167 related articles for article (PubMed ID: 24589822)
1. Optimising Mycobacterium tuberculosis detection in resource limited settings.
Alfred N; Lovette L; Aliyu G; Olusegun O; Meshak P; Jilang T; Iwakun M; Nnamdi E; Olubunmi O; Dakum P; Abimiku A
BMJ Open; 2014 Mar; 4(3):e004093. PubMed ID: 24589822
[TBL] [Abstract][Full Text] [Related]
2. Use of light-emitting diode fluorescence microscopy to detect acid-fast bacilli in sputum as proficient alternative tool in the diagnosis of pulmonary tuberculosis in countries with limited resource settings.
Coulibaly G; Georges Togo AC; Somboro AM; Kone M; Traore FG; Diallo F; Degoga B; Somboro A; Dramé HM; Sanogo M; Kodio O; Baya B; Tolofoudie M; Maiga A; Maiga M; Saliba-Shaw K; Diallo S; Doumbia S; Maiga II; Samaké F; Diarra B
Int J Mycobacteriol; 2023; 12(2):144-150. PubMed ID: 37338475
[TBL] [Abstract][Full Text] [Related]
3. Use of light-emitting diode fluorescence microscopy to detect acid-fast bacilli in sputum.
Marais BJ; Brittle W; Painczyk K; Hesseling AC; Beyers N; Wasserman E; van Soolingen D; Warren RM
Clin Infect Dis; 2008 Jul; 47(2):203-7. PubMed ID: 18532893
[TBL] [Abstract][Full Text] [Related]
4. LED fluorescence microscopy for the diagnosis of pulmonary tuberculosis: a multi-country cross-sectional evaluation.
Cuevas LE; Al-Sonboli N; Lawson L; Yassin MA; Arbide I; Al-Aghbari N; Sherchand JB; Al-Absi A; Emenyonu EN; Merid Y; Okobi MI; Onuoha JO; Aschalew M; Aseffa A; Harper G; de Cuevas RM; Theobald SJ; Nathanson CM; Joly J; Faragher B; Squire SB; Ramsay A
PLoS Med; 2011 Jul; 8(7):e1001057. PubMed ID: 21765809
[TBL] [Abstract][Full Text] [Related]
5. Comparison Of Ziehl-Neelsen Based Light Microscopy With Led Fluorescent Microscopy For Tuberculosis Diagnosis: An Insight From A Limited Resource-High Burden setting.
Noori MY; Ali F; Ali Z; Sharafat S
J Ayub Med Coll Abbottabad; 2017; 29(4):577-579. PubMed ID: 29330981
[TBL] [Abstract][Full Text] [Related]
6. [Performance of LED fluorescence microscopy for the detection of acid-fast bacilli from respiratory samples in peripheral laboratories in Argentina].
Imaz M; Allassia S; Aranibar M; Gunia A; Poggi S; Togneri A; Wolff L; Of Fluorescence GOI
Biomedica; 2017 Jun; 37(2):164-174. PubMed ID: 28527280
[TBL] [Abstract][Full Text] [Related]
7. Operational implementation of LED fluorescence microscopy in screening tuberculosis suspects in an urban HIV clinic in Uganda.
Albert H; Nakiyingi L; Sempa J; Mbabazi O; Mukkada S; Nyesiga B; Perkins MD; Manabe YC
PLoS One; 2013; 8(9):e72556. PubMed ID: 24039780
[TBL] [Abstract][Full Text] [Related]
8. The manual MGIT system for the detection of M. tuberculosis in respiratory specimens: an experience in the University Malaya Medical Centre.
Fadzilah MN; Ng KP; Ngeow YF
Malays J Pathol; 2009 Dec; 31(2):93-7. PubMed ID: 20514851
[TBL] [Abstract][Full Text] [Related]
9. Diagnostic performance of smear microscopy and incremental yield of Xpert in detection of pulmonary tuberculosis in Rwanda.
Ngabonziza JC; Ssengooba W; Mutua F; Torrea G; Dushime A; Gasana M; Andre E; Uwamungu S; Nyaruhirira AU; Mwaengo D; Muvunyi CM
BMC Infect Dis; 2016 Nov; 16(1):660. PubMed ID: 27825314
[TBL] [Abstract][Full Text] [Related]
10. Agreement between Direct Fluorescent Microscopy and Ziehl-Neelsen Concentration Techniques in Detection of Pulmonary Tuberculosis in Northwest Ethiopia.
