These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 24654598)

  • 1. An evaluation of local thermal analysis of polymers on the sub-micrometer scale using heated scanning probe microscopy cantilevers.
    Fischinger TJ; Laher M; Hild S
    J Phys Chem B; 2014 May; 118(20):5570-6. PubMed ID: 24654598
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Thermoelectric voltage at a nanometer-scale heated tip point contact.
    Fletcher PC; Lee B; King WP
    Nanotechnology; 2012 Jan; 23(3):035401. PubMed ID: 22173299
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measuring material softening with nanoscale spatial resolution using heated silicon probes.
    Nelson BA; King WP
    Rev Sci Instrum; 2007 Feb; 78(2):023702. PubMed ID: 17578112
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Nanoscale thermal AFM of polymers: transient heat flow effects.
    Duvigneau J; Schönherr H; Vancso GJ
    ACS Nano; 2010 Nov; 4(11):6932-40. PubMed ID: 20979371
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An investigation of heat transfer between a microcantilever and a substrate for improved thermal topography imaging.
    Somnath S; King WP
    Nanotechnology; 2014 Sep; 25(36):365501. PubMed ID: 25122588
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Study of thermal and acoustic noise interferences in low stiffness atomic force microscope cantilevers and characterization of their dynamic properties.
    Boudaoud M; Haddab Y; Le Gorrec Y; Lutz P
    Rev Sci Instrum; 2012 Jan; 83(1):013704. PubMed ID: 22299959
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Noncontact sub-10 nm temperature measurement in near-field laser heating.
    Yue Y; Chen X; Wang X
    ACS Nano; 2011 Jun; 5(6):4466-75. PubMed ID: 21557563
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Topography imaging with a heated atomic force microscope cantilever in tapping mode.
    Park K; Lee J; Zhang ZM; King WP
    Rev Sci Instrum; 2007 Apr; 78(4):043709. PubMed ID: 17477672
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The development of heated tip force-distance measurements as a novel approach to site-specific characterization of pharmaceutical materials.
    Harding L; Reading M; Craig DQ
    J Pharm Sci; 2008 Jul; 97(7):2768-79. PubMed ID: 17549768
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Probing the temperature dependence of the mechanical properties of polymers at the nanoscale with band excitation thermal scanning probe microscopy.
    Nikiforov MP; Jesse S; Morozovska AN; Eliseev EA; Germinario LT; Kalinin SV
    Nanotechnology; 2009 Sep; 20(39):395709. PubMed ID: 19726838
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Error in dynamic spring constant calibration of atomic force microscope probes due to nonuniform cantilevers.
    Frentrup H; Allen MS
    Nanotechnology; 2011 Jul; 22(29):295703. PubMed ID: 21673383
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Elevated temperature, nano-mechanical testing in situ in the scanning electron microscope.
    Wheeler JM; Michler J
    Rev Sci Instrum; 2013 Apr; 84(4):045103. PubMed ID: 23635228
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Nanoscale thermal-mechanical probe determination of 'softening transitions' in thin polymer films.
    Zhou J; Berry B; Douglas JF; Karim A; Snyder CR; Soles C
    Nanotechnology; 2008 Dec; 19(49):495703. PubMed ID: 21730683
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Quantitative temperature distribution measurements by non-contact scanning thermal microscopy using Wollaston probes under ambient conditions.
    Zhang Y; Zhu W; Han L; Borca-Tasciuc T
    Rev Sci Instrum; 2020 Jan; 91(1):014901. PubMed ID: 32012522
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ultrananocrystalline diamond tip integrated onto a heated atomic force microscope cantilever.
    Kim HJ; Moldovan N; Felts JR; Somnath S; Dai Z; Jacobs TD; Carpick RW; Carlisle JA; King WP
    Nanotechnology; 2012 Dec; 23(49):495302. PubMed ID: 23149947
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Enabling low-noise null-point scanning thermal microscopy by the optimization of scanning thermal microscope probe through a rigorous theory of quantitative measurement.
    Hwang G; Chung J; Kwon O
    Rev Sci Instrum; 2014 Nov; 85(11):114901. PubMed ID: 25430136
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Calibration of the spring constant of cantilevers of arbitrary shape using the phase signal in an atomic force microscope.
    Rawlings C; Durkan C
    Nanotechnology; 2