These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
151 related articles for article (PubMed ID: 24636170)
21. Open reduction and rigid internal fixation of mandibular condylar fractures by an intraoral approach: a long-term follow-up study of 15 patients. Jensen T; Jensen J; Nørholt SE; Dahl M; Lenk-Hansen L; Svensson P J Oral Maxillofac Surg; 2006 Dec; 64(12):1771-9. PubMed ID: 17113444 [TBL] [Abstract][Full Text] [Related]
22. Is the use of arch bars or interdental wire fixation necessary for successful outcomes in the open reduction and internal fixation of mandibular angle fractures? Bell RB; Wilson DM J Oral Maxillofac Surg; 2008 Oct; 66(10):2116-22. PubMed ID: 18848111 [TBL] [Abstract][Full Text] [Related]
23. Use of rectangular grid miniplates for fracture fixation at the mandibular angle. Hochuli-Vieira E; Ha TK; Pereira-Filho VA; Landes CA J Oral Maxillofac Surg; 2011 May; 69(5):1436-41. PubMed ID: 21216065 [TBL] [Abstract][Full Text] [Related]
24. Treatment methods for fractures of the mandibular angle. Ellis E J Craniomaxillofac Trauma; 1996; 2(1):28-36. PubMed ID: 11951472 [TBL] [Abstract][Full Text] [Related]
25. Comparison of miniplate versus lag-screw osteosynthesis for fractures of the mandibular angle. Schaaf H; Kaubruegge S; Streckbein P; Wilbrand JF; Kerkmann H; Howaldt HP Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2011 Jan; 111(1):34-40. PubMed ID: 20598593 [TBL] [Abstract][Full Text] [Related]
26. [Experimental studies of the biomechanical stability of different miniplate configurations for the mandibular angle]. Schierle HP; Schmelzeisen R; Rahn B Fortschr Kiefer Gesichtschir; 1996; 41():166-70. PubMed ID: 8755434 [TBL] [Abstract][Full Text] [Related]
27. Treatment of mandibular angle fractures - linea obliqua plate versus grid plate. Höfer SH; Ha L; Ballon A; Sader R; Landes C J Craniomaxillofac Surg; 2012 Dec; 40(8):807-11. PubMed ID: 22483950 [TBL] [Abstract][Full Text] [Related]
28. A comparative evaluation of osteosynthesis with lag screws, miniplates, or Kirschner wires for mandibular condylar process fractures. Sugiura T; Yamamoto K; Murakami K; Sugimura M J Oral Maxillofac Surg; 2001 Oct; 59(10):1161-8; discussion 1169-70. PubMed ID: 11573172 [TBL] [Abstract][Full Text] [Related]
29. Immediate mobilization following fixation of mandible fractures: a prospective, randomized study. Kaplan BA; Hoard MA; Park SS Laryngoscope; 2001 Sep; 111(9):1520-4. PubMed ID: 11572207 [TBL] [Abstract][Full Text] [Related]
30. Prospective randomized clinical trial comparing bite force in 2-mm locking plates versus 2-mm standard plates in treatment of mandibular fractures. Agarwal M; Mohammad S; Singh RK; Singh V J Oral Maxillofac Surg; 2011 Jul; 69(7):1995-2000. PubMed ID: 21272972 [TBL] [Abstract][Full Text] [Related]
31. Manual reduction of mandibular fractures before internal fixation leads to shorter operative duration and equivalent outcomes when compared with reduction with intermaxillary fixation. Hsu E; Crombie A; To P; Marquart L; Batstone MD J Oral Maxillofac Surg; 2012 Jul; 70(7):1622-6. PubMed ID: 22698294 [TBL] [Abstract][Full Text] [Related]
32. Comparative evaluation of 2.0-mm locking plate system vs 2.0-mm nonlocking plate system for mandibular fracture: a prospective randomized study. Singh V; Kumar I; Bhagol A Int J Oral Maxillofac Surg; 2011 Apr; 40(4):372-7. PubMed ID: 21194892 [TBL] [Abstract][Full Text] [Related]
33. Intraoral open reduction and internal fixation of displaced mandibular angle fractures using a specific ad hoc reduction-compression forceps: a preliminary study. Scolozzi P; Jaques B Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2008 Oct; 106(4):497-501. PubMed ID: 18547841 [TBL] [Abstract][Full Text] [Related]
34. [A comparative study of 2 series of mandibular osteosynthesis using screwed plates]. Jammet P; Souyris F; Atlan G; Dupoirieux L Rev Stomatol Chir Maxillofac; 1992; 93(2):76-9. PubMed ID: 1626191 [TBL] [Abstract][Full Text] [Related]
35. [Is miniplate osteosynthesis for combined mandibular body and bilateral mandibular condyle fractures adequate?]. Kerscher A; Vees-Höflsauer B; Kreusch T Fortschr Kiefer Gesichtschir; 1996; 41():61-3. PubMed ID: 8755401 [TBL] [Abstract][Full Text] [Related]
36. Treatment of mandible fractures using resorbable plates with a mean of 3 weeks maxillomandibular fixation: a prospective study. Vázquez-Morales DE; Dyalram-Silverberg D; Lazow SK; Berger JR Oral Surg Oral Med Oral Pathol Oral Radiol; 2013 Jan; 115(1):25-8. PubMed ID: 22921447 [TBL] [Abstract][Full Text] [Related]
37. Management of mandibular angle fractures using the mandibular angle reduction forceps. Choi BH; Kim HJ; Kim MK; Han SG; Huh JY; Kim BY; Zhu SJ; Jung JH Int J Oral Maxillofac Surg; 2005 May; 34(3):257-61. PubMed ID: 15741033 [TBL] [Abstract][Full Text] [Related]
38. A prospective trial of poly-L-lactic/polyglycolic acid co-polymer plates and screws for internal fixation of mandibular fractures. Ferretti C Int J Oral Maxillofac Surg; 2008 Mar; 37(3):242-8. PubMed ID: 18295449 [TBL] [Abstract][Full Text] [Related]
39. Intraoral external oblique ridge compared with transbuccal lateral cortical plate fixation for the treatment of fractures of the mandibular angle: prospective randomised trial. Laverick S; Siddappa P; Wong H; Patel P; Jones DC Br J Oral Maxillofac Surg; 2012 Jun; 50(4):344-9. PubMed ID: 22421389 [TBL] [Abstract][Full Text] [Related]
40. Comparison between three-dimensional and standard miniplates in the management of mandibular angle fractures: a prospective, randomized, double-blind, controlled clinical study. Al-Moraissi EA; Mounair RM; El-Sharkawy TM; El-Ghareeb TI Int J Oral Maxillofac Surg; 2015 Mar; 44(3):316-21. PubMed ID: 25457871 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]