These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 24585245)

  • 1. [Water-cooled laser sealing of lung tissue in an ex-vivo ventilated porcine lung model].
    Tonoyan T; Prisadov G; Menges P; Herrmann K; Bobrov P; Linder A
    Zentralbl Chir; 2014 Jun; 139(3):329-34. PubMed ID: 24585245
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Laser resection of lung tissue: heat accumulation from adjacent laser application and how to cool it down.
    Kirschbaum A; Rexin P; Pehl A; Bartsch D; Quint K
    Thorac Cardiovasc Surg; 2014 Jun; 62(4):363-8. PubMed ID: 24297634
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Use of an electrothermal bipolar tissue sealing system in lung surgery.
    Santini M; Vicidomini G; Baldi A; Gallo G; Laperuta P; Busiello L; Di Marino MP; Pastore V
    Eur J Cardiothorac Surg; 2006 Feb; 29(2):226-30. PubMed ID: 16376100
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Hemostasis and sealing of air leaks in the lung using high-intensity focused ultrasound.
    Vaezy S; Zderic V; Karmy-Jones R; Jurkovich GJ; Cornejo C; Martin RW
    J Trauma; 2007 Jun; 62(6):1390-5. PubMed ID: 17563654
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Infrared laser sealing of porcine vascular tissues using a 1,470 nm diode laser: Preliminary in vivo studies.
    Cilip CM; Kerr D; Latimer CA; Rosenbury SB; Giglio NC; Hutchens TC; Nau WH; Fried NM
    Lasers Surg Med; 2017 Apr; 49(4):366-371. PubMed ID: 27785787
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Predicting clinical efficacy of photoangiolytic and cutting/ablating lasers using the chick chorioallantoic membrane model: implications for endoscopic voice surgery.
    Burns JA; Kobler JB; Heaton JT; Anderson RR; Zeitels SM
    Laryngoscope; 2008 Jun; 118(6):1109-24. PubMed ID: 18354337
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Harmonic technology versus neodymium-doped yttrium aluminium garnet laser and electrocautery for lung metastasectomy: an experimental study.
    Fiorelli A; Accardo M; Carelli E; Del Prete A; Messina G; Reginelli A; Berritto D; Papale F; Armenia E; Chiodini P; Grassi R; Santini M
    Interact Cardiovasc Thorac Surg; 2016 Jul; 23(1):47-56. PubMed ID: 27006181
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pneumostasis of experimental air leaks with a new photopolymerized synthetic tissue sealant.
    Ranger WR; Halpin D; Sawhney AS; Lyman M; Locicero J
    Am Surg; 1997 Sep; 63(9):788-95. PubMed ID: 9290523
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Bipolar impedance-controlled sealing of the pulmonary artery with SealSafe G3 electric current: determination of bursting pressures in an ex vivo model.
    Kirschbaum A; Kunz J; Steinfeldt T; Pehl A; Meyer C; Bartsch DK
    J Surg Res; 2014 Dec; 192(2):611-5. PubMed ID: 25128924
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Novel Image-Guided Percutaneous Lung Tissue Excision Device With Integrated Sealing of Blood Vessels and Airways: An In Vivo Preclinical Study.
    Salazar JE; Fischel R; Bueche KM; Samra K; Gonzalez L; Nathan JC; Lu C; Rodriguez J; Nguyen S; Cohn WE; Boyle E
    Innovations (Phila); 2024; 19(2):143-149. PubMed ID: 38504149
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Subsurface tissue lesions created using an Nd:YAG laser and a sapphire contact cooling probe.
    Ramli R; Chung CC; Fried NM; Franco N; Hayman MH
    Lasers Surg Med; 2004; 35(5):392-6. PubMed ID: 15611957
    [TBL] [Abstract][Full Text] [Related]  

  • 12. New applications of the laser in pulmonary surgery: hemostasis and sealing of air leaks.
    LoCicero J; Hartz RS; Frederiksen JW; Michaelis LL
    Ann Thorac Surg; 1985 Dec; 40(6):546-50. PubMed ID: 3935067
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Simultaneous sealing and bisection of porcine renal blood vessels, ex vivo, using a continuous-wave, infrared diode laser at 1470 nm.
    Saeed WM; Yoshino JK; Traynham AJ; Fried NM
    Lasers Med Sci; 2024 Jun; 39(1):161. PubMed ID: 38907065
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Infrared laser thermal fusion of blood vessels: preliminary ex vivo tissue studies.
    Cilip CM; Rosenbury SB; Giglio N; Hutchens TC; Schweinsberger GR; Kerr D; Latimer C; Nau WH; Fried NM
    J Biomed Opt; 2013 May; 18(5):58001. PubMed ID: 23640080
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of a novel electrosurgical sealing mode in an ex vivo and in vivo porcine model.
    Thiel K; Linzenbold W; Enderle MD; Nold B; Königsrainer A; Schenk M; Thiel C
    Surg Endosc; 2018 Mar; 32(3):1456-1463. PubMed ID: 28924734
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Local lung coagulation post resection: an ex-vivo porcine model.
    Kirschbaum A; Surowiec TM; Pehl A; Wiesmann T; Bartsch DK; Mirow N
    Lasers Med Sci; 2022 Feb; 37(1):443-447. PubMed ID: 33759033
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The Effect of Cooling Fluid Composition on Ablation Size in Hepatic Laser Ablation: A Comparative Study in an Ex Vivo Bovine Setting.
    Mankertz F; Bayerl N; Gemeinhardt O; Hosten N; Kromrey ML
    Tomography; 2023 Sep; 9(5):1638-1648. PubMed ID: 37736984
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Laser-induced thermotherapy (LITT) of lung metastases: description of a miniaturized applicator, optimization, and initial treatment of patients].
    Hosten N; Stier A; Weigel C; Kirsch M; Puls R; Nerger U; Jahn D; Stroszczynski C; Heidecke CD; Speck U
    Rofo; 2003 Mar; 175(3):393-400. PubMed ID: 12635017
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Diode laser-induced tissue effects: in vitro tissue model study and in vivo evaluation of wound healing following non-contact application.
    Havel M; Betz CS; Leunig A; Sroka R
    Lasers Surg Med; 2014 Aug; 46(6):449-55. PubMed ID: 24839034
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Implementation of a novel efficacy score to compare sealing and cutting devices in a porcine model.
    Brecht L; Wallwiener M; Schott S; Domschke C; Dinkic C; Golatta M; Schuetz F; Fluhr H; Stenzinger A; Kirchner M; Sohn C; Rom J
    Surg Endosc; 2018 Feb; 32(2):1002-1011. PubMed ID: 28840380
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.