BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 24588671)

  • 1. Evaluation of a synthetic single-crystal diamond detector for relative dosimetry measurements on a CyberKnife.
    Chalkley A; Heyes G
    Br J Radiol; 2014 Mar; 87(1035):20130768. PubMed ID: 24588671
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Clinical radiation therapy measurements with a new commercial synthetic single crystal diamond detector.
    Laub WU; Crilly R
    J Appl Clin Med Phys; 2014 Nov; 15(6):4890. PubMed ID: 25493512
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Small-field beam data acquisition, detector dependency, and film-based validation for a novel self-shielded stereotactic radiosurgery system.
    Pinnaduwage DS; Srivastava SP; Yan X; Jani SS; Jenkins C; Barani IJ; Sorensen S
    Med Phys; 2021 Oct; 48(10):6121-6136. PubMed ID: 34260069
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dosimetry of cone-defined stereotactic radiosurgery fields with a commercial synthetic diamond detector.
    Morales JE; Crowe SB; Hill R; Freeman N; Trapp JV
    Med Phys; 2014 Nov; 41(11):111702. PubMed ID: 25370616
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Determination of small field synthetic single-crystal diamond detector correction factors for CyberKnife, Leksell Gamma Knife Perfexion and linear accelerator.
    Veselsky T; Novotny J; Pastykova V; Koniarova I
    Phys Med; 2017 Dec; 44():66-71. PubMed ID: 29254593
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Multicenter evaluation of a synthetic single-crystal diamond detector for CyberKnife small field size output factors.
    Russo S; Masi L; Francescon P; Frassanito MC; Fumagalli ML; Marinelli M; Falco MD; Martinotti AS; Pimpinella M; Reggiori G; Verona Rinati G; Vigorito S; Mancosu P
    Phys Med; 2016 Apr; 32(4):575-81. PubMed ID: 27050172
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A study on the suitability of the PTW microDiamond detector for kilovoltage x-ray beam dosimetry.
    Damodar J; Odgers D; Pope D; Hill R
    Appl Radiat Isot; 2018 May; 135():104-109. PubMed ID: 29413822
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of a synthetic single-crystal diamond detector for relative dosimetry on the Leksell Gamma Knife Perfexion radiosurgery system.
    Mancosu P; Reggiori G; Stravato A; Gaudino A; Lobefalo F; Palumbo V; Navarria P; Ascolese A; Picozzi P; Marinelli M; Verona-Rinati G; Tomatis S; Scorsetti M
    Med Phys; 2015 Sep; 42(9):5035-41. PubMed ID: 26328954
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The output factor correction as function of the photon beam field size - direct measurement and calculation from the lateral dose response functions of gas-filled and solid detectors.
    Poppinga D; Delfs B; Meyners J; Harder D; Poppe B; Looe HK
    Z Med Phys; 2018 Aug; 28(3):224-235. PubMed ID: 28869164
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Characterization of a new commercial single crystal diamond detector for photon- and proton-beam dosimetry.
    Akino Y; Gautam A; Coutinho L; Würfel J; Das IJ
    J Radiat Res; 2015 Nov; 56(6):912-8. PubMed ID: 26268483
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An evaluation of solid state detectors for the relative dosimetry of kilovoltage X-ray beams.
    Daniel J; Yousif YAM; Zifodya J; Hill R
    Med Phys; 2022 Jun; 49(6):4082-4091. PubMed ID: 35179232
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Determination of the KQclinfclin,Qmsr fmsr correction factors for detectors used with an 800 MU/min CyberKnife(®) system equipped with fixed collimators and a study of detector response to small photon beams using a Monte Carlo method.
    Moignier C; Huet C; Makovicka L
    Med Phys; 2014 Jul; 41(7):071702. PubMed ID: 24989371
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Properties of a commercial PTW-60019 synthetic diamond detector for the dosimetry of small radiotherapy beams.
    Lárraga-Gutiérrez JM; Ballesteros-Zebadúa P; Rodríguez-Ponce M; García-Garduño OA; de la Cruz OO
    Phys Med Biol; 2015 Jan; 60(2):905-24. PubMed ID: 25564826
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Output factors of ionization chambers and solid state detectors for mobile intraoperative radiotherapy (IORT) accelerator electron beams.
    Güngör G; Aydın G; Mustafayev TZ; Özyar E
    J Appl Clin Med Phys; 2019 Feb; 20(2):13-23. PubMed ID: 30632271
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Investigation of a synthetic diamond detector response in kilovoltage photon beams.
    Kaveckyte V; Persson L; Malusek A; Benmakhlouf H; Alm Carlsson G; Carlsson Tedgren Å
    Med Phys; 2020 Mar; 47(3):1268-1279. PubMed ID: 31880809
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Small field dosimetry correction factors for circular and MLC shaped fields with the CyberKnife M6 System: evaluation of the PTW 60023 microSilicon detector.
    Francescon P; Kilby W; Noll JM; Satariano N; Orlandi C
    Phys Med Biol; 2020 Jan; 65(1):01NT01. PubMed ID: 31829983
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A Monte Carlo study on the PTW 60019 microDiamond detector.
    Hartmann GH; Zink K
    Med Phys; 2019 Nov; 46(11):5159-5172. PubMed ID: 31314919
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Characterization of a microDiamond detector in high-dose-per-pulse electron beams for intra operative radiation therapy.
    Di Venanzio C; Marinelli M; Tonnetti A; Verona-Rinati G; Falco MD; Pimpinella M; Ciccotelli A; De Stefano S; Felici G; Marangoni F
    Phys Med; 2015 Dec; 31(8):897-902. PubMed ID: 26160702
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Characterizing a PTW microDiamond detector in kilovoltage radiation beams.
    Khan AU; Culberson WS; DeWerd LA
    Med Phys; 2020 Sep; 47(9):4553-4562. PubMed ID: 32557666
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Monte Carlo simulated corrections for beam commissioning measurements with circular and MLC shaped fields on the CyberKnife M6 System: a study including diode, microchamber, point scintillator, and synthetic microdiamond detectors.
    Francescon P; Kilby W; Noll JM; Masi L; Satariano N; Russo S
    Phys Med Biol; 2017 Feb; 62(3):1076-1095. PubMed ID: 28033110
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.