These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
81 related articles for article (PubMed ID: 24588956)
1. Effects of humidity on foil and vial packaging to preserve glucose and lactate test strips for disaster readiness. Truong AT; Louie RF; Vy JH; Curtis CM; Ferguson WJ; Lam M; Sumner S; Kost GJ Disaster Med Public Health Prep; 2014 Feb; 8(1):51-7. PubMed ID: 24588956 [TBL] [Abstract][Full Text] [Related]
2. Effects of dynamic temperature and humidity stresses on point-of-care glucose testing for disaster care. Louie RF; Ferguson WJ; Sumner SL; Yu JN; Curtis CM; Kost GJ Disaster Med Public Health Prep; 2012 Oct; 6(3):232-40. PubMed ID: 23077265 [TBL] [Abstract][Full Text] [Related]
3. Effect of adverse storage conditions on performance of glucometer test strips. Bamberg R; Schulman K; MacKenzie M; Moore J; Olchesky S Clin Lab Sci; 2005; 18(4):203-9. PubMed ID: 16315736 [TBL] [Abstract][Full Text] [Related]
5. Maltose interference-free test strips for blood glucose testing at point-of-care: a laboratory performance evaluation. Ng WY; Tiong CC; Jacob E Diabetes Technol Ther; 2010 Nov; 12(11):889-93. PubMed ID: 20879959 [TBL] [Abstract][Full Text] [Related]
6. Effects of environmental conditions on point-of-care cardiac biomarker test performance during a simulated rescue: implications for emergency and disaster response. Louie RF; Ferguson WJ; Curtis CM; Vy JH; Tang CS; Kost GJ Am J Disaster Med; 2013; 8(3):205-12. PubMed ID: 24352994 [TBL] [Abstract][Full Text] [Related]
7. The Effects of Temperature and Relative Humidity on Point-of-Care Glucose Measurements in Hospital Practice in a Tropical Clinical Setting. Pratumvinit B; Charoenkoop N; Niwattisaiwong S; Kost GJ; Tientadakul P J Diabetes Sci Technol; 2016 Sep; 10(5):1094-100. PubMed ID: 26908568 [TBL] [Abstract][Full Text] [Related]
8. Thermal stress and point-of-care testing performance: suitability of glucose test strips and blood gas cartridges for disaster response. Louie RF; Sumner SL; Belcher S; Mathew R; Tran NK; Kost GJ Disaster Med Public Health Prep; 2009 Mar; 3(1):13-7. PubMed ID: 19293739 [TBL] [Abstract][Full Text] [Related]
9. Effects of Simulated Adverse Environmental Conditions Related to Actual Conditions at Health Promoting Hospitals on the Performance of Blood Glucose Testing by Glucose Meters. Apiratmateekul N; Duanginta W; Phetree M; Kongros K; Treebuphachatsakul W J Diabetes Sci Technol; 2023 Jan; 17(1):125-132. PubMed ID: 34515537 [TBL] [Abstract][Full Text] [Related]
10. Dynamic temperature and humidity environmental profiles: impact for future emergency and disaster preparedness and response. Ferguson WJ; Louie RF; Tang CS; Paw U KT; Kost GJ Prehosp Disaster Med; 2014 Feb; 29(1):4-12. PubMed ID: 24382031 [TBL] [Abstract][Full Text] [Related]
11. Effect of training on the performance of blood glucose monitoring using a reagent strip (Glucoprofil). Chantelau E; Starostina EG; Antsiferov MB Exp Clin Endocrinol; 1990 Nov; 96(2):192-8. PubMed ID: 2097164 [TBL] [Abstract][Full Text] [Related]
12. Reliability of glucose measurement by glucose test strips in tropical conditions. Ducorps M; Papoz L; Cuisinier-Raynal JC; Simon D Diabetes Res Clin Pract; 1992 Jul; 17(1):51-4. PubMed ID: 1511661 [TBL] [Abstract][Full Text] [Related]
13. Development of an enzymatic chromatography strip with nicotinamide adenine dinucleotide-tetrazolium coupling reactions for quantitative l-lactate analysis. Kan SC; Chang WF; Lan MC; Lin CC; Lai WS; Shieh CJ; Hsiung KP; Liu YC Anal Biochem; 2015 Feb; 471():61-6. PubMed ID: 25454507 [TBL] [Abstract][Full Text] [Related]
14. Impact of delayed arterial cord blood sampling for lactate assay: a prospective observational study. Dessolle L; Lebrec J; Daraï E Neonatology; 2009; 95(3):224-9. PubMed ID: 18953182 [TBL] [Abstract][Full Text] [Related]
15. Validation of a hand-held point of care device for lactate in adult and pediatric patients using traditional and locally-smoothed median and maximum absolute difference curves. Colon-Franco JM; Lo SF; Tarima SS; Gourlay D; Drendel AL; Brook Lerner E Clin Chim Acta; 2017 May; 468():145-149. PubMed ID: 28235428 [TBL] [Abstract][Full Text] [Related]
16. Blood glucose reagent strip tests in the operating room: influence of hematocrit, partial pressure of oxygen, and blood glucose level--a comparison of the BM-test 1-44, BM-Accutest, and Satellite G reagent strip systems. Cross MH; Brown DG J Clin Monit; 1996 Jan; 12(1):27-33. PubMed ID: 8732813 [TBL] [Abstract][Full Text] [Related]
17. Effect of ambient temperature on analytical performance of self-monitoring blood glucose systems. Nerhus K; Rustad P; Sandberg S Diabetes Technol Ther; 2011 Sep; 13(9):883-92. PubMed ID: 21714677 [TBL] [Abstract][Full Text] [Related]
18. Technical performance of lactate biosensors and a test-strip device during labour. Luttkus AK; Fotopoulou C; Sehouli J; Stupin J; Dudenhausen JW Z Geburtshilfe Neonatol; 2010 Apr; 214(2):62-7. PubMed ID: 20411473 [TBL] [Abstract][Full Text] [Related]
19. Calibration of glucose oxidase-based test strips for capillary blood measurement with oxygen saturated venous blood samples. Cheng WJ; Lin CW; Wu TG; Su CS; Hsieh MS Clin Chim Acta; 2013 Jan; 415():152-7. PubMed ID: 23089075 [TBL] [Abstract][Full Text] [Related]
20. Donald Rumsfeld and point-of-care testing (POCT): the problem of unknown unknowns-venous blood and glucose oxidase-based test strips. Reynolds TM; Pillay TS J Clin Pathol; 2016 Oct; 69(10):839-40. PubMed ID: 27432900 [No Abstract] [Full Text] [Related] [Next] [New Search]