These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
62. The effect of mucine, IgA, urea, and lysozyme on the corrosion behavior of various non-precious dental alloys and pure titanium in artificial saliva. Bilhan H; Bilgin T; Cakir AF; Yuksel B; Von Fraunhofer JA J Biomater Appl; 2007 Nov; 22(3):197-221. PubMed ID: 17255155 [TBL] [Abstract][Full Text] [Related]
63. Passive films on metallic biomaterials under simulated physiological conditions. Pound BG J Biomed Mater Res A; 2014 May; 102(5):1595-604. PubMed ID: 23666913 [TBL] [Abstract][Full Text] [Related]
64. Surface characteristics and electrochemical corrosion behavior of a pre-anodized microarc oxidation coating on titanium alloy. Cui WF; Jin L; Zhou L Mater Sci Eng C Mater Biol Appl; 2013 Oct; 33(7):3775-9. PubMed ID: 23910276 [TBL] [Abstract][Full Text] [Related]
65. Corrosion behaviour and surface analysis of a Co-Cr and two Ni-Cr dental alloys before and after simulated porcelain firing. Qiu J; Yu WQ; Zhang FQ; Smales RJ; Zhang YL; Lu CH Eur J Oral Sci; 2011 Feb; 119(1):93-101. PubMed ID: 21244518 [TBL] [Abstract][Full Text] [Related]
66. EIS Characterization of Ti Alloys in Relation to Alloying Additions of Ta. Socorro-Perdomo PP; Florido-Suárez NR; Mirza-Rosca JC; Saceleanu MV Materials (Basel); 2022 Jan; 15(2):. PubMed ID: 35057194 [TBL] [Abstract][Full Text] [Related]
67. Properties of hydroxyapatite-coated Ti-6Al-4V alloy produced by the ion-plating method. Yoshinari M; Ozeki K; Sumii T Bull Tokyo Dent Coll; 1991 Nov; 32(4):147-56. PubMed ID: 1668076 [TBL] [Abstract][Full Text] [Related]
68. Corrosion Behavior of Nitrided Layer of Ti6Al4V Titanium Alloy by Hollow Cathodic Plasma Source Nitriding. Zhang L; Shao M; Zhang Z; Yi X; Yan J; Zhou Z; Fang D; He Y; Li Y Materials (Basel); 2023 Apr; 16(8):. PubMed ID: 37109798 [TBL] [Abstract][Full Text] [Related]
69. Corrosion resistance of stressed NiTi and stainless steel orthodontic wires in acid artificial saliva. Huang HH J Biomed Mater Res A; 2003 Sep; 66(4):829-39. PubMed ID: 12926035 [TBL] [Abstract][Full Text] [Related]
70. Galvanic corrosion behavior of orthodontic archwire alloys coupled to bracket alloys. Iijima M; Endo K; Yuasa T; Ohno H; Hayashi K; Kakizaki M; Mizoguchi I Angle Orthod; 2006 Jul; 76(4):705-11. PubMed ID: 16808581 [TBL] [Abstract][Full Text] [Related]
71. Improving the corrosion resistance of Mg-4.0Zn-0.2Ca alloy by micro-arc oxidation. Xia YH; Zhang BP; Lu CX; Geng L Mater Sci Eng C Mater Biol Appl; 2013 Dec; 33(8):5044-50. PubMed ID: 24094222 [TBL] [Abstract][Full Text] [Related]
72. Graphene nanocoating provides superb long-lasting corrosion protection to titanium alloy. Malhotra R; Han Y; Nijhuis CA; Silikas N; Castro Neto AH; Rosa V Dent Mater; 2021 Oct; 37(10):1553-1560. PubMed ID: 34420797 [TBL] [Abstract][Full Text] [Related]
73. Corrosion Passivation in Simulated Body Fluid of Ti-Zr-Ta-xSn Alloys as Biomedical Materials. Sherif EM; Bahri YA; Alharbi HF; Ijaz MF Materials (Basel); 2023 Jun; 16(13):. PubMed ID: 37444917 [TBL] [Abstract][Full Text] [Related]
74. Surface modification of Ni-Ti alloys for stent application after magnetoelectropolishing. Gill P; Musaramthota V; Munroe N; Datye A; Dua R; Haider W; McGoron A; Rokicki R Mater Sci Eng C Mater Biol Appl; 2015 May; 50():37-44. PubMed ID: 25746243 [TBL] [Abstract][Full Text] [Related]
75. Electrochemical comparison and biological performance of a new CoCrNbMoZr alloy with commercial CoCrMo alloy. Andrei M; Galateanu B; Hudita A; Costache M; Osiceanu P; Calderon Moreno JM; Drob SI; Demetrescu I Mater Sci Eng C Mater Biol Appl; 2016 Feb; 59():346-355. PubMed ID: 26652383 [TBL] [Abstract][Full Text] [Related]
76. Strontium-Loaded Nanotubes of Ti-24Nb-4Zr-8Sn Alloys for Biomedical Implantation. Liu F; Wang X; Li S; Liao Y; Zhan X; Tao A; Zheng F; Li H; Su Y; Jiang J; Li C J Biomed Nanotechnol; 2021 Sep; 17(9):1812-1823. PubMed ID: 34688326 [TBL] [Abstract][Full Text] [Related]
77. Novel Ti-Nb alloys with improved wear resistance for biomedical implant application. Chapala P; Acharyya SG; Shariff SM; Naik G Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():4208-4211. PubMed ID: 28269211 [TBL] [Abstract][Full Text] [Related]
78. Evolution of the passive film on mechanically damaged nitinol. Schroeder V J Biomed Mater Res A; 2009 Jul; 90(1):1-17. PubMed ID: 18481784 [TBL] [Abstract][Full Text] [Related]
79. Surface Characterization, Corrosion Resistance and in Vitro Biocompatibility of a New Ti-Hf-Mo-Sn Alloy. Ion R; Drob SI; Ijaz MF; Vasilescu C; Osiceanu P; Gordin DM; Cimpean A; Gloriant T Materials (Basel); 2016 Oct; 9(10):. PubMed ID: 28773939 [TBL] [Abstract][Full Text] [Related]
80. The influence of niobium and vanadium on passivity of titanium-based implants in physiological solution. Metikos-Huković M; Kwokal A; Piljac J Biomaterials; 2003 Sep; 24(21):3765-75. PubMed ID: 12818549 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]