183 related articles for article (PubMed ID: 24613812)
1. Statistical modeling approach to quantitative analysis of interobserver variability in breast contouring.
Yang J; Woodward WA; Reed VK; Strom EA; Perkins GH; Tereffe W; Buchholz TA; Zhang L; Balter P; Court LE; Li XA; Dong L
Int J Radiat Oncol Biol Phys; 2014 May; 89(1):214-21. PubMed ID: 24613812
[TBL] [Abstract][Full Text] [Related]
2. Automatic segmentation of whole breast using atlas approach and deformable image registration.
Reed VK; Woodward WA; Zhang L; Strom EA; Perkins GH; Tereffe W; Oh JL; Yu TK; Bedrosian I; Whitman GJ; Buchholz TA; Dong L
Int J Radiat Oncol Biol Phys; 2009 Apr; 73(5):1493-500. PubMed ID: 18804333
[TBL] [Abstract][Full Text] [Related]
3. Upper abdominal normal organ contouring guidelines and atlas: a Radiation Therapy Oncology Group consensus.
Jabbour SK; Hashem SA; Bosch W; Kim TK; Finkelstein SE; Anderson BM; Ben-Josef E; Crane CH; Goodman KA; Haddock MG; Herman JM; Hong TS; Kachnic LA; Mamon HJ; Pantarotto JR; Dawson LA
Pract Radiat Oncol; 2014; 4(2):82-89. PubMed ID: 24890348
[TBL] [Abstract][Full Text] [Related]
4. Interobserver variability in clinical target volume delineation in tangential breast irradiation: a comparison between radiation oncologists and radiation therapists.
Batumalai V; Koh ES; Delaney GP; Holloway LC; Jameson MG; Papadatos G; Lonergan DM
Clin Oncol (R Coll Radiol); 2011 Mar; 23(2):108-13. PubMed ID: 21093228
[TBL] [Abstract][Full Text] [Related]
5. Variability of target and normal structure delineation for breast cancer radiotherapy: an RTOG Multi-Institutional and Multiobserver Study.
Li XA; Tai A; Arthur DW; Buchholz TA; Macdonald S; Marks LB; Moran JM; Pierce LJ; Rabinovitch R; Taghian A; Vicini F; Woodward W; White JR;
Int J Radiat Oncol Biol Phys; 2009 Mar; 73(3):944-51. PubMed ID: 19215827
[TBL] [Abstract][Full Text] [Related]
6. Contouring variability of human- and deformable-generated contours in radiotherapy for prostate cancer.
Gardner SJ; Wen N; Kim J; Liu C; Pradhan D; Aref I; Cattaneo R; Vance S; Movsas B; Chetty IJ; Elshaikh MA
Phys Med Biol; 2015 Jun; 60(11):4429-47. PubMed ID: 25988718
[TBL] [Abstract][Full Text] [Related]
7. Retroperitoneal Sarcoma Target Volume and Organ at Risk Contour Delineation Agreement Among NRG Sarcoma Radiation Oncologists.
Baldini EH; Abrams RA; Bosch W; Roberge D; Haas RLM; Catton CN; Indelicato DJ; Olsen JR; Deville C; Chen YL; Finkelstein SE; DeLaney TF; Wang D
Int J Radiat Oncol Biol Phys; 2015 Aug; 92(5):1053-1059. PubMed ID: 26194680
[TBL] [Abstract][Full Text] [Related]
8. Evaluation of dosimetric consequences of seroma contour variability in accelerated partial breast irradiation using a constructed representative seroma contour.
Kosztyla R; Olson R; Carolan H; Balkwill S; Moiseenko V; Kwan W
Int J Radiat Oncol Biol Phys; 2012 Oct; 84(2):527-32. PubMed ID: 22342091
[TBL] [Abstract][Full Text] [Related]
9. The effect of contouring variability on dosimetric parameters for brain metastases treated with stereotactic radiosurgery.
Stanley J; Dunscombe P; Lau H; Burns P; Lim G; Liu HW; Nordal R; Starreveld Y; Valev B; Voroney JP; Spencer DP
Int J Radiat Oncol Biol Phys; 2013 Dec; 87(5):924-31. PubMed ID: 24267967
[TBL] [Abstract][Full Text] [Related]
10. Categorizing segmentation quality using a quantitative quality assurance algorithm.
Rodrigues G; Louie A; Videtic G; Best L; Patil N; Hallock A; Gaede S; Kempe J; Battista J; de Haan P; Bauman G
J Med Imaging Radiat Oncol; 2012 Dec; 56(6):668-78. PubMed ID: 23210588
[TBL] [Abstract][Full Text] [Related]
11. Deformable image registration and interobserver variation in contour propagation for radiation therapy planning.
Riegel AC; Antone JG; Zhang H; Jain P; Raince J; Rea A; Bergamo AM; Kapur A; Potters L
J Appl Clin Med Phys; 2016 May; 17(3):347-357. PubMed ID: 27167289
[TBL] [Abstract][Full Text] [Related]
12. 3D ultrasound can contribute to planning CT to define the target for partial breast radiotherapy.
