  • 1. Worsening late-acquired incomplete stent apposition after sirolimus-eluting stent implantation for a chronic total occlusion lesion.
    Nakazato K; Misaka T; Sakamoto N; Kunii H; Saitoh S; Takeishi Y
    Cardiovasc Interv Ther; 2015 Jan; 30(1):85-91. PubMed ID: 24595874
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Very late stent thrombosis after sirolimus-eluting stent implantation: evaluation by intravascular ultrasound and optical coherence tomography.
    Mabuchi T; Fujino S; Yamaguchi M; Noji Y; Ichise T; Aoyama T
    Cardiovasc Interv Ther; 2013 Oct; 28(4):388-93. PubMed ID: 23558923
    [TBL] [Abstract][Full Text] [Related]  

  • 3. First-in-human evaluation of a bioabsorbable polymer-coated sirolimus-eluting stent: imaging and clinical results of the DESSOLVE I Trial (DES with sirolimus and a bioabsorbable polymer for the treatment of patients with de novo lesion in the native coronary arteries).
    Ormiston J; Webster M; Stewart J; Vrolix M; Whitbourn R; Donohoe D; Knape C; Lansky A; Attizzani GF; Fitzgerald P; Kandzari DE; Wijns W
    JACC Cardiovasc Interv; 2013 Oct; 6(10):1026-34. PubMed ID: 24055443
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Very late thrombosis after subintimal sirolimus-eluting stent implantation during percutaneous coronary intervention for chronic total occlusion.
    Miyazaki S; Hiasa Y; Kishi K
    J Invasive Cardiol; 2010 Aug; 22(8):E162-5. PubMed ID: 20679685
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The fate of incomplete stent apposition with drug-eluting stents: an optical coherence tomography-based natural history study.
    Ozaki Y; Okumura M; Ismail TF; Naruse H; Hattori K; Kan S; Ishikawa M; Kawai T; Takagi Y; Ishii J; Prati F; Serruys PW
    Eur Heart J; 2010 Jun; 31(12):1470-6. PubMed ID: 20363765
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Impact of late incomplete stent apposition after sirolimus-eluting stent implantation on 4-year clinical events: intravascular ultrasound analysis from the multicentre, randomised, RAVEL, E-SIRIUS and SIRIUS trials.
    Hoffmann R; Morice MC; Moses JW; Fitzgerald PJ; Mauri L; Breithardt G; Schofer J; Serruys PW; Stoll HP; Leon MB
    Heart; 2008 Mar; 94(3):322-8. PubMed ID: 17761505
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Very late thrombosis of sirolimus-eluting stent due to late malapposition: serial observations with optical coherence tomography.
    Sawada T; Shite J; Shinke T; Tanino Y; Ogasawara D; Kawamori H; Kato H; Miyoshi N; Yoshino N; Hirata K
    J Cardiol; 2008 Dec; 52(3):290-5. PubMed ID: 19027609
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Efficacy of Endeavor zotarolimus-eluting stent implantation for the treatment of very late stent thrombosis with late-acquired incomplete stent apposition after sirolimus-eluting stent implantation.
    Kakefuda Y; Sato A; Watabe H; Aihara H; Nishina H; Noguchi Y; Hoshi T; Aonuma K
    Heart Vessels; 2016 Jul; 31(7):1196-9. PubMed ID: 26219730
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Acute coronary syndrome is an independent risk factor for late incomplete stent apposition after sirolimus-eluting stent implantation.
    Zhang RY; DU R; Zhu ZB; Zhang Q; Hu J; Lü AK; Zhang JS; Shen WF
    Chin Med J (Engl); 2008 Dec; 121(24):2504-8. PubMed ID: 19187586
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Impact of preinterventional plaque composition and eccentricity on late-acquired incomplete stent apposition after sirolimus-eluting stent implantation: an intravascular ultrasound radiofrequency analysis.
    Sato T; Kameyama T; Noto T; Nozawa T; Inoue H
    Coron Artery Dis; 2012 Nov; 23(7):432-7. PubMed ID: 22936019
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Correlation of intravascular ultrasound findings with histopathological analysis of thrombus aspirates in patients with very late drug-eluting stent thrombosis.
