These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 24646399)

  • 1. Assessment of intrathoracic impedance algorithm in the pediatric and adult congenital population.
    Silva JN; VON Bergen NH; Dubin AM; Collins KK; Chen J; Bowman TM; Van Hare GF
    Pacing Clin Electrophysiol; 2014 Sep; 37(9):1174-80. PubMed ID: 24646399
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Utility of intrathoracic impedance monitoring in pediatric and congenital heart disease.
    LaPage MJ; von Alvensleben J; Dick M; Serwer G; Bradley DJ
    Pacing Clin Electrophysiol; 2013 Aug; 36(8):994-9. PubMed ID: 23594286
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Sensitivity and positive predictive value of implantable intrathoracic impedance monitoring as a predictor of heart failure hospitalizations: the SENSE-HF trial.
    Conraads VM; Tavazzi L; Santini M; Oliva F; Gerritse B; Yu CM; Cowie MR
    Eur Heart J; 2011 Sep; 32(18):2266-73. PubMed ID: 21362703
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Improved algorithm to detect fluid accumulation via intrathoracic impedance monitoring in heart failure patients with implantable devices.
    Sarkar S; Hettrick DA; Koehler J; Rogers T; Grinberg Y; Yu CM; Abraham WT; Small R; Tang WH
    J Card Fail; 2011 Jul; 17(7):569-76. PubMed ID: 21703529
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Refined heart failure detection algorithm for improved clinical reliability of OptiVol alerts in CRT-D recipients.
    Vamos M; Nyolczas N; Bari Z; Bogyi P; Muk B; Szabo B; Ancsin B; Kiss RG; Duray GZ
    Cardiol J; 2018; 25(2):236-244. PubMed ID: 28653309
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Intrathoracic impedance monitoring to predict decompensated heart failure.
    Ypenburg C; Bax JJ; van der Wall EE; Schalij MJ; van Erven L
    Am J Cardiol; 2007 Feb; 99(4):554-7. PubMed ID: 17293202
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The assessment of intrathoracic impedance algorithm in the pediatric and adult congenital population.
    LaPage MJ; Bradley DJ
    Pacing Clin Electrophysiol; 2015 Mar; 38(3):411. PubMed ID: 25652586
    [No Abstract]   [Full Text] [Related]  

  • 8. An improved algorithm calculated from intrathoracic impedance can precisely diagnose preclinical heart failure events: Sub-analysis of a multicenter MOMOTARO (Monitoring and Management of OptiVol Alert to Reduce Heart Failure Hospitalization) trial study.
    Miyoshi A; Nishii N; Kubo M; Okamoto Y; Fujii S; Watanabe A; Okawa K; Kawamoto K; Morita H; Ito H
    J Cardiol; 2017 Nov; 70(5):425-431. PubMed ID: 28673507
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Decreased Intrathoracic Impedance Associated With OptiVol Alert Can Diagnose Increased B-Type Natriuretic Peptide - MOMOTARO (Monitoring and Management of OptiVol Alert to Reduce Heart Failure Hospitalization) Study - .
    Nishii N; Kubo M; Okamoto Y; Fujii S; Watanabe A; Toyama Y; Yamada T; Doi M; Morita H; Ito H;
    Circ J; 2015; 79(6):1315-22. PubMed ID: 25787230
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intrathoracic impedance and pulmonary wedge pressure for the detection of heart failure deterioration.
    Maines M; Catanzariti D; Cirrincione C; Valsecchi S; Comisso J; Vergara G
    Europace; 2010 May; 12(5):680-5. PubMed ID: 20047927
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fundamentals of intrathoracic impedance monitoring in heart failure.
    Wang L
    Am J Cardiol; 2007 May; 99(10A):3G-10G. PubMed ID: 17512421
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Analysis of different device-based intrathoracic impedance vectors for detection of heart failure events (from the Detect Fluid Early from Intrathoracic Impedance Monitoring study).
    Heist EK; Herre JM; Binkley PF; Van Bakel AB; Porterfield JG; Porterfield LM; Qu F; Turkel M; Pavri BB;
    Am J Cardiol; 2014 Oct; 114(8):1249-56. PubMed ID: 25150135
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Clinical utility of intrathoracic impedance monitoring to alert patients with an implanted device of deteriorating chronic heart failure.
    Vollmann D; Nägele H; Schauerte P; Wiegand U; Butter C; Zanotto G; Quesada A; Guthmann A; Hill MR; Lamp B;
    Eur Heart J; 2007 Aug; 28(15):1835-40. PubMed ID: 17309902
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Rationale and design of a prospective trial to assess the sensitivity and positive predictive value of implantable intrathoracic impedance monitoring in the prediction of heart failure hospitalizations: the SENSE-HF study.
    Cowie MR; Conraads V; Tavazzi L; Yu CM;
    J Card Fail; 2009 Jun; 15(5):394-400. PubMed ID: 19477399
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A critical link between heart failure self-care and intrathoracic impedance.
    Rathman LD; Lee CS; Sarkar S; Small RS
    J Cardiovasc Nurs; 2011; 26(4):E20-6. PubMed ID: 21076309
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Continuous monitoring of intrathoracic impedance and right ventricular pressures in patients with heart failure.
    Vanderheyden M; Houben R; Verstreken S; Ståhlberg M; Reiters P; Kessels R; Braunschweig F
    Circ Heart Fail; 2010 May; 3(3):370-7. PubMed ID: 20197559
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Device monitoring of heart failure in cardiac resynchronization therapy device recipients: a single-center experience with a novel multivector impedance monitoring system.
    Forleo GB; Panattoni G; Schirripa V; Papavasileiou LP; Della Rocca DG; Politano A; Ticconi F; Biscione C; Sergi D; Di Molfetta A; Santini L; Capria A; Romeo F
    J Cardiovasc Med (Hagerstown); 2013 Oct; 14(10):726-32. PubMed ID: 23996011
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Intrathoracic impedance and ultrasound lung comets in heart failure deterioration monitoring.
    Maines M; Catanzariti D; Angheben C; Valsecchi S; Comisso J; Vergara G
    Pacing Clin Electrophysiol; 2011 Aug; 34(8):968-74. PubMed ID: 21477028
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Relationship of paroxysmal atrial tachyarrhythmias to volume overload: assessment by implanted transpulmonary impedance monitoring.
    Jhanjee R; Templeton GA; Sattiraju S; Nguyen J; Sakaguchi S; Lu F; Ermis C; Milstein S; Van Heel L; Lurie KG; Benditt DG
    Circ Arrhythm Electrophysiol; 2009 Oct; 2(5):488-94. PubMed ID: 19843916
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Intrathoracic impedance vs daily weight monitoring for predicting worsening heart failure events: results of the Fluid Accumulation Status Trial (FAST).
    Abraham WT; Compton S; Haas G; Foreman B; Canby RC; Fishel R; McRae S; Toledo GB; Sarkar S; Hettrick DA;
    Congest Heart Fail; 2011; 17(2):51-5. PubMed ID: 21449992
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.