Workineh M; Maru M; Seman I; Bezu Z; Negash M; Melku M; Gize A; Shibabaw A
Ethiop J Health Sci; 2017 Sep; 27(5):459-464. PubMed ID: 29217950
[TBL] [Abstract][Full Text] [Related]
11. Evaluation of 'TBDetect' sputum microscopy kit for improved detection of Mycobacterium tuberculosis: a multi-centric validation study.
Anthwal D; Gupta RK; Gomathi NS; Tripathy SP; Das D; Pati S; Panwalkar N; Desikan P; Bala K; Singh UB; Bhalla M; Singhal R; Verma AK; Khayyam KU; Myneedu VP; Sarin R; Sharma S; Bansal AK; Gupta UD; Patil SA; Goyal A; Gupta A; Singh M; Gupta NK; Haldar S; Tyagi JS
Clin Microbiol Infect; 2021 Jun; 27(6):911.e1-911.e7. PubMed ID: 32835794
[TBL] [Abstract][Full Text] [Related]
12. A comparative study of fluorescent microscopy with Ziehl-Neelsen staining and culture for the diagnosis of pulmonary tuberculosis.
Laifangbam S; Singh HL; Singh NB; Devi KM; Singh NT
Kathmandu Univ Med J (KUMJ); 2009; 7(27):226-30. PubMed ID: 20071867
[TBL] [Abstract][Full Text] [Related]
13. A comparison of direct microscopy, the concentration method and the Mycobacteria Growth Indicator Tube for the examination of sputum for acid-fast bacilli.
Apers L; Mutsvangwa J; Magwenzi J; Chigara N; Butterworth A; Mason P; Van der Stuyft P
Int J Tuberc Lung Dis; 2003 Apr; 7(4):376-81. PubMed ID: 12729344
[TBL] [Abstract][Full Text] [Related]
14. Rapid laboratory diagnosis of pulmonary tuberculosis.
Bhirud P; Joshi A; Hirani N; Chowdhary A
Int J Mycobacteriol; 2017; 6(3):296-301. PubMed ID: 28776530
[TBL] [Abstract][Full Text] [Related]
15. Light-emitting diode with various sputum smear preparation techniques to diagnose tuberculosis.
Habtamu M; van den Boogaard J; Ndaro A; Buretta R; Irongo CF; Lega DA; Nyombi BM; Kibiki GS
Int J Tuberc Lung Dis; 2012; 16(3):402-7. PubMed ID: 22640455
[TBL] [Abstract][Full Text] [Related]
16. Light-emitting diode fluorescent microscopy and Xpert MTB/RIF® assay for diagnosis of pulmonary tuberculosis among patients attending Ambo hospital, west-central Ethiopia.
Gelalcha AG; Kebede A; Mamo H
BMC Infect Dis; 2017 Sep; 17(1):613. PubMed ID: 28893193
[TBL] [Abstract][Full Text] [Related]
17. Usefulness of light emitting diode (LED) fluorescent microscopy as a tool for rapid and effective method for the diagnosis of pulmonary tuberculosis.
Khatun Z; Kamal M; Roy CK; Sultana T; Rahman MQ; Azad MB; Ahmed AN
Bangladesh Med Res Counc Bull; 2011 Apr; 37(1):7-10. PubMed ID: 21710809
[TBL] [Abstract][Full Text] [Related]
18. Comparison of LED and conventional fluorescence microscopy for detection of acid-fast bacilli in an area with high tuberculosis incidence.
Marzouk M; Ferjani A; Dhaou M; Ali MH; Hannachi N; Boukadida J
Diagn Microbiol Infect Dis; 2013 Jul; 76(3):306-8. PubMed ID: 23632250
[TBL] [Abstract][Full Text] [Related]
19. Performance of three LED-based fluorescence microscopy systems for detection of tuberculosis in Uganda.
Albert H; Manabe Y; Lukyamuzi G; Ademun P; Mukkada S; Nyesiga B; Joloba M; Paramasivan CN; Perkins MD
PLoS One; 2010 Dec; 5(12):e15206. PubMed ID: 21203398
[TBL] [Abstract][Full Text] [Related]
20. The value of fluorescence microscopy of auramine stained sputum smears for the diagnosis of pulmonary tuberculosis.
Singh NP; Parija SC
Southeast Asian J Trop Med Public Health; 1998 Dec; 29(4):860-3. PubMed ID: 10772577
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]