409 related articles for article (PubMed ID: 24581458)
21. Predictive factors of diagnostic accuracy of CT-guided transthoracic fine-needle aspiration for solid noncalcified, subsolid and mixed pulmonary nodules.
De Filippo M; Saba L; Concari G; Nizzoli R; Ferrari L; Tiseo M; Ardizzoni A; Sverzellati N; Paladini I; Ganazzoli C; Sconfienza LM; Carrafiello G; Brunese L; Genovese EA; Ampollini L; Carbognani P; Rusca M; Zompatori M; Rossi C
Radiol Med; 2013 Oct; 118(7):1071-81. PubMed ID: 23856805
[TBL] [Abstract][Full Text] [Related]
22. Trans-organ versus trans-mesenteric computed tomography-guided percutaneous fine-needle aspiration biopsy of pancreatic masses: feasibility and safety.
Hsu MY; Pan KT; Chen CM; Lui KW; Chu SY; Hung CF; Huang YT; Tseng JH
Clin Radiol; 2014 Oct; 69(10):1050-5. PubMed ID: 25110300
[TBL] [Abstract][Full Text] [Related]
23. Diagnostic performance of CT-guided percutaneous transthoracic core needle biopsy using low tube voltage (100 kVp): comparison with conventional tube voltage (120 kVp).
Lee HN; Lee SM; Choe J; Lee SM; Chae EJ; Do KH; Seo JB
Acta Radiol; 2018 Apr; 59(4):425-433. PubMed ID: 28691525
[TBL] [Abstract][Full Text] [Related]
24. Diagnostic accuracy and complication rate of image-guided percutaneous transthoracic needle lung biopsy for subsolid pulmonary nodules: a systematic review and meta-analysis.
Kim J; Chee CG; Cho J; Kim Y; Yoon MA
Br J Radiol; 2021 Nov; 94(1127):20210065. PubMed ID: 34662206
[TBL] [Abstract][Full Text] [Related]
25. Comparison of lung lesion biopsies between low-dose CT-guided and conventional CT-guided techniques.
Meng XX; Kuai XP; Dong WH; Jia NY; Liu SY; Xiao XS
Acta Radiol; 2013 Oct; 54(8):909-15. PubMed ID: 23817682
[TBL] [Abstract][Full Text] [Related]
26. Diagnostic performance of percutaneous core needle lung biopsy under multi-CT fluoroscopic guidance for ground-glass opacity pulmonary lesions.
Yamauchi Y; Izumi Y; Nakatsuka S; Inoue M; Hayashi Y; Mukai M; Nomori H
Eur J Radiol; 2011 Aug; 79(2):e85-9. PubMed ID: 21515009
[TBL] [Abstract][Full Text] [Related]
27. Does biopsy needle traversing through central portion of lesion increase the risk of hemoptysis during percutaneous transthoracic needle biopsy?
Chen CH; Huang WM; Liang SH; Jhou ZY; Chen CW; Chien YC; Lin HC; Wang CH; Huang CC; Liao WN; Huang CY
Jpn J Radiol; 2018 Mar; 36(3):231-237. PubMed ID: 29352406
[TBL] [Abstract][Full Text] [Related]
28. Percutaneous CT-guided fine-needle aspiration of pulmonary lesions: Results and complications in 409 patients.
Laspas F; Roussakis A; Efthimiadou R; Papaioannou D; Papadopoulos S; Andreou J
J Med Imaging Radiat Oncol; 2008 Oct; 52(5):458-62. PubMed ID: 19032391
[TBL] [Abstract][Full Text] [Related]
29. Imaging-histologic discordance at percutaneous biopsy of the lung.
Oh AS; Arnold CW; Vangala S; Wallace WD; Genshaft SJ; Sarma K; Aberle DR
Acad Radiol; 2015 Apr; 22(4):481-7. PubMed ID: 25601302
[TBL] [Abstract][Full Text] [Related]
30. Image-guided ovarian mass biopsy: efficacy and safety.
Thabet A; Somarouthu B; Oliva E; Gervais DA; Hahn PF; Lee SI
J Vasc Interv Radiol; 2014 Dec; 25(12):1922-1927.e1. PubMed ID: 25241300
[TBL] [Abstract][Full Text] [Related]
31. Percutaneous CT-guided aspiration and core biopsy of pulmonary nodules smaller than 1 cm: analysis of outcomes of 305 procedures from a tertiary referral center.
