These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
41 related articles for article (PubMed ID: 2462218)
1. Pseudo repetitive non-reentrant ventriculoatrial synchrony: Current challenges. Gjermeni E; Doering M; Hindricks G; Bode K Pacing Clin Electrophysiol; 2023 Jun; 46(6):467-474. PubMed ID: 36635217 [TBL] [Abstract][Full Text] [Related]
2. Case of a misleading ECG. Shahab A; Mahmood UA; Noheria A J Electrocardiol; 2024; 82():113-117. PubMed ID: 38118295 [TBL] [Abstract][Full Text] [Related]
3. Active periodic electrograms in remote monitoring of pacemaker recipients: the PREMS study. Lazarus A; Guy-Moyat B; Mondoly P; Pons F; Quaglia C; Elkaim JP; Bayle S; Victor F Europace; 2019 Jan; 21(1):130-136. PubMed ID: 29955890 [TBL] [Abstract][Full Text] [Related]
4. Inadvertent left ventricular pacing due to lead malpositioning, incidentally discovered seventeen years later. Bobat S; How WJ BMJ Case Rep; 2021 Nov; 14(11):. PubMed ID: 34848421 [TBL] [Abstract][Full Text] [Related]
5. The power of three: Atrial rate limit power-on-reset - A non-electromagnetic cause of pacemaker-induced extracardiac stimulation. Torbey E; Sharma E; Betzold R; Mehta C; Vogt B; Chu A Pacing Clin Electrophysiol; 2024 Jan; 47(1):113-116. PubMed ID: 37310105 [TBL] [Abstract][Full Text] [Related]
6. Sensing of concealed ventricular extrasystoles by pacemakers. Fifty years later. Barold SS; Kucher A J Cardiovasc Electrophysiol; 2023 Dec; 34(12):2607-2612. PubMed ID: 37964511 [TBL] [Abstract][Full Text] [Related]
7. Pacing-induced R-on-T phenomenon: What is the mechanism? Mondal S; Vijay J; Namboodiri N Pacing Clin Electrophysiol; 2024 May; 47(5):650-652. PubMed ID: 38563727 [No Abstract] [Full Text] [Related]
8. [Electrophysiological study with a dual chamber pacemaker]. Bogossian H; Bimpong-Buta NY; Robl S; Iliodromitis K Herzschrittmacherther Elektrophysiol; 2024 Mar; 35(1):80-82. PubMed ID: 38305879 [No Abstract] [Full Text] [Related]
16. Utility of the atrial endocardial electrogram concurrent with dual-chamber pacing in the determination of a pacemaker-mediated arrhythmia. Shandling AH; Castellanet MJ; Messenger JC; Brownlee RR Pacing Clin Electrophysiol; 1988 Oct; 11(10):1419-25. PubMed ID: 2462218 [TBL] [Abstract][Full Text] [Related]
17. Questionable dysfunction of a dual-Chamber pacemaker in a 17-year-old female: differential diagnoses of missing ventricular beats. Lehmann G; Kolb C Int J Cardiol; 2004 Dec; 97(3):567-9. PubMed ID: 15561353 [TBL] [Abstract][Full Text] [Related]