515 related articles for article (PubMed ID: 24612524)
1. Stainless steel versus titanium volar multi-axial locking plates for fixation of distal radius fractures: a randomised clinical trial.
Couzens GB; Peters SE; Cutbush K; Hope B; Taylor F; James CD; Rankin CR; Ross M
BMC Musculoskelet Disord; 2014 Mar; 15():74. PubMed ID: 24612524
[TBL] [Abstract][Full Text] [Related]
2. Biomechanical Comparison of Volar Fixed-Angle Locking Plates for AO C3 Distal Radius Fractures: Titanium Versus Stainless Steel With Compression.
Marshall T; Momaya A; Eberhardt A; Chaudhari N; Hunt TR
J Hand Surg Am; 2015 Oct; 40(10):2032-8. PubMed ID: 26253601
[TBL] [Abstract][Full Text] [Related]
3. Comparison between Carbon-Peek volar locking plates and titanium volar locking plates in the treatment of distal radius fractures.
Perugia D; Guzzini M; Mazza D; Iorio C; Civitenga C; Ferretti A
Injury; 2017 Oct; 48 Suppl 3():S24-S29. PubMed ID: 29025605
[TBL] [Abstract][Full Text] [Related]
4. [Multidirectional screw fixation in the treatment of distal radius fractures using angle-stable plates].
Vlček M; Landor I; Višňa P; Vavřík P; Sindelářová J; Sosna A
Acta Chir Orthop Traumatol Cech; 2011; 78(1):27-33. PubMed ID: 21375962
[TBL] [Abstract][Full Text] [Related]
5. Biomechanical comparison between stainless steel, titanium and carbon-fiber reinforced polyetheretherketone volar locking plates for distal radius fractures.
Mugnai R; Tarallo L; Capra F; Catani F
Orthop Traumatol Surg Res; 2018 Oct; 104(6):877-882. PubMed ID: 29807189
[TBL] [Abstract][Full Text] [Related]
6. Comparison of functional outcome after volar plate fixation with 2.4-mm titanium versus 3.5-mm stainless-steel plate for extra-articular fracture of distal radius.
Souer JS; Ring D; Matschke S; Audige L; Maren-Hubert M; Jupiter J
J Hand Surg Am; 2010 Mar; 35(3):398-405. PubMed ID: 20138716
[TBL] [Abstract][Full Text] [Related]
7. [Clinical and radiological results after distal radius fracture: intramedullary locking nail versus volar locking plate osteosynthesis].
Lerch S; Sextro HG; Wilken F; Wittenberg CE
Z Orthop Unfall; 2009; 147(5):547-52. PubMed ID: 19806521
[TBL] [Abstract][Full Text] [Related]
8. Unstable distal radial fractures treated with external fixation, a radial column plate, or a volar plate. A prospective randomized trial.
Wei DH; Raizman NM; Bottino CJ; Jobin CM; Strauch RJ; Rosenwasser MP
J Bone Joint Surg Am; 2009 Jul; 91(7):1568-77. PubMed ID: 19571078
[TBL] [Abstract][Full Text] [Related]
9. POWIFF- Prospective study of wrist internal fixation of fracture: A protocol for a single centre, superiority, randomised controlled trial to study the efficacy of the VRP (2.0) distal radius plate (Austofix) versus the VA-LCP (Depuy-Synthes) for distal radius fractures.
Varghese VD; Smitham P; Howell S; Edwards S; Rickman M
BMC Musculoskelet Disord; 2018 Apr; 19(1):131. PubMed ID: 29712566
[TBL] [Abstract][Full Text] [Related]
10. Dorsal and volar 2.4-mm titanium locking plate fixation for AO type C3 dorsally comminuted distal radius fractures.
Chou YC; Chen AC; Chen CY; Hsu YH; Wu CC
J Hand Surg Am; 2011 Jun; 36(6):974-81. PubMed ID: 21549526
[TBL] [Abstract][Full Text] [Related]
11. Surgery versus conservative treatment in patients with type A distal radius fractures, a randomized controlled trial.
Walenkamp MM; Goslings JC; Beumer A; Haverlag R; Leenhouts PA; Verleisdonk EJ; Liem RS; Sintenie JB; Bronkhorst MW; Winkelhagen J; Schep NW
BMC Musculoskelet Disord; 2014 Mar; 15():90. PubMed ID: 24642190
[TBL] [Abstract][Full Text] [Related]
12. Are Volar Locking Plates Superior to Percutaneous K-wires for Distal Radius Fractures? A Meta-analysis.
Chaudhry H; Kleinlugtenbelt YV; Mundi R; Ristevski B; Goslings JC; Bhandari M
Clin Orthop Relat Res; 2015 Sep; 473(9):3017-27. PubMed ID: 25981715
[TBL] [Abstract][Full Text] [Related]
13. Volar Locking Plate or External Fixation With Optional Addition of K-Wires for Dorsally Displaced Distal Radius Fractures: A Randomized Controlled Study.
Mellstrand Navarro C; Ahrengart L; Törnqvist H; Ponzer S
J Orthop Trauma; 2016 Apr; 30(4):217-24. PubMed ID: 26709818
[TBL] [Abstract][Full Text] [Related]
14. Volar locking plates versus external fixation and adjuvant pin fixation in unstable distal radius fractures: a randomized, controlled study.
Williksen JH; Frihagen F; Hellund JC; Kvernmo HD; Husby T
J Hand Surg Am; 2013 Aug; 38(8):1469-76. PubMed ID: 23890493
[TBL] [Abstract][Full Text] [Related]
15. Open reduction internal fixation versus percutaneous pinning with external fixation of distal radius fractures: a prospective, randomized clinical trial.
Grewal R; MacDermid JC; King GJ; Faber KJ
J Hand Surg Am; 2011 Dec; 36(12):1899-906. PubMed ID: 22051229
[TBL] [Abstract][Full Text] [Related]
16. Effect of calcium phosphate bone cement augmentation on volar plate fixation of unstable distal radial fractures in the elderly.
Kim JK; Koh YD; Kook SH
J Bone Joint Surg Am; 2011 Apr; 93(7):609-14. PubMed ID: 21471414
[TBL] [Abstract][Full Text] [Related]
17. Complications of low-profile dorsal versus volar locking plates in the distal radius: a comparative study.
Yu YR; Makhni MC; Tabrizi S; Rozental TD; Mundanthanam G; Day CS
J Hand Surg Am; 2011 Jul; 36(7):1135-41. PubMed ID: 21712136
[TBL] [Abstract][Full Text] [Related]
18. Results of volar locking plating for unstable distal radius fractures.
Sügün TS; Gürbüz Y; Ozaksar K; Toros T; Kayalar M; Bal E
Acta Orthop Traumatol Turc; 2012; 46(1):22-5. PubMed ID: 22441447
[TBL] [Abstract][Full Text] [Related]
19. Functional outcome of unstable distal radius fractures: ORIF with a volar fixed-angle tine plate versus external fixation.
Wright TW; Horodyski M; Smith DW
J Hand Surg Am; 2005 Mar; 30(2):289-99. PubMed ID: 15781351
[TBL] [Abstract][Full Text] [Related]
20. Fixation of dorsally displaced distal radius fractures with volar plate.
Othman AY
J Trauma; 2009 May; 66(5):1416-20. PubMed ID: 19430247
[TBL] [Abstract][Full Text] [Related]