These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
117 related articles for article (PubMed ID: 24579373)
1. Specific absorption rate variation in a brain phantom due to exposure by a 3G mobile phone: problems in dosimetry. Behari J; Nirala JP Indian J Exp Biol; 2013 Dec; 51(12):1079-85. PubMed ID: 24579373 [TBL] [Abstract][Full Text] [Related]
2. SAR measurement due to mobile phone exposure in a simulated biological media. Behari J; Nirala JP Electromagn Biol Med; 2012 Sep; 31(3):195-203. PubMed ID: 22897400 [TBL] [Abstract][Full Text] [Related]
3. The estimation of 3D SAR distributions in the human head from mobile phone compliance testing data for epidemiological studies. Wake K; Varsier N; Watanabe S; Taki M; Wiart J; Mann S; Deltour I; Cardis E Phys Med Biol; 2009 Oct; 54(19):5695-706. PubMed ID: 19724098 [TBL] [Abstract][Full Text] [Related]
4. Effect of 3G cell phone exposure with computer controlled 2-D stepper motor on non-thermal activation of the hsp27/p38MAPK stress pathway in rat brain. Kesari KK; Meena R; Nirala J; Kumar J; Verma HN Cell Biochem Biophys; 2014 Mar; 68(2):347-58. PubMed ID: 23949848 [TBL] [Abstract][Full Text] [Related]
5. Analysis of three-dimensional SAR distributions emitted by mobile phones in an epidemiological perspective. Deltour I; Wiart J; Taki M; Wake K; Varsier N; Mann S; Schüz J; Cardis E Bioelectromagnetics; 2011 Dec; 32(8):634-43. PubMed ID: 21695709 [TBL] [Abstract][Full Text] [Related]
6. Dosimetric analysis of the carousel setup for the exposure of rats at 1.62 GHz. Schönborn F; Poković K; Kuster N Bioelectromagnetics; 2004 Jan; 25(1):16-26. PubMed ID: 14696049 [TBL] [Abstract][Full Text] [Related]
7. Interaction of mobile phones with superficial passive metallic implants. Virtanen H; Huttunen J; Toropainen A; Lappalainen R Phys Med Biol; 2005 Jun; 50(11):2689-700. PubMed ID: 15901963 [TBL] [Abstract][Full Text] [Related]
8. Dosimetric assessment of an exposure system for simulating GSM and WCDMA mobile phone usage. Bahr A; Dorn H; Bolz T Bioelectromagnetics; 2006 May; 27(4):320-7. PubMed ID: 16557502 [TBL] [Abstract][Full Text] [Related]
9. Analysis of the influence of handset phone position on RF exposure of brain tissue. Ghanmi A; Varsier N; Hadjem A; Conil E; Picon O; Wiart J Bioelectromagnetics; 2014 Dec; 35(8):568-79. PubMed ID: 25263784 [TBL] [Abstract][Full Text] [Related]
10. Analysis of mobile phone design features affecting radiofrequency power absorbed in a human head phantom. Kuehn S; Kelsh MA; Kuster N; Sheppard AR; Shum M Bioelectromagnetics; 2013 Sep; 34(6):479-88. PubMed ID: 23533135 [TBL] [Abstract][Full Text] [Related]
11. Setup and dosimetry for exposing anaesthetised pigs in vivo to 900 MHz GSM mobile phone fields. Toivonen T; Toivo T; Pitkäaho R; Puranen L; Silfverhuth M; Mennander A; Hannula M; Hyttinen J; Jokela K Bioelectromagnetics; 2008 Jul; 29(5):363-70. PubMed ID: 18247366 [TBL] [Abstract][Full Text] [Related]
12. FDTD chiral brain tissue model for specific absorption rate determination under radiation from mobile phones at 900 and 1800 MHz. Zamorano M; Torres-Silva H Phys Med Biol; 2006 Apr; 51(7):1661-72. PubMed ID: 16552096 [TBL] [Abstract][Full Text] [Related]
13. Electromagnetic absorption in the head of adults and children due to mobile phone operation close to the head. de Salles AA; Bulla G; Rodriguez CE Electromagn Biol Med; 2006; 25(4):349-60. PubMed ID: 17178592 [TBL] [Abstract][Full Text] [Related]
14. GFAP expression in the rat brain following sub-chronic exposure to a 900 MHz electromagnetic field signal. Ammari M; Gamez C; Lecomte A; Sakly M; Abdelmelek H; De Seze R Int J Radiat Biol; 2010 May; 86(5):367-75. PubMed ID: 20397841 [TBL] [Abstract][Full Text] [Related]
15. Estimation of head tissue-specific exposure from mobile phones based on measurements in the homogeneous SAM head. Gosselin MC; Kühn S; Crespo-Valero P; Cherubini E; Zefferer M; Christ A; Kuster N Bioelectromagnetics; 2011 Sep; 32(6):493-505. PubMed ID: 21416476 [TBL] [Abstract][Full Text] [Related]
16. Analysis of the effect of mobile phone base station antenna loading on localized SAR and its consequences for measurements. Hansson B; Thors B; Törnevik C Bioelectromagnetics; 2011 Dec; 32(8):664-72. PubMed ID: 21647933 [TBL] [Abstract][Full Text] [Related]
17. Impact of head morphology on local brain specific absorption rate from exposure to mobile phone radiation. Adibzadeh F; Bakker JF; Paulides MM; Verhaart RF; van Rhoon GC Bioelectromagnetics; 2015 Jan; 36(1):66-76. PubMed ID: 25399806 [TBL] [Abstract][Full Text] [Related]
18. 1439 MHz pulsed TDMA fields affect performance of rats in a T-maze task only when body temperature is elevated. Yamaguchi H; Tsurita G; Ueno S; Watanabe S; Wake K; Taki M; Nagawa H Bioelectromagnetics; 2003 May; 24(4):223-30. PubMed ID: 12696082 [TBL] [Abstract][Full Text] [Related]
19. Empirical and theoretical dosimetry in support of whole body radio frequency (RF) exposure in seated human volunteers at 220 MHz. Allen SJ; Adair ER; Mylacraine KS; Hurt W; Ziriax J Bioelectromagnetics; 2005 Sep; 26(6):440-7. PubMed ID: 15931686 [TBL] [Abstract][Full Text] [Related]
20. Determination of safety distance limits for a human near a cellular base station antenna, adopting the IEEE standard or ICNIRP guidelines. Cooper J; Marx B; Buhl J; Hombach V Bioelectromagnetics; 2002 Sep; 23(6):429-43. PubMed ID: 12210561 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]