These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 2462217)

  • 1. P-wave sensing in VVI pacemakers: useful or a problem?
    van Gelder LM; el Gamal MI; Tielen CH
    Pacing Clin Electrophysiol; 1988 Oct; 11(10):1413-8. PubMed ID: 2462217
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Efficacy and safety of bipolar sensing with high atrial sensitivity in dual chamber pacemakers.
    Wiegand UK; Bode F; Peters W; Haase H; Bonnemeier H; Katus HA; Potratz J
    Pacing Clin Electrophysiol; 2000 Apr; 23(4 Pt 1):427-33. PubMed ID: 10793429
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bipolar ventricular far-field signals in the atrium.
    Fröhlig G; Helwani Z; Kusch O; Berg M; Schieffer H
    Pacing Clin Electrophysiol; 1999 Nov; 22(11):1604-13. PubMed ID: 10598963
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparative evaluation of acute and long-term clinical performance of two single lead atrial synchronous ventricular (VDD) pacemakers: diagonally arranged bipolar versus closely spaced bipolar ring electrodes.
    Lau CP; Leung SK; Lee IS
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 1):1574-81. PubMed ID: 8946453
    [TBL] [Abstract][Full Text] [Related]  

  • 5. P wave oversensing in a unipolar VVI pacemaker.
    van Gelder BM; Bracke FA; El Gamal MI
    Pacing Clin Electrophysiol; 1995 Feb; 18(2):370-3. PubMed ID: 7731887
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Suppression of ventricular output by noise in the atrial channel in a dual chamber pacemaker.
    Ben-Zur UM; Kahn S; Gross JN; Platt SB; Goodfriend MA; Furman S
    Pacing Clin Electrophysiol; 1995 Aug; 18(8):1586-8. PubMed ID: 7479181
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ventricular capture by anodal pacemaker stimulation.
    Occhetta E; Bortnik M; Marino P
    Europace; 2006 May; 8(5):385-7. PubMed ID: 16636000
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Oversensing from electrode 'chatter' in a bipolar pacing lead: a case report.
    Chew PH; Brinker JA
    Pacing Clin Electrophysiol; 1990 Jun; 13(6):808-11. PubMed ID: 1695361
    [TBL] [Abstract][Full Text] [Related]  

  • 9. VDD(R) pacing: short- and long-term stability of atrial sensing with a single lead system.
    Naegeli B; Osswald S; Pfisterer M; Burkart F
    Pacing Clin Electrophysiol; 1996 Apr; 19(4 Pt 1):455-64. PubMed ID: 8848393
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Self-inhibition of an AV sequential demand (DVI) pulse generator due to polyurethane lead insulation disruption.
    Sanford CF
    Pacing Clin Electrophysiol; 1983 Sep; 6(5 Pt 1):840-4. PubMed ID: 6195602
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Arrhythmia resulting from sensing malfunction in a P wave triggered pacemaker.
    Curtis GP; Lief LH
    J Electrocardiol; 1980 Oct; 13(4):401-4. PubMed ID: 7430871
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Efficacy of single lead VDD pacing in patients with impaired and normal left ventricular function.
    Schuchert A; Jakob M; Treese N; Schöpfel A; Schmidt W; Jung W; Kreuzer J; Staedt U; Stertmann WA; Meinertz T
    Pacing Clin Electrophysiol; 2000 Aug; 23(8):1263-7. PubMed ID: 10962749
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Atrial fibrillation in patients with permanent VVI pacemakers: risk factors for atrial fibrillation.
    Cho JG; Jeong YH; Cho IJ; Ahn YG; Cha KS; Seo JP; Park JH; Jeong MH; Park JC; Kang JC
    Korean J Intern Med; 1997 Jan; 12(1):34-8. PubMed ID: 9159035
    [TBL] [Abstract][Full Text] [Related]  

  • 14. False inhibition of an atrial demand pacemaker caused by an insulation defect in a polyurethane lead.
    van Gelder LM; El Gamal MI
    Pacing Clin Electrophysiol; 1983 Sep; 6(5 Pt 1):834-9. PubMed ID: 6195601
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [P wave changes and atrial fibrillation after implantation of VVI type pacemaker].
    Snoeck J; Decoster H; Marchand X; Kahn JC; Baron B; Zannier D; Pathé M; Verherstraeten M; Vrints C; Heuten H
    Arch Mal Coeur Vaiss; 1992 Oct; 85(10):1419-24. PubMed ID: 1297290
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Usefulness of transcutaneous triggering of conventional implanted pulse generators by an activity-sensing pacemaker for predicting effectiveness of rate response pacing.
    Fetter J; Benditt DG; Mianulli M
    Am J Cardiol; 1988 Nov; 62(13):901-5. PubMed ID: 3177238
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Assessment of the work capacity and relationship between rate response and exercise tolerance associated with activity-sensing rate-responsive ventricular pacing.
    Faerestrand S; Breivik K; Ohm OJ
    Pacing Clin Electrophysiol; 1987 Nov; 10(6):1277-90. PubMed ID: 2446275
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Atrial synchronous ventricular inhibited pacing (VDD): an underutilized mode of pacing.
    Messenger JC; Greenberg PS; Warren J; Castellanet MJ
    Pacing Clin Electrophysiol; 1983 Mar; 6(2 Pt 2):392-8. PubMed ID: 6189084
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Should unipolar leads be implanted in the atrium? A Holter electrocardiographic comparison of threshold adapted unipolar and high sensitive bipolar sensing.
    Wiegand UK; Schier H; Bode F; Brandes A; Potratz J
    Pacing Clin Electrophysiol; 1998 Aug; 21(8):1601-8. PubMed ID: 9725160
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Experience and implantation techniques with a new single-pass lead VDD pacing system.
    Longo E; Catrini V
    Pacing Clin Electrophysiol; 1990 Jul; 13(7):927-36. PubMed ID: 1695750
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.