175 related articles for article (PubMed ID: 24604470)
1. Twelve million resolving power on 4.7 T Fourier transform ion cyclotron resonance instrument with dynamically harmonized cell--observation of fine structure in peptide mass spectra.
Popov IA; Nagornov K; Vladimirov GN; Kostyukevich YI; Nikolaev EN
J Am Soc Mass Spectrom; 2014 May; 25(5):790-9. PubMed ID: 24604470
[TBL] [Abstract][Full Text] [Related]
2. Fine Structure in Isotopic Peak Distributions Measured Using Fourier Transform Ion Cyclotron Resonance Mass Spectrometry: A Comparison between an Infinity ICR Cell and a Dynamically Harmonized ICR Cell.
Xu J; Li M; Marzullo B; Wootton CA; Barrow MP; O'Connor PB
J Am Soc Mass Spectrom; 2022 Aug; 33(8):1499-1509. PubMed ID: 35763614
[TBL] [Abstract][Full Text] [Related]
3. Fine structure in isotopic peak distributions measured using a dynamically harmonized Fourier transform ion cyclotron resonance cell at 7 T.
Nikolaev EN; Jertz R; Grigoryev A; Baykut G
Anal Chem; 2012 Mar; 84(5):2275-83. PubMed ID: 22304699
[TBL] [Abstract][Full Text] [Related]
4. Electron-induced dissociation of peptides in a triple quadrupole mass spectrometer retrofitted with an electromagnetostatic cell.
Voinov VG; Bennett SE; Barofsky DF
J Am Soc Mass Spectrom; 2015 May; 26(5):752-61. PubMed ID: 25652934
[TBL] [Abstract][Full Text] [Related]
5. Realistic modeling of ion cloud motion in a Fourier transform ion cyclotron resonance cell by use of a particle-in-cell approach.
Nikolaev EN; Heeren RM; Popov AM; Pozdneev AV; Chingin KS
Rapid Commun Mass Spectrom; 2007; 21(22):3527-46. PubMed ID: 17944004
[TBL] [Abstract][Full Text] [Related]
6. Absorption-mode spectra on the dynamically harmonized Fourier transform ion cyclotron resonance cell.
Qi Y; Witt M; Jertz R; Baykut G; Barrow MP; Nikolaev EN; O'Connor PB
Rapid Commun Mass Spectrom; 2012 Sep; 26(17):2021-6. PubMed ID: 22847701
[TBL] [Abstract][Full Text] [Related]
7. Elimination of frequency drift from Fourier transform ion cyclotron resonance mass spectra by digital quadrature heterodyning: ultrahigh mass resolving power for laser-desorbed molecules.
Guan S; Wahl MC; Marshall AG
Anal Chem; 1993 Dec; 65(24):3647-53. PubMed ID: 8311249
[TBL] [Abstract][Full Text] [Related]
8. Potential of dynamically harmonized Fourier transform ion cyclotron resonance cell for high-throughput metabolomics fingerprinting: control of data quality.
Habchi B; Alves S; Jouan-Rimbaud Bouveresse D; Appenzeller B; Paris A; Rutledge DN; Rathahao-Paris E
Anal Bioanal Chem; 2018 Jan; 410(2):483-490. PubMed ID: 29167936
[TBL] [Abstract][Full Text] [Related]
9. Fourier transform ion cyclotron resonance mass resolution and dynamic range limits calculated by computer modeling of ion cloud motion.
Vladimirov G; Hendrickson CL; Blakney GT; Marshall AG; Heeren RM; Nikolaev EN
J Am Soc Mass Spectrom; 2012 Feb; 23(2):375-84. PubMed ID: 22033889
[TBL] [Abstract][Full Text] [Related]
10. FT-ICR Mass Spectrometry Imaging at Extreme Mass Resolving Power Using a Dynamically Harmonized ICR Cell with 1ω or 2ω Detection.
