These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

374 related articles for article (PubMed ID: 24583159)

  • 41. Influence of Ru on structure and corrosion behavior of passive film on Ti-6Al-4V alloy in oil and gas exploration conditions.
    Liu Q; Liu H; Xie J; Zhang WF; Zhang YM; Feng C; Li GS; Yu Y; Song SY; Yin CX
    Sci Rep; 2022 Oct; 12(1):16586. PubMed ID: 36198740
    [TBL] [Abstract][Full Text] [Related]  

  • 42. The electrochemical behavior and surface analysis of Ti50Ni47.2Co2.8 alloy for orthodontic use.
    Wang QY; Zheng YF
    Dent Mater; 2008 Sep; 24(9):1207-11. PubMed ID: 18336899
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Microstructure and mechanical behavior of superelastic Ti-24Nb-0.5O and Ti-24Nb-0.5N biomedical alloys.
    Ramarolahy A; Castany P; Prima F; Laheurte P; Péron I; Gloriant T
    J Mech Behav Biomed Mater; 2012 May; 9():83-90. PubMed ID: 22498286
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Design of a nitrogen-implanted titanium-based superelastic alloy with optimized properties for biomedical applications.
    Gordin DM; Busardo D; Cimpean A; Vasilescu C; Höche D; Drob SI; Mitran V; Cornen M; Gloriant T
    Mater Sci Eng C Mater Biol Appl; 2013 Oct; 33(7):4173-82. PubMed ID: 23910330
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Enhanced osteoblast proliferation and corrosion resistance of commercially pure titanium through surface nanostructuring by ultrasonic shot peening and stress relieving.
    Jindal S; Bansal R; Singh BP; Pandey R; Narayanan S; Wani MR; Singh V
    J Oral Implantol; 2014 Jul; 40 Spec No():347-55. PubMed ID: 25020216
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Comparative investigations of
    Liu X; Niu Y; Xie W; Wei D; Du Q
    RSC Adv; 2020 Jun; 10(40):23582-23591. PubMed ID: 35517345
    [TBL] [Abstract][Full Text] [Related]  

  • 47. MRI-compatible Nb-60Ta-2Zr alloy for vascular stents: Electrochemical corrosion behavior in simulated plasma solution.
    Li HZ; Zhao X; Xu J
    Mater Sci Eng C Mater Biol Appl; 2015 Nov; 56():205-14. PubMed ID: 26249582
    [TBL] [Abstract][Full Text] [Related]  

  • 48. The Influence of Microstructure on the Passive Layer Chemistry and Corrosion Resistance for Some Titanium-Based Alloys.
    El-Bagoury N; Ahmed SI; Ahmed Abu Ali O; El-Hadad S; Fallatah AM; Mersal GAM; Ibrahim MM; Wysocka J; Ryl J; Boukherroub R; A Amin M
    Materials (Basel); 2019 Apr; 12(8):. PubMed ID: 30991704
    [TBL] [Abstract][Full Text] [Related]  

  • 49. In vitro biocompatibility, mechanical properties, and corrosion resistance of Ti-Zr-Nb-Ta-Pd and Ti-Sn-Nb-Ta-Pd alloys.
    Ito A; Okazaki Y; Tateishi T; Ito Y
    J Biomed Mater Res; 1995 Jul; 29(7):893-9. PubMed ID: 7593029
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Electrochemical studies of the corrosion behaviour of titanium and the Ti-6Al-4V alloy using electrochemical impedance spectroscopy.
    Grosgogeat B; Boinet M; Dalard F; Lissac M
    Biomed Mater Eng; 2004; 14(3):323-31. PubMed ID: 15299244
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Strengthening mechanism and corrosion resistance of beta-type Ti-Nb-Zr-Mn alloys.
    Jawed SF; Rabadia CD; Liu YJ; Wang LQ; Qin P; Li YH; Zhang XH; Zhang LC
    Mater Sci Eng C Mater Biol Appl; 2020 May; 110():110728. PubMed ID: 32204038
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Electrochemical impedance spectroscopy study of Ti-6Al-4V alloy in artificial saliva with fluoride and/or bovine albumin.
    Huang HH; Lee TH
    Dent Mater; 2005 Aug; 21(8):749-55. PubMed ID: 15878783
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Controlling the degradation rate of AZ91 magnesium alloy via sol-gel derived nanostructured hydroxyapatite coating.
    Rojaee R; Fathi M; Raeissi K
    Mater Sci Eng C Mater Biol Appl; 2013 Oct; 33(7):3817-25. PubMed ID: 23910282
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Stability of cp-Ti and Ti-6Al-4V alloy for dental implants as a function of saliva pH - an electrochemical study.
    Barão VA; Mathew MT; Assunção WG; Yuan JC; Wimmer MA; Sukotjo C
    Clin Oral Implants Res; 2012 Sep; 23(9):1055-62. PubMed ID: 22092540
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Microstructure, surface characterization and long-term stability of new quaternary Ti-Zr-Ta-Ag alloy for implant use.
    Vasilescu C; Osiceanu P; Moreno JMC; Drob SI; Preda S; Popa M; Dan I; Marcu M; Prodana M; Popovici IA; Ionita D; Vasilescu E
    Mater Sci Eng C Mater Biol Appl; 2017 Feb; 71():322-334. PubMed ID: 27987714
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Comparison of the osteoblastic activity of low elastic modulus Ti-24Nb-4Zr-8Sn alloy and pure titanium modified by physical and chemical methods.
    Zhan X; Li S; Cui Y; Tao A; Wang C; Li H; Zhang L; Yu H; Jiang J; Li C
    Mater Sci Eng C Mater Biol Appl; 2020 Aug; 113():111018. PubMed ID: 32487417
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Development and properties of Ti-In binary alloys as dental biomaterials.
    Wang QY; Wang YB; Lin JP; Zheng YF
    Mater Sci Eng C Mater Biol Appl; 2013 Apr; 33(3):1601-6. PubMed ID: 23827613
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Microstructure and in vitro degradation performance of Mg-Zn-Mn alloys for biomedical application.
    Rosalbino F; De Negri S; Scavino G; Saccone A
    J Biomed Mater Res A; 2013 Mar; 101(3):704-11. PubMed ID: 22941918
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials.
    Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM
    J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Admicellar polymerization and characterization of thin poly(2,2,2-trifluoroethyl acrylate) film on aluminum alloys for in-crevice corrosion control.
    Le DV; Kendrick MM; O'Rear EA
    Langmuir; 2004 Aug; 20(18):7802-10. PubMed ID: 15323534
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 19.