Berrang TS; Truong PT; Popescu C; Drever L; Kader HA; Hilts ML; Mitchell T; Soh SY; Sands L; Silver S; Olivotto IA
Int J Radiat Oncol Biol Phys; 2009 Feb; 73(2):375-83. PubMed ID: 18692322
[TBL] [Abstract][Full Text] [Related]
13. Interobserver variations of target volume delineation in multicatheter partial breast brachytherapy after open cavity surgery.
Major T; Gutiérrez C; Guix B; Mózsa E; Hannoun-Levi JM; Lössl K; Niehoff P; Resch A; van Limbergen E; Polgár C
Brachytherapy; 2015; 14(6):925-32. PubMed ID: 26209477
[TBL] [Abstract][Full Text] [Related]
14. Use of a novel atlas for muscles of mastication to reduce inter observer variability in head and neck radiotherapy contouring.
Hague C; Beasley W; Dixon L; Gaito S; Garcez K; Green A; Lee LW; Maranzano M; McPartlin A; Mistry H; Mullan D; Sykes AJ; Thomson D; Van Herk M; West CM; Slevin N
Radiother Oncol; 2019 Jan; 130():56-61. PubMed ID: 30420234
[TBL] [Abstract][Full Text] [Related]
15. A simplified CT-based definition of the supraclavicular and infraclavicular nodal volumes in breast cancer.
Atean I; Pointreau Y; Ouldamer L; Monghal C; Bougnoux A; Bera G; Barillot I
Cancer Radiother; 2013 Feb; 17(1):39-43. PubMed ID: 23333457
[TBL] [Abstract][Full Text] [Related]
16. Contouring variations and the role of atlas in non-small cell lung cancer radiation therapy: Analysis of a multi-institutional preclinical trial planning study.
Cui Y; Chen W; Kong FM; Olsen LA; Beatty RE; Maxim PG; Ritter T; Sohn JW; Higgins J; Galvin JM; Xiao Y
Pract Radiat Oncol; 2015; 5(2):e67-75. PubMed ID: 25413413
[TBL] [Abstract][Full Text] [Related]
17. Development of Prostate Bed Delineation Consensus Guidelines for Magnetic Resonance Image-Guided Radiotherapy and Assessment of Its Effect on Interobserver Variability.
Sritharan K; Akhiat H; Cahill D; Choi S; Choudhury A; Chung P; Diaz J; Dysager L; Hall W; Huddart R; Kerkmeijer LGW; Lawton C; Mohajer J; Murray J; Nyborg CJ; Pos FJ; Rigo M; Schytte T; Sidhom M; Sohaib A; Tan A; van der Voort van Zyp J; Vesprini D; Zelefsky MJ; Tree AC
Int J Radiat Oncol Biol Phys; 2024 Feb; 118(2):378-389. PubMed ID: 37633499
[TBL] [Abstract][Full Text] [Related]
18. Consensus Recommendations for Radiation Therapy Contouring and Treatment of Vulvar Carcinoma.
Gaffney DK; King B; Viswanathan AN; Barkati M; Beriwal S; Eifel P; Erickson B; Fyles A; Goulart J; Harkenrider M; Jhingran A; Klopp A; Koh WJ; Lim K; Petersen I; Portelance L; Small W; Stewart A; Wiebe E; Wolfson A; Yashar C; Bosch W
Int J Radiat Oncol Biol Phys; 2016 Jul; 95(4):1191-200. PubMed ID: 27130794
[TBL] [Abstract][Full Text] [Related]
19. Magnetic resonance imaging for prostate bed radiotherapy planning: An inter- and intra-observer variability study.
Barkati M; Simard D; Taussky D; Delouya G
J Med Imaging Radiat Oncol; 2016 Apr; 60(2):255-9. PubMed ID: 26568515
[TBL] [Abstract][Full Text] [Related]
20. Evaluation of a commercial DIR platform for contour propagation in prostate cancer patients treated with IMRT/VMAT.
Hammers JE; Pirozzi S; Lindsay D; Kaidar-Person O; Tan X; Chen RC; Das SK; Mavroidis P
J Appl Clin Med Phys; 2020 Feb; 21(2):14-25. PubMed ID: 32058663
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]