These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 24610893)

  • 21. Electrochemical and biocompatibility examinations of high-pressure torsion processed titanium and Ti-13Nb-13Zr alloy.
    Dimić I; Cvijović-Alagić I; Hohenwarter A; Pippan R; Kojić V; Bajat J; Rakin M
    J Biomed Mater Res B Appl Biomater; 2018 Apr; 106(3):1097-1107. PubMed ID: 28503902
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Corrosion behavior of titanium in the presence of calcium phosphate and serum proteins.
    Cheng X; Roscoe SG
    Biomaterials; 2005 Dec; 26(35):7350-6. PubMed ID: 16023203
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Cathodic voltage-controlled electrical stimulation of titanium for prevention of methicillin-resistant Staphylococcus aureus and Acinetobacter baumannii biofilm infections.
    Canty M; Luke-Marshall N; Campagnari A; Ehrensberger M
    Acta Biomater; 2017 Jan; 48():451-460. PubMed ID: 27890730
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Functionalized graphene oxide coating on Ti6Al4V alloy for improved biocompatibility and corrosion resistance.
    Asgar H; Deen KM; Rahman ZU; Shah UH; Raza MA; Haider W
    Mater Sci Eng C Mater Biol Appl; 2019 Jan; 94():920-928. PubMed ID: 30423780
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Electrochemical characterization of cast Ti-Hf binary alloys.
    Cai Z; Koike M; Sato H; Brezner M; Guo Q; Komatsu M; Okuno O; Okabe T
    Acta Biomater; 2005 May; 1(3):353-6. PubMed ID: 16701813
    [TBL] [Abstract][Full Text] [Related]  

  • 26. A time-based potential step analysis of electrochemical impedance incorporating a constant phase element: a study of commercially pure titanium in phosphate buffered saline.
    Ehrensberger MT; Gilbert JL
    J Biomed Mater Res A; 2010 May; 93(2):576-84. PubMed ID: 19591235
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Nitric acid passivation of Ti6Al4V reduces thickness of surface oxide layer and increases trace element release.
    Callen BW; Lowenberg BF; Lugowski S; Sodhi RN; Davies JE
    J Biomed Mater Res; 1995 Mar; 29(3):279-90. PubMed ID: 7615579
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Corrosion behavior of titanium boride composite coating fabricated on commercially pure titanium in Ringer's solution for bioimplant applications.
    Sivakumar B; Singh R; Pathak LC
    Mater Sci Eng C Mater Biol Appl; 2015 Mar; 48():243-55. PubMed ID: 25579920
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The effect of cathodic electrochemical potential of Ti-6Al-4V on cell viability: voltage threshold and time dependence.
    Sivan S; Kaul S; Gilbert JL
    J Biomed Mater Res B Appl Biomater; 2013 Nov; 101(8):1489-97. PubMed ID: 23894023
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Electrochemical behavior of titanium in artificial saliva: influence of pH.
    Abey S; Mathew MT; Lee DJ; Knoernschild KL; Wimmer MA; Sukotjo C
    J Oral Implantol; 2014 Feb; 40(1):3-10. PubMed ID: 22103963
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Electrochemical properties of suprastructures galvanically coupled to a titanium implant.
    Oh KT; Kim KN
    J Biomed Mater Res B Appl Biomater; 2004 Aug; 70(2):318-31. PubMed ID: 15264315
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Determinants of corrosion resistance of Ti-6Al-4V alloy dental implants in an In Vitro model of peri-implant inflammation.
    Berbel LO; Banczek EDP; Karoussis IK; Kotsakis GA; Costa I
    PLoS One; 2019; 14(1):e0210530. PubMed ID: 30703125
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Potential and frequency effects on fretting corrosion of Ti6Al4V and CoCrMo surfaces.
    Swaminathan V; Gilbert JL
    J Biomed Mater Res A; 2013 Sep; 101(9):2602-12. PubMed ID: 23404905
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Corrosion behavior of micro-arc oxidation film on titanium in simulated body fluid].
    Sun GL; Chen JZ; Wang L; Shi YL
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2007 Aug; 42(8):501-4. PubMed ID: 18001597
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Electrochemical behavior of titanium exposed to a biofilm supplemented with different sucrose concentrations.
    Souza JGS; Beline T; Matos AO; Costa Oliveira BE; Ricomini-Filho AP; Barão VAR
    J Prosthet Dent; 2018 Aug; 120(2):290-298. PubMed ID: 29551382
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Study of corrosion between a titanium implant and dental alloys.
    Reclaru L; Meyer JM
    J Dent; 1994 Jun; 22(3):159-68. PubMed ID: 8027459
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Potentiodynamic polarization study of the corrosion behavior of palladium-silver dental alloys.
    Sun D; Brantley WA; Frankel GS; Heshmati RH; Johnston WM
    J Prosthet Dent; 2018 Apr; 119(4):650-656. PubMed ID: 28965676
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Electrochemical characterization of cast titanium alloys.
    Cai Z; Shafer T; Watanabe I; Nunn ME; Okabe T
    Biomaterials; 2003 Jan; 24(2):213-8. PubMed ID: 12419621
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [The research of using TiN nanometer film to improve the anticorrosive property of FeCrMo alloy].
    Sun SY; Zhao YM; Zhang YM; Gao B; Li GM
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2003 Sep; 38(5):387-9. PubMed ID: 14746329
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Corrosion behavior of surface modifications on titanium dental implant. In situ bacteria monitoring by electrochemical techniques.
    Díaz I; Pacha-Olivenza MÁ; Tejero R; Anitua E; González-Martín ML; Escudero ML; García-Alonso MC
    J Biomed Mater Res B Appl Biomater; 2018 Apr; 106(3):997-1009. PubMed ID: 28480611
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.