158 related articles for article (PubMed ID: 24602034)
1. Separation of centrifuged whole blood and pooled buffy coats using the new CompoMat G5: 3 years experience.
Bontekoe IJ; van der Meer PF; Mast G; de Korte D
Vox Sang; 2014 Aug; 107(2):140-7. PubMed ID: 24602034
[TBL] [Abstract][Full Text] [Related]
2. [Analysis of the quality of hemoderivatives obtained using a buffy-coat extraction system with a top-and-bottom technique (Optipress II)].
Hurtado C; Bonanad S; Soler MA; Mirabet V; Blasco I; Planelles MD; de Miguel A
Sangre (Barc); 1999 Oct; 44(5):319-26. PubMed ID: 10618907
[TBL] [Abstract][Full Text] [Related]
3. Improved BC method of Compomat G4 for expression of BCs twice from whole blood in top and top bags.
Deng XY; Wu XM; Zhao Y; Luo H; Jia HY; Wang ZY; He B; Wang CX
Int J Hematol; 2011 May; 93(5):660-663. PubMed ID: 21516305
[TBL] [Abstract][Full Text] [Related]
4. Automated separation of whole blood in top and bottom bags into components using the Compomat G4.
van der Meer P; Pietersz R; Hinloopen B; Dekker W; Reesink H
Vox Sang; 1999; 76(2):90-9. PubMed ID: 10085525
[TBL] [Abstract][Full Text] [Related]
5. Quality analysis of blood components obtained by automated buffy-coat layer removal with a top & bottom system (Optipress (R)II).
Hurtado C; Bonanad S; Soler Mf; Mirabet V; Blasco I; Planelles Mf; De Miguel A
Haematologica; 2000 Apr; 85(4):390-5. PubMed ID: 10756365
[TBL] [Abstract][Full Text] [Related]
6. [Preparation of pooled granulocytes concentrates from whole blood buffy coats (PGC) as an alternative to apheresis].
Mastronardi R; Cleophax S; Begué S; Hurtado-Nedelec M; Gross S; Bocquet T; Djoudi R
Transfus Clin Biol; 2019 Sep; 26(3):164-170. PubMed ID: 31400933
[TBL] [Abstract][Full Text] [Related]
7. Preparation of leukodepleted platelet concentrates from pooled buffy coats: prestorage filtration with Autostop BC.
Pietersz RN; van der Meer PF; Steneker I; Hinloopen B; Dekker WJ; van Zanten AP; Reesink HW
Vox Sang; 1999; 76(4):231-6. PubMed ID: 10394143
[TBL] [Abstract][Full Text] [Related]
8. Evaluation of the quality of blood components prepared using the Reveos automated blood processing system.
Johnson L; Winter KM; Kwok M; Reid S; Marks DC
Vox Sang; 2013 Oct; 105(3):225-35. PubMed ID: 23713603
[TBL] [Abstract][Full Text] [Related]
9. Automated blood component collection with the MCS 3p cell separator: evaluation of three protocols for buffy coat-poor and white cell-reduced packed red cells and plasma.
Zeiler TA; Kretschmer V
Transfusion; 1997 Aug; 37(8):791-7. PubMed ID: 9280322
[TBL] [Abstract][Full Text] [Related]
10. Quality control of buffy coat removed red cell concentrates--a Croatian experience.
Vuk T; Očić T; Patko MS; Jukić I
Transfus Med; 2014 Dec; 24(6):385-91. PubMed ID: 25469715
[TBL] [Abstract][Full Text] [Related]
11. Quality and standardization in blood component preparation with an automated blood processing technique.
van Rhenen DJ; Vermeij J; de Voogt J; Bernes JC; Payrat JM
Transfus Med; 1998 Dec; 8(4):319-24. PubMed ID: 9881426
[TBL] [Abstract][Full Text] [Related]
12. [Blood fractionation based on the extraction of the buffy-coat layer. Analysis of our results].
Algora M; Torres P; Rodríguez MA; de la Calle C; Biurrún M; Nieto S; Ruiz M; Alonso MV
Sangre (Barc); 1995 Apr; 40(2):91-6. PubMed ID: 7784953
[TBL] [Abstract][Full Text] [Related]
13. [Quality of buffy-coat-derived platelet concentrates prepared using automated system terumo automated centrifuge and separator integration (TACSI)].
Zebrowska A; Lipska A; Rogowska A; Bujno M; Nedzi M; Radziwon P
Pol Merkur Lekarski; 2011 Mar; 30(177):191-4. PubMed ID: 21544996
[TBL] [Abstract][Full Text] [Related]
14. Differences in residual white blood cell subset counts in buffy coat-depleted red cell concentrates prepared with bottom and top or quadruple-bag systems.
de Wildt-Eggen J; Schrijver JG; Kuiper-Kramer PA; Bins M; van Prooijen HC
Vox Sang; 1999; 77(2):97-102. PubMed ID: 10516554
[TBL] [Abstract][Full Text] [Related]
15. Improvement of the separation of blood by modification of separators Optipress and Biotrans Separator.
Kretschmer V; Tesche U; Richter P
Beitr Infusionsther; 1992; 30():112-21. PubMed ID: 1284685
[TBL] [Abstract][Full Text] [Related]
16. Leucoreduced platelet concentrates in additive solution: an evaluation of filters and storage containers.
van der Meer P; Pietersz R; Reesink H
Vox Sang; 2001; 81(2):102-7. PubMed ID: 11555469
[TBL] [Abstract][Full Text] [Related]
17. Blood component fractionation: manual versus automatic procedures.
Pasqualetti D; Ghirardini A; Cristina Arista M; Vaglio S; Fakeri A; Waldman AA; Girelli G
Transfus Apher Sci; 2004 Feb; 30(1):23-8. PubMed ID: 14746818
[TBL] [Abstract][Full Text] [Related]
18. Quality assessment of buffy-coat-derived leucodepleted platelet concentrates in PAS-plasma, prepared by the OrbiSac or TACSI automated system.
Plaza EM; Céspedes P; Fernández H; Sánchez-Guiu MI; Egea JM; Vicente V; Lozano ML; Rivera J
Vox Sang; 2014 Jan; 106(1):38-44. PubMed ID: 23888911
[TBL] [Abstract][Full Text] [Related]
19. Automated processing of whole blood units: operational value and in vitro quality of final blood components.
Jurado M; Algora M; Garcia-Sanchez F; Vico S; Rodriguez E; Perez S; Barbolla L
Blood Transfus; 2012 Jan; 10(1):63-71. PubMed ID: 22044958
[TBL] [Abstract][Full Text] [Related]
20. Implementation of buffy coat platelet component production: comparison to platelet-rich plasma platelet production.
Levin E; Culibrk B; Gyöngyössy-Issa MI; Weiss S; Scammell K; LeFresne W; Jenkins C; Devine DV
Transfusion; 2008 Nov; 48(11):2331-7. PubMed ID: 18631169
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]