Choi SH; Chae EJ; Kim JE; Kim EY; Oh SY; Hwang HJ; Lee HJ
AJR Am J Roentgenol; 2013 Nov; 201(5):964-70. PubMed ID: 24147465
[TBL] [Abstract][Full Text] [Related]
32. Extrapleural paravertebral CT guided fine needle biopsy of subcarinal lymph nodes.
Tantawy WH; El-Gemeie EH; Ibrahim AS; Mohamed MA
Eur J Radiol; 2012 Oct; 81(10):2907-12. PubMed ID: 22154602
[TBL] [Abstract][Full Text] [Related]
33. Diagnostic accuracy of CT fluoroscopy-guided needle aspiration biopsy of ground-glass opacity pulmonary lesions.
Hur J; Lee HJ; Nam JE; Kim YJ; Kim TH; Choe KO; Choi BW
AJR Am J Roentgenol; 2009 Mar; 192(3):629-34. PubMed ID: 19234257
[TBL] [Abstract][Full Text] [Related]
34. C-arm cone-beam CT-guided percutaneous transthoracic lung biopsy: usefulness in evaluation of small pulmonary nodules.
Hwang HS; Chung MJ; Lee JW; Shin SW; Lee KS
AJR Am J Roentgenol; 2010 Dec; 195(6):W400-7. PubMed ID: 21098171
[TBL] [Abstract][Full Text] [Related]
35. CT-guided biopsy of lesions of the lung, liver, pancreas or of enlarged lymph nodes: value of additional fine needle aspiration (FNA) to core needle biopsy (CNB) in an offsite pathologist setting.
Schoellnast H; Komatz G; Bisail H; Talakic E; Fauster M; Ehammer T; Quehenberger F; Schaffler GJ
Acad Radiol; 2010 Oct; 17(10):1275-81. PubMed ID: 20621527
[TBL] [Abstract][Full Text] [Related]
36. Transthoracic needle aspiration biopsy for the cytologic diagnosis of subsolid lung nodules.
Klein JS
Cancer Cytopathol; 2016 Jul; 124(7):451-2. PubMed ID: 26990028
[No Abstract] [Full Text] [Related]
37. Additional value of CT-fluoroscopic biopsy of pulmonary lesions: a retrospective study of 69 patients.
Bladt O; De Wever W
JBR-BTR; 2006; 89(6):298-302. PubMed ID: 17274583
[TBL] [Abstract][Full Text] [Related]
38. Diagnostic accuracy and complication rate of CT-guided fine needle aspiration biopsy of lung lesions: a study based on the experience of the cytopathologist.
Priola AM; Priola SM; Cataldi A; Di Franco M; Pazè F; Marci V; Berruti A
Acta Radiol; 2010 Jun; 51(5):527-33. PubMed ID: 20429755
[TBL] [Abstract][Full Text] [Related]
39. Combining fine-needle aspiration and core biopsy under CT fluoroscopy guidance: a better way to treat patients with lung nodules?
Yamagami T; Iida S; Kato T; Tanaka O; Nishimura T
AJR Am J Roentgenol; 2003 Mar; 180(3):811-5. PubMed ID: 12591702
[TBL] [Abstract][Full Text] [Related]
40. Current role of computed tomography-guided transthoracic needle biopsy of metastatic lung lesions.
Galluzzo A; Genova C; Dioguardi S; Midiri M; Cajozzo M
Future Oncol; 2015; 11(2 Suppl):43-6. PubMed ID: 25662328
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]