These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 24614881)

  • 21. Accuracy of Different Implant Impression Techniques: Evaluation of New Tray Design Concept.
    Liu DY; Cader FN; Abduo J; Palamara J
    J Prosthodont; 2019 Feb; 28(2):e682-e687. PubMed ID: 29286181
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effects of implant angulation, impression material, and variation in arch curvature width on implant transfer model accuracy.
    Akalin ZF; Ozkan YK; Ekerim A
    Int J Oral Maxillofac Implants; 2013; 28(1):149-57. PubMed ID: 23377060
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Accuracy of 2 impression techniques for ITI implants.
    Akça K; Cehreli MC
    Int J Oral Maxillofac Implants; 2004; 19(4):517-23. PubMed ID: 15346748
    [TBL] [Abstract][Full Text] [Related]  

  • 24. An in vitro evaluation of impression techniques for multiple internal- and external-connection implant prostheses.
    Vigolo P; Mutinelli S; Fonzi F; Stellini E
    Int J Oral Maxillofac Implants; 2014; 29(4):807-18. PubMed ID: 25032760
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Accuracy of impressions with different impression materials in angulated implants.
    Reddy S; Prasad K; Vakil H; Jain A; Chowdhary R
    Niger J Clin Pract; 2013; 16(3):279-84. PubMed ID: 23771446
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effect of implant angulation and impression technique on impressions of NobelActive implants.
    Alexander Hazboun GB; Masri R; Romberg E; Kempler J; Driscoll CF
    J Prosthet Dent; 2015 May; 113(5):425-31. PubMed ID: 25749089
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Accuracy of impression techniques for an implant-supported prosthesis.
    Del'Acqua MA; Chávez AM; Compagnoni MA; Molo Fde A
    Int J Oral Maxillofac Implants; 2010; 25(4):715-21. PubMed ID: 20657866
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Effect of Implant Angulation and Depth on the Accuracy of Casts Using the Open Tray Splinted Impression Technique.
    Taduri T; Mathur S; Upadhyay S; Patel K; Shah M
    J Oral Implantol; 2021 Dec; 47(6):447-454. PubMed ID: 33270885
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Accuracy of impression techniques for implants. Part 2 - comparison of splinting techniques.
    Filho HG; Mazaro JV; Vedovatto E; Assunção WG; dos Santos PH
    J Prosthodont; 2009 Feb; 18(2):172-6. PubMed ID: 19178624
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Accuracy of different impression techniques for internal-connection implants.
    Lee YJ; Heo SJ; Koak JY; Kim SK
    Int J Oral Maxillofac Implants; 2009; 24(5):823-30. PubMed ID: 19865622
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Accuracy of impressions for internal-connection implant prostheses with various divergent angles.
    Jang HK; Kim S; Shim JS; Lee KW; Moon HS
    Int J Oral Maxillofac Implants; 2011; 26(5):1011-5. PubMed ID: 22010084
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Evaluation of the accuracy of three techniques used for multiple implant abutment impressions.
    Vigolo P; Majzoub Z; Cordioli G
    J Prosthet Dent; 2003 Feb; 89(2):186-92. PubMed ID: 12616240
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Comparative evaluation of the effects of implant position, impression material, and tray type on implant impression accuracy.
    Gökçen-Rohlig B; Ongül D; Sancakli E; Sermet B
    Implant Dent; 2014 Jun; 23(3):283-8. PubMed ID: 24844388
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Accuracy of impression scanning compared with stone casts of implant impressions.
    Matta RE; Adler W; Wichmann M; Heckmann SM
    J Prosthet Dent; 2017 Apr; 117(4):507-512. PubMed ID: 27881327
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Effect of Splinting on Dimensional Accuracy of Impressions Made of Implants with Different Subgingival Alignments.
    Beyabanaki E; Shamshiri AR; Alikhasi M; Monzavi A
    J Prosthodont; 2017 Jan; 26(1):48-55. PubMed ID: 26436559
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Three-dimensional accuracy of different impression techniques for dental implants.
    Nakhaei M; Madani AS; Moraditalab A; Haghi HR
    Dent Res J (Isfahan); 2015; 12(5):431-7. PubMed ID: 26604956
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Can transfer type and implant angulation affect impression accuracy? A 3D in vitro evaluation.
    Farronato D; Pasini PM; Campana V; Lops D; Azzi L; Manfredini M
    Odontology; 2021 Oct; 109(4):884-894. PubMed ID: 34075492
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Accuracy of open tray implant impressions: an in vitro comparison of stock versus custom trays.
    Burns J; Palmer R; Howe L; Wilson R
    J Prosthet Dent; 2003 Mar; 89(3):250-5. PubMed ID: 12644799
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Accuracy of definitive casts using 4 implant-level impression techniques in a scenario of multi-implant system with different implant angulations and subgingival alignment levels.
    Martínez-Rus F; García C; Santamaría A; Özcan M; Pradíes G
    Implant Dent; 2013 Jun; 22(3):268-76. PubMed ID: 23615660
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Accuracy of implant impressions without impression copings: a three-dimensional analysis.
    Kwon JH; Son YH; Han CH; Kim S
    J Prosthet Dent; 2011 Jun; 105(6):367-73. PubMed ID: 21640237
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.