    Cook S; Ladich E; Nakazawa G; Eshtehardi P; Neidhart M; Vogel R; Togni M; Wenaweser P; Billinger M; Seiler C; Gay S; Meier B; Pichler WJ; Jüni P; Virmani R; Windecker S
    Circulation; 2009 Aug; 120(5):391-9. PubMed ID: 19620501
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Late-acquired incomplete stent apposition after everolimus-eluting stent versus sirolimus-eluting stent implantation in patients with non-ST-segment elevation myocardial infarction and ST-segment elevation myocardial infarction.
    Hur SH; Lee BR; Kim SW; Hong YJ; Bae JH; Choi D; Kang HJ; Choi SY; Lee SG; Kim DI; Park JS; Rha SW
    EuroIntervention; 2016 Oct; 12(8):e979-e986. PubMed ID: 26403637
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Mechanisms, pathophysiology, and clinical aspects of incomplete stent apposition.
    Attizzani GF; Capodanno D; Ohno Y; Tamburino C
    J Am Coll Cardiol; 2014 Apr; 63(14):1355-67. PubMed ID: 24530675
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Optical coherence tomography findings in lesions after sirolimus-eluting stent implantation with peri-stent contrast staining.
    Tada T; Kadota K; Hosogi S; Kubo S; Ozaki M; Yoshino M; Miyake K; Eguchi H; Ohashi N; Hayakawa Y; Saito N; Otsuru S; Hasegawa D; Shigemoto Y; Habara S; Imai M; Tanaka H; Fuku Y; Oka N; Kato H; Yamamoto H; Fujii S; Goto T; Mitsudo K
    Circ Cardiovasc Interv; 2012 Oct; 5(5):649-56. PubMed ID: 23011265
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of long-term follow-up with neointimal coverage and stent apposition after sirolimus-eluting stent implantation by optical coherence tomography.
    Li S; Gai L; Yang T; Zhang L; Xu X; Bai Q; Xu H; Wang Y
    Catheter Cardiovasc Interv; 2013 Apr; 81(5):768-75. PubMed ID: 22639418
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Initial findings of impact of strut width on stent coverage and apposition of sirolimus-eluting stents assessed by optical coherence tomography.
    Nakatani S; Nishino M; Taniike M; Makino N; Kato H; Egami Y; Shutta R; Tanouchi J; Yamada Y
    Catheter Cardiovasc Interv; 2013 Apr; 81(5):776-81. PubMed ID: 22517601
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Late incomplete apposition after drug-eluting stent implantation: incidence and potential for adverse clinical outcomes.
    Siqueira DA; Abizaid AA; Costa Jde R; Feres F; Mattos LA; Staico R; Abizaid AA; Tanajura LF; Chaves A; Centemero M; Sousa AG; Sousa JE
    Eur Heart J; 2007 Jun; 28(11):1304-9. PubMed ID: 17478457
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Successful treatment of very late drug-eluting stent thrombosis using bare-metal stent evaluated using intravascular ultrasound and optical frequency domain imaging.
    Matsumoto K; Ehara S; Hasegawa T; Sakaguchi M; Yoshikawa J; Shimada K
    Cardiovasc Interv Ther; 2017 Apr; 32(2):159-164. PubMed ID: 26983634
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Frequency and characteristics of incomplete stent apposition during and after sirolimus-eluting stent implantation].
    Takeuchi H; Morino Y; Fujibayashi D; Hashida T; Kawamura Y; Tsumuraya N; Okamoto N; Nagaoka M; Ikari Y; Tanabe T
    J Cardiol; 2007 Aug; 50(2):111-8. PubMed ID: 17802694
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Outcomes of everolimus-eluting stent incomplete stent apposition: a serial optical coherence tomography analysis.
    Shimamura K; Kubo T; Akasaka T; Kozuma K; Kimura K; Kawamura M; Sumiyoshi T; Ino Y; Yoshiyama M; Sonoda S; Igarashi K; Miyazawa A; Uzui H; Sakanoue Y; Shinke T; Morino Y; Tanabe K; Kadota K; Kimura T
    Eur Heart J Cardiovasc Imaging; 2015 Jan; 16(1):23-8. PubMed ID: 25342855