Tiquet M; La Rocca R; Kirnbauer S; Zoratto S; Van Kruining D; Quinton L; Eppe G; Martinez-Martinez P; Marchetti-Deschmann M; De Pauw E; Far J
Anal Chem; 2022 Jul; 94(26):9316-9326. PubMed ID: 35604839
[TBL] [Abstract][Full Text] [Related]
11. Fourier transform ion cyclotron resonance mass spectrometry in a 20 T resistive magnet.
Hendrickson CL; Drader JJ; Laude DA; Guan S; Marshall AG
Rapid Commun Mass Spectrom; 1996; 10(14):1829-32. PubMed ID: 8953785
[TBL] [Abstract][Full Text] [Related]
12. High-resolution Fourier transform ion cyclotron resonance mass spectrometry with increased throughput for biomolecular analysis.
Nagornov KO; Gorshkov MV; Kozhinov AN; Tsybin YO
Anal Chem; 2014 Sep; 86(18):9020-8. PubMed ID: 25140615
[TBL] [Abstract][Full Text] [Related]
13. Towards analytically useful two-dimensional Fourier transform ion cyclotron resonance mass spectrometry.
van Agthoven MA; Delsuc MA; Bodenhausen G; Rolando C
Anal Bioanal Chem; 2013 Jan; 405(1):51-61. PubMed ID: 23076397
[TBL] [Abstract][Full Text] [Related]
14. Trapped-ion cell with improved DC potential harmonicity for FT-ICR MS.
Tolmachev AV; Robinson EW; Wu S; Kang H; Lourette NM; Pasa-Tolić L; Smith RD
J Am Soc Mass Spectrom; 2008 Apr; 19(4):586-97. PubMed ID: 18296061
[TBL] [Abstract][Full Text] [Related]
15. Counting individual sulfur atoms in a protein by ultrahigh-resolution Fourier transform ion cyclotron resonance mass spectrometry: experimental resolution of isotopic fine structure in proteins.
Shi SD; Hendrickson CL; Marshall AG
Proc Natl Acad Sci U S A; 1998 Sep; 95(20):11532-7. PubMed ID: 9751700
[TBL] [Abstract][Full Text] [Related]
16. Generalization of an Open Dynamically Harmonized Cell for Ultrahigh FT ICR Resolution.
Lioznov A; Nikolaev E
J Am Soc Mass Spectrom; 2022 Nov; 33(11):2032-2037. PubMed ID: 36251283
[TBL] [Abstract][Full Text] [Related]
17. Carbohydrate analysis by desorption electrospray ionization fourier transform ion cyclotron resonance mass spectrometry.
Bereman MS; Williams TI; Muddiman DC
Anal Chem; 2007 Nov; 79(22):8812-5. PubMed ID: 17918969
[TBL] [Abstract][Full Text] [Related]
18. Tailored ion radius distribution for increased dynamic range in FT-ICR mass analysis of complex mixtures.
Kaiser NK; McKenna AM; Savory JJ; Hendrickson CL; Marshall AG
Anal Chem; 2013 Jan; 85(1):265-72. PubMed ID: 23194162
[TBL] [Abstract][Full Text] [Related]
19. MS/MS with high detection efficiency and mass resolving power for product ions in Fourier transform ion cyclotron resonance mass spectrometry.
Guan S; Marshall AG; Wahl MC
Anal Chem; 1994 Apr; 66(8):1363-7. PubMed ID: 7516123
[TBL] [Abstract][Full Text] [Related]
20. Atmospheric pressure ionization permanent magnet fourier transform ion cyclotron resonance mass spectrometry.
Vilkov AN; Gamage CM; Misharin AS; Doroshenko VM; Tolmachev DA; Tarasova IA; Kharybin ON; Novoselov KP; Gorshkov MV
J Am Soc Mass Spectrom; 2007 Aug; 18(8):1552-8. PubMed ID: 17587594
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]