BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

182 related articles for article (PubMed ID: 24593709)

  • 21. Real-time 3D internal marker tracking during arc radiotherapy by the use of combined MV-kV imaging.
    Liu W; Wiersma RD; Mao W; Luxton G; Xing L
    Phys Med Biol; 2008 Dec; 53(24):7197-213. PubMed ID: 19043177
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Motion as perturbation. II. Development of the method for dosimetric analysis of motion effects with fixed-gantry IMRT.
    Nelms BE; Opp D; Zhang G; Moros E; Feygelman V
    Med Phys; 2014 Jun; 41(6):061704. PubMed ID: 24877799
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Quality assurance of a gimbaled head swing verification using feature point tracking.
    Miura H; Ozawa S; Enosaki T; Kawakubo A; Hosono F; Yamada K; Nagata Y
    J Appl Clin Med Phys; 2017 Jan; 18(1):49-52. PubMed ID: 28291928
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Dosimetric characterization of a multileaf collimator for a new four-dimensional image-guided radiotherapy system with a gimbaled x-ray head, MHI-TM2000.
    Nakamura M; Sawada A; Ishihara Y; Takayama K; Mizowaki T; Kaneko S; Yamashita M; Tanabe H; Kokubo M; Hiraoka M
    Med Phys; 2010 Sep; 37(9):4684-91. PubMed ID: 20964187
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Initial application of a geometric QA tool for integrated MV and kV imaging systems on three image guided radiotherapy systems.
    Mao W; Speiser M; Medin P; Papiez L; Solberg T; Xing L
    Med Phys; 2011 May; 38(5):2335-41. PubMed ID: 21776767
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Targeting accuracy of an image guided gating system for stereotactic body radiotherapy.
    Tenn SE; Solberg TD; Medin PM
    Phys Med Biol; 2005 Dec; 50(23):5443-62. PubMed ID: 16306644
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Real-time tumor tracking: automatic compensation of target motion using the Siemens 160 MLC.
    Tacke MB; Nill S; Krauss A; Oelfke U
    Med Phys; 2010 Feb; 37(2):753-61. PubMed ID: 20229885
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Development and commissioning of a full-size prototype fixed-beam radiotherapy system with horizontal patient rotation.
    Liu PZY; O'Brien R; Heng SM; Newall M; Downes S; Shieh CC; Corde S; Jackson M; Keall P
    Med Phys; 2019 Mar; 46(3):1331-1340. PubMed ID: 30582751
    [TBL] [Abstract][Full Text] [Related]  

  • 29. An oscillating sweeping gap test for VMAT quality assurance.
    Bhagwat MS; Han Z; Ng SK; Zygmanski P
    Phys Med Biol; 2010 Sep; 55(17):5029-44. PubMed ID: 20702923
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Quality assurance devices for dynamic conformal radiotherapy.
    Wong VY
    J Appl Clin Med Phys; 2004; 5(1):8-15. PubMed ID: 15753929
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Dosimetric and mechanical characteristics of a commercial dynamic microMLC used in SRS.
    Galal MM; Keogh S; Khalil S
    Med Phys; 2011 Jul; 38(7):4225-31. PubMed ID: 21859024
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Accuracy of cranial coplanar beam therapy using an oblique, stereoscopic x-ray image guidance system.
    Vinci JP; Hogstrom KR; Neck DW
    Med Phys; 2008 Aug; 35(8):3809-19. PubMed ID: 18777940
    [TBL] [Abstract][Full Text] [Related]  

  • 33. RapidArc patient specific mechanical delivery accuracy under extreme mechanical limits using linac log files.
    Wijesooriya K; Aliotta E; Benedict S; Read P; Rich T; Larner J
    Med Phys; 2012 Apr; 39(4):1846-53. PubMed ID: 22482606
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Technical aspects of real time positron emission tracking for gated radiotherapy.
    Chamberland M; McEwen MR; Xu T
    Med Phys; 2016 Feb; 43(2):783-95. PubMed ID: 26843241
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Development of a four-dimensional image-guided radiotherapy system with a gimbaled X-ray head.
    Kamino Y; Takayama K; Kokubo M; Narita Y; Hirai E; Kawawda N; Mizowaki T; Nagata Y; Nishidai T; Hiraoka M
    Int J Radiat Oncol Biol Phys; 2006 Sep; 66(1):271-8. PubMed ID: 16820270
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Leaf position error during conformal dynamic arc and intensity modulated arc treatments.
    Ramsey CR; Spencer KM; Alhakeem R; Oliver AL
    Med Phys; 2001 Jan; 28(1):67-72. PubMed ID: 11213924
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Dosimetric and radiobiological impact of dose fractionation on respiratory motion induced IMRT delivery errors: a volumetric dose measurement study.
    Duan J; Shen S; Fiveash JB; Popple RA; Brezovich IA
    Med Phys; 2006 May; 33(5):1380-7. PubMed ID: 16752574
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Implementation of a new method for dynamic multileaf collimator tracking of prostate motion in arc radiotherapy using a single kV imager.
    Poulsen PR; Cho B; Sawant A; Keall PJ
    Int J Radiat Oncol Biol Phys; 2010 Mar; 76(3):914-23. PubMed ID: 19910138
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Experimental validation of heterogeneity-corrected dose-volume prescription on respiratory-averaged CT images in stereotactic body radiotherapy for moving tumors.
    Nakamura M; Miyabe Y; Matsuo Y; Kamomae T; Nakata M; Yano S; Sawada A; Mizowaki T; Hiraoka M
    Med Dosim; 2012; 37(1):20-5. PubMed ID: 21497502
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Testing of the stability of intensity modulated beams generated with dynamic multileaf collimation, applied to the MM50 racetrack microtron.
    Dirkx ML; Heijmen BJ
    Med Phys; 2000 Dec; 27(12):2701-7. PubMed ID: 11190953
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.