These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 24645803)

  • 1. A method to noninvasively identify cardiac bioelectrical sources.
    Sohn K; Lv W; Lee K; Galea A; Hirschman G; Barrett C; Cohen RJ; Armoundas AA
    Pacing Clin Electrophysiol; 2014 Aug; 37(8):1038-50. PubMed ID: 24645803
    [TBL] [Abstract][Full Text] [Related]  

  • 2. On the efficiency and accuracy of the single equivalent moving dipole method to identify sites of cardiac electrical activation.
    Sohn K; Armoundas AA
    Med Biol Eng Comput; 2016 Oct; 54(10):1611-9. PubMed ID: 26798056
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The single equivalent moving dipole model does not require spatial anatomical information to determine cardiac sources of activation.
    Sohn K; Lv W; Lee K; Galea AM; Hirschman GB; Hayward AM; Cohen RJ; Armoundas AA
    IEEE J Biomed Health Inform; 2014 Jan; 18(1):222-30. PubMed ID: 24403420
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accuracy of cardiac ablation catheter guidance by means of a single equivalent moving dipole inverse algorithm to identify sites of origin of cardiac electrical activation.
    Lv W; Lee K; Arai T; Barrett CD; Hasan MM; Hayward AM; Marini RP; Barley ME; Galea A; Hirschman G; Armoundas AA; Cohen RJ
    J Interv Card Electrophysiol; 2020 Sep; 58(3):323-331. PubMed ID: 31456103
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Cardiac ablation catheter guidance by means of a single equivalent moving dipole inverse algorithm.
    Lee K; Lv W; Ter-Ovanesyan E; Barley ME; Voysey GE; Galea AM; Hirschman GB; Leroy K; Marini RP; Barrett C; Armoundas AA; Cohen RJ
    Pacing Clin Electrophysiol; 2013 Jul; 36(7):811-22. PubMed ID: 23448231
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Statistical accuracy of a moving equivalent dipole method to identify sites of origin of cardiac electrical activation.
    Armoundas AA; Feldman AB; Mukkamala R; He B; Mullen TJ; Belk PA; Lee YZ; Cohen RJ
    IEEE Trans Biomed Eng; 2003 Dec; 50(12):1360-70. PubMed ID: 14656065
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Method for guiding the ablation catheter to the ablation site: a simulation and experimental study.
    Fukuoka Y; Oostendorp TF; Armoundas AA
    Med Biol Eng Comput; 2009 Mar; 47(3):267-78. PubMed ID: 19194733
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A single equivalent moving dipole model: an efficient approach for localizing sites of origin of ventricular electrical activation.
    Armoundas AA; Feldman AB; Mukkamala R; Cohen RJ
    Ann Biomed Eng; 2003 May; 31(5):564-76. PubMed ID: 12757200
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Use of the inverse solution guidance algorithm method for RF ablation catheter guidance.
    Lv W; Barrett CD; Arai T; Bapat A; Armoundas AA; Cohen RJ; Lee K
    J Cardiovasc Electrophysiol; 2021 May; 32(5):1281-1289. PubMed ID: 33625757
    [TBL] [Abstract][Full Text] [Related]  

  • 10. High-precision guidance of ablation catheters to arrhythmic sites using electrocardiographic signals.
    Barley ME; Cohen RJ
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():6297-300. PubMed ID: 17945952
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Feasibility of Rapid Linear-Endocardial and Epicardial Ventricular Ablation Using an Irrigated Multipolar Radiofrequency Ablation Catheter.
    Nazer B; Walters TE; Duggirala S; Gerstenfeld EP
    Circ Arrhythm Electrophysiol; 2017 Mar; 10(3):. PubMed ID: 28288961
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dynamic registration of preablation imaging with a catheter geometry to guide ablation in a Swine model: validation of image integration and assessment of catheter navigation accuracy.
    West JJ; Patel AR; Kramer CM; Helms AS; Olson ES; Rangavajhala V; Ferguson JD
    J Cardiovasc Electrophysiol; 2010 Jan; 21(1):81-7. PubMed ID: 19682169
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Rapid 12-lead automated localization method: Comparison to electrocardiographic imaging (ECGI) in patient-specific geometry.
    Zhou S; Horáček BM; Warren JW; AbdelWahab A; Sapp JL
    J Electrocardiol; 2018; 51(6S):S92-S97. PubMed ID: 30177365
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Applicability of the single equivalent moving dipole model in an infinite homogeneous medium to identify cardiac electrical sources: a computer simulation study in a realistic anatomic geometry torso model.
    Fukuoka Y; Oostendorp TF; Sherman DA; Armoundas AA
    IEEE Trans Biomed Eng; 2006 Dec; 53(12 Pt 1):2436-44. PubMed ID: 17153200
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Electrical storm induced by cardiac resynchronization therapy is determined by pacing on epicardial scar and can be successfully managed by catheter ablation.
    Roque C; Trevisi N; Silberbauer J; Oloriz T; Mizuno H; Baratto F; Bisceglia C; Sora N; Marzi A; Radinovic A; Guarracini F; Vergara P; Sala S; Paglino G; Gulletta S; Mazzone P; Cireddu M; Maccabelli G; Della Bella P
    Circ Arrhythm Electrophysiol; 2014 Dec; 7(6):1064-9. PubMed ID: 25221332
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Radiofrequency catheter ablation of idiopathic ventricular arrhythmias originating from intramural foci in the left ventricular outflow tract: efficacy of sequential versus simultaneous unipolar catheter ablation.
    Yamada T; Maddox WR; McElderry HT; Doppalapudi H; Plumb VJ; Kay GN
    Circ Arrhythm Electrophysiol; 2015 Apr; 8(2):344-52. PubMed ID: 25637597
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Mapping epicardial fat with multi-detector computed tomography to facilitate percutaneous transepicardial arrhythmia ablation.
    Abbara S; Desai JC; Cury RC; Butler J; Nieman K; Reddy V
    Eur J Radiol; 2006 Mar; 57(3):417-22. PubMed ID: 16434161
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A method for guiding ablation catheters to arrhythmogenic sites using body surface electrocardiographic signals.
    Barley ME; Armoundas AA; Cohen RJ
    IEEE Trans Biomed Eng; 2009 Mar; 56(3):810-9. PubMed ID: 19272900
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Localization of ventricular activation origin using patient-specific geometry: Preliminary results.
    Zhou S; Sapp JL; AbdelWahab A; Šťovíček P; Horáček BM
    J Cardiovasc Electrophysiol; 2018 Jul; 29(7):979-986. PubMed ID: 29702740
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A comparison of simulated QRS isointegral maps resulting from pacing at adjacent sites: implications for the spatial resolution of pace mapping using body surface potentials.
    Hren R; Punske BB
    J Electrocardiol; 1998; 31 Suppl():135-44. PubMed ID: 9988019
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.