These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Prevention and termination of pacemaker-mediated tachycardia in a new DDD pacing system (Siemens-Pacesetter model 2010T). Duncan JL; Clark MF Pacing Clin Electrophysiol; 1988 Nov; 11(11 Pt 2):1679-83. PubMed ID: 2463532 [TBL] [Abstract][Full Text] [Related]
3. A new algorithm for a high level of protection against pacemaker-mediated tachycardia. Lamaison D; Girodo S; Limousin M Pacing Clin Electrophysiol; 1988 Nov; 11(11 Pt 2):1715-21. PubMed ID: 2463539 [TBL] [Abstract][Full Text] [Related]
4. Atrial arrhythmia management with sensor controlled atrial refractory period and automatic mode switching in patients with minute ventilation sensing dual chamber rate adaptive pacemakers. Lau CP; Tai YT; Fong PC; Li JP; Chung FL Pacing Clin Electrophysiol; 1992 Oct; 15(10 Pt 1):1504-14. PubMed ID: 1383962 [TBL] [Abstract][Full Text] [Related]
5. Pacemaker-Mediated Tachycardia: Manufacturer Specifics and Spectrum of Cases. Monteil B; Ploux S; Eschalier R; Ritter P; Haissaguerre M; Koneru JN; Ellenbogen KA; Bordachar P Pacing Clin Electrophysiol; 2015 Dec; 38(12):1489-98. PubMed ID: 26403498 [TBL] [Abstract][Full Text] [Related]
6. Differentiating pacemaker-mediated tachycardia from tachycardia due to atrial tracking: utility of V-A-A-V versus V-A-V response after postventricular atrial refractory period extension. Ip JE; Markowitz SM; Liu CF; Cheung JW; Thomas G; Lerman BB Heart Rhythm; 2011 Aug; 8(8):1185-91. PubMed ID: 21376834 [TBL] [Abstract][Full Text] [Related]
7. Functional atrial undersensing associated with switching to a tracking mode of pacing. Barold SS; Van Heuverswyn F; Timmers L; Stroobandt RX Pacing Clin Electrophysiol; 2012 Oct; 35(10):1188-93. PubMed ID: 22816428 [TBL] [Abstract][Full Text] [Related]
8. Cross-ventricular pacemaker-mediated tachycardia by myopotential induction during biventricular pacing. Guenoun M; Hero M; Roux O; Mainardis M Pacing Clin Electrophysiol; 2005 Jun; 28(6):585-7. PubMed ID: 15955194 [TBL] [Abstract][Full Text] [Related]
9. Use of a new fallback function to prevent endless-loop tachycardias: first clinical results. The Investigators of the Multicenter Study. Nitzsché R; Girodo S; Limousin M; Cazeau S Pacing Clin Electrophysiol; 1992 Nov; 15(11 Pt 2):1851-7. PubMed ID: 1437665 [TBL] [Abstract][Full Text] [Related]
10. Noninvasive evaluation of retrograde conduction times to avoid pacemaker-mediated tachycardia. Greenspon AJ; Greenberg RM J Am Coll Cardiol; 1985 Jun; 5(6):1403-6. PubMed ID: 3998322 [TBL] [Abstract][Full Text] [Related]
11. Clinical experience with a new multiprogrammable dual chamber pacemaker. Kutalek SP; Schuster MM; Hessen SE; Sheppard R; Maquilan M; Nydegger C Pacing Clin Electrophysiol; 1992 Nov; 15(11 Pt 2):1830-5. PubMed ID: 1279556 [TBL] [Abstract][Full Text] [Related]
12. Method of atrioventricular programming in atrial flutter in patients with biventricular pacemaker. Naqvi TZ; Barnett W Pacing Clin Electrophysiol; 2007 Aug; 30(8):948-56. PubMed ID: 17669076 [TBL] [Abstract][Full Text] [Related]
13. Noninvasive measurement of retrograde conduction times in pacemaker patients. Marco DD; Gallagher D Pacing Clin Electrophysiol; 1988 Nov; 11(11 Pt 2):1673-8. PubMed ID: 2463531 [TBL] [Abstract][Full Text] [Related]
14. Repetitive nonreentrant ventriculoatrial synchrony: An underrecognized cause of pacemaker-related arrhythmia. Sharma PS; Kaszala K; Tan AY; Koneru JN; Shepard R; Ellenbogen KA; Huizar JF Heart Rhythm; 2016 Aug; 13(8):1739-47. PubMed ID: 27050909 [TBL] [Abstract][Full Text] [Related]
15. [Mode-switching algorithms: programming and usefulness]. Israel CW Herz; 2001 Feb; 26(1):2-17. PubMed ID: 11258106 [TBL] [Abstract][Full Text] [Related]
17. Termination of pacemaker-mediated tachycardia by adenosine. Conti JB; Curtis AB; Hill JA; Raymenants ER Clin Cardiol; 1994 Jan; 17(1):47-8. PubMed ID: 8149683 [TBL] [Abstract][Full Text] [Related]
18. Validation of device algorithm to differentiate pacemaker-mediated tachycardia from tachycardia due to atrial tracking. Ip JE; Lerman BB Heart Rhythm; 2016 Aug; 13(8):1612-7. PubMed ID: 27108937 [TBL] [Abstract][Full Text] [Related]
19. Performance of a specific algorithm to minimize right ventricular pacing: A multicenter study. Strik M; Defaye P; Eschalier R; Mondoly P; Frontera A; Ritter P; Haïssaguerre M; Ploux S; Ellenbogen KA; Bordachar P Heart Rhythm; 2016 Jun; 13(6):1266-73. PubMed ID: 26899544 [TBL] [Abstract][Full Text] [Related]
20. The use of implantable sensors for the control of pacemaker mediated tachycardias: a comparative evaluation between minute ventilation sensing and acceleration sensing dual chamber rate adaptive pacemakers. Lau CP; Tai YT; Fong PC; Li JP; Chung FL; Song S Pacing Clin Electrophysiol; 1992 Jan; 15(1):34-44. PubMed ID: 1370998 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]