of pre- to intra-operative 3D images for laparoscopic surgery.
    Oktay O; Zhang L; Mansi T; Mountney P; Mewes P; Nicolau S; Soler L; Chefd'hotel C
    Med Image Comput Comput Assist Interv; 2013; 16(Pt 2):1-9. PubMed ID: 24579117
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An augmented reality framework for soft tissue surgery.
    Mountney P; Fallert J; Nicolau S; Soler L; Mewes PW
    Med Image Comput Comput Assist Interv; 2014; 17(Pt 1):423-31. PubMed ID: 25333146
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Pericardium based model fusion of CT and non-contrasted C-arm CT for visual guidance in cardiac interventions.
    Zheng Y
    Med Image Comput Comput Assist Interv; 2014; 17(Pt 2):700-7. PubMed ID: 25485441
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A method for registration of single photon emission computed tomography (SPECT) and computed tomography (CT) images for liver stereotactic radiotherapy (SRT).
    Gayou O; Day E; Mohammadi S; Kirichenko A
    Med Phys; 2012 Dec; 39(12):7398-401. PubMed ID: 23231289
    [TBL] [Abstract][Full Text] [Related]  

  • 5. 3D Physics-Based Registration of 2D Dynamic MRI Data.
    Trivisonne R; Peterlik I; Cotin S; Courtecuisse H
    Stud Health Technol Inform; 2016; 220():432-8. PubMed ID: 27046618
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fast elastic registration of soft tissues under large deformations.
    Peterlík I; Courtecuisse H; Rohling R; Abolmaesumi P; Nguan C; Cotin S; Salcudean S
    Med Image Anal; 2018 Apr; 45():24-40. PubMed ID: 29414434
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A review of 3D/2D registration methods for image-guided interventions.
    Markelj P; Tomaževič D; Likar B; Pernuš F
    Med Image Anal; 2012 Apr; 16(3):642-61. PubMed ID: 20452269
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Laparoscope self-calibration for robotic assisted minimally invasive surgery.
    Stoyanov D; Darzi A; Yang GZ
    Med Image Comput Comput Assist Interv; 2005; 8(Pt 2):114-21. PubMed ID: 16685950
    [TBL] [Abstract][Full Text] [Related]  

  • 9. 3-D/2-D registration by integrating 2-D information in 3-D.
    Tomazevic D; Likar B; Pernus F
    IEEE Trans Med Imaging; 2006 Jan; 25(1):17-27. PubMed ID: 16398411
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Phantom validation of coregistration of PET and CT for image-guided radiotherapy.
    Lavely WC; Scarfone C; Cevikalp H; Li R; Byrne DW; Cmelak AJ; Dawant B; Price RR; Hallahan DE; Fitzpatrick JM
    Med Phys; 2004 May; 31(5):1083-92. PubMed ID: 15191296
    [TBL] [Abstract][Full Text] [Related]  

  • 11. 3-D/2-D registration of CT and MR to X-ray images.
    Tomazevic D; Likar B; Slivnik T; Pernus F
    IEEE Trans Med Imaging; 2003 Nov; 22(11):1407-16. PubMed ID: 14606674
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Robust augmented reality registration method for localization of solid organs' tumors using CT-derived virtual biomechanical model and fluorescent fiducials.
    Kong SH; Haouchine N; Soares R; Klymchenko A; Andreiuk B; Marques B; Shabat G; Piechaud T; Diana M; Cotin S; Marescaux J
    Surg Endosc; 2017 Jul; 31(7):2863-2871. PubMed ID: 27796600
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Image guidance of intracardiac ultrasound with fusion of pre-operative images.
    Sun Y; Kadoury S; Li Y; John M; Resnick J; Plambeck G; Liao R; Sauer F; Xu C
    Med Image Comput Comput Assist Interv; 2007; 10(Pt 1):60-7. PubMed ID: 18051044
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Towards subject-specific models of the dynamic heart for image-guided mitral valve surgery.
    Linte CA; Wierzbicki M; Moore J; Little SH; Guiraudon GM; Peters TM
    Med Image Comput Comput Assist Interv; 2007; 10(Pt 2):94-101. PubMed ID: 18044557
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Interventional multidimodal hybrid unit: from pre-operative planning to immediate post-operative control].
    Scolozzi P; Schouman T
    Rev Stomatol Chir Maxillofac; 2012 Apr; 113(2):115-23. PubMed ID: 22398193
    [TBL] [Abstract][Full Text] [Related]  

  • 16. 3D/2D model-to-image registration applied to TIPS surgery.
    Jomier J; Bullitt E; Van Horn M; Pathak C; Aylward SR
    Med Image Comput Comput Assist Interv; 2006; 9(Pt 2):662-9. PubMed ID: 17354829
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optical techniques for 3D surface reconstruction in computer-assisted laparoscopic surgery.
    Maier-Hein L; Mountney P; Bartoli A; Elhawary H; Elson D; Groch A; Kolb A; Rodrigues M; Sorger J; Speidel S; Stoyanov D
    Med Image Anal; 2013 Dec; 17(8):974-96. PubMed ID: 23837969
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Scale-invariant registration of monocular endoscopic images to CT-scans for sinus surgery.
    Burschka D; Li M; Ishii M; Taylor RH; Hager GD
    Med Image Anal; 2005 Oct; 9(5):413-26. PubMed ID: 16009593
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Robust model-based 3d/3D fusion using sparse matching for minimally invasive surgery.
    Neumann D; Grbic S; John M; Navab N; Hornegger J; Ionasec R
    Med Image Comput Comput Assist Interv; 2013; 16(Pt 1):171-8. PubMed ID: 24505663
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Deformation-based augmented reality for hepatic surgery.
    Haouchine N; Dequidt J; Berger MO; Cotin S
    Stud Health Technol Inform; 2013; 184():182-8. PubMed ID: 23400153
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.