250 related articles for article (PubMed ID: 24582180)
1. The incidence of coring with blunt versus sharp needles.
Wani T; Wadhwa A; Tobias JD
J Clin Anesth; 2014 Mar; 26(2):152-4. PubMed ID: 24582180
[TBL] [Abstract][Full Text] [Related]
2. Occurrence of coring after needle insertion through a rubber stopper: study with prednisolone acetate.
Campagna R; Pessis E; Guerini H; Feydy A; Drapé JL
Eur Radiol; 2013 Feb; 23(2):424-7. PubMed ID: 22865273
[TBL] [Abstract][Full Text] [Related]
3. Occurrence of coring in insulin vials and possibility of rubber piece contamination by self-injection.
Asakura T; Seino H; Nozaki S; Abe R
Yakugaku Zasshi; 2001 Jun; 121(6):459-63. PubMed ID: 11433780
[TBL] [Abstract][Full Text] [Related]
4. The impact of needle size and angle on rubber coring after multiple puncturing of multi-dose propofol vial rubber stoppers.
Chotikawanich T; Kammee T; Khantee S
Heliyon; 2022 May; 8(5):e09389. PubMed ID: 35592659
[TBL] [Abstract][Full Text] [Related]
5. The incidence of coring and fragmentation of medication vial rubber stoppers.
Eskander J; Cotte J; Glenn E; Friedman S; Rosinia F
J Clin Anesth; 2015 Aug; 27(5):442-4. PubMed ID: 25910529
[No Abstract] [Full Text] [Related]
6. [A case of the foreign body due to "coring"].
Sakai T; Koh H; Matsuki A
Masui; 1996 Dec; 45(12):1533-5. PubMed ID: 8997059
[TBL] [Abstract][Full Text] [Related]
7. Adsorption of (99m)Tc-radiopharmaceuticals onto injection vials and syringes.
Mushtaq A; Ur Rehman T; Safdar Mansur M; Jehangir M
J Nucl Med Technol; 2008 Jun; 36(2):91-4. PubMed ID: 18483140
[TBL] [Abstract][Full Text] [Related]
8. Avoiding unconscious injection of vial-derived rubber particles during intra-articular drug administration.
Hecker A; Di Maro A; Liechti EF; Klenke FM
Osteoarthr Cartil Open; 2021 Jun; 3(2):100164. PubMed ID: 36474986
[TBL] [Abstract][Full Text] [Related]
9. Self-sealing capacity of vial stoppers after multiple needle punctures.
Ponto JA
J Am Pharm Assoc (2003); 2013; 53(1):58-60. PubMed ID: 23636157
[TBL] [Abstract][Full Text] [Related]
10. A recommended solution for avoiding coring of a rubber stopper.
Adachi YU; Suzuki K; Itagaki T; Obata Y; Doi M; Sato S
Anesth Analg; 2008 Sep; 107(3):1084; author reply 1084-5. PubMed ID: 18713937
[No Abstract] [Full Text] [Related]
11. Coring: a potential problem in eye surgery.
Stein HA; Vu BL
J Cataract Refract Surg; 1994 Mar; 20(2):169-71. PubMed ID: 8201568
[TBL] [Abstract][Full Text] [Related]
12. Hepatitis C Contamination of Medication Vials Accessed with Sterile Needles and Syringes.
van Vlymen JM; Magnus J; Jaeger M; Breton S; Taylor NG; Phelan R; Sagan SM
Anesthesiology; 2019 Aug; 131(2):305-314. PubMed ID: 31166244
[TBL] [Abstract][Full Text] [Related]
13. The incidence of propofol vial coring with blunt needle use is reduced with angled puncture compared with perpendicular puncture.
Gragasin FS; van den Heever ZA
Anesth Analg; 2015 Apr; 120(4):954-5. PubMed ID: 25790214
[No Abstract] [Full Text] [Related]
14. [Study on particle contamination produced by syringe needles and rubber stoppers for pharmaceutical solutions].
Zhao L; Wang HS; Han ZF
Zhonghua Hu Li Za Zhi; 1997 Jan; 32(1):12-4. PubMed ID: 9304949
[TBL] [Abstract][Full Text] [Related]
15. Vial Coring.
Patel J; Smith CC
Pain Med; 2019 Sep; 20(9):1841-1842. PubMed ID: 31184365
[No Abstract] [Full Text] [Related]
16. Natural rubber pharmaceutical vial closures release latex allergens that produce skin reactions.
Primeau MN; Adkinson NF; Hamilton RG
J Allergy Clin Immunol; 2001 Jun; 107(6):958-62. PubMed ID: 11398071
[TBL] [Abstract][Full Text] [Related]
17. Container/Closure Integrity Testing and the Identification of a Suitable Vial/Stopper Combination for Low-Temperature Storage at -80 {degrees}C.
Zuleger B; Werner U; Kort A; Glowienka R; Wehnes E; Duncan D
PDA J Pharm Sci Technol; 2012; 66(5):453-65. PubMed ID: 23035029
[TBL] [Abstract][Full Text] [Related]
18. [A case of coring on using a 1% Diprivan vial].
Adachi Y; Takigami J; Watanabe K; Satoh T
Masui; 2001 Jun; 50(6):635-6. PubMed ID: 11452471
[TBL] [Abstract][Full Text] [Related]
19. Sharp versus blunt needle: a comparative study of penetration of internal structures and bleeding in dogs.
Heavner JE; Racz GB; Jenigiri B; Lehman T; Day MR
Pain Pract; 2003 Sep; 3(3):226-31. PubMed ID: 17147672
[TBL] [Abstract][Full Text] [Related]
20. Defining unnecessary disinfection procedures for single-dose and multiple-dose vials.
Buckley T; Dudley SM; Donowitz LG
Am J Crit Care; 1994 Nov; 3(6):448-51. PubMed ID: 7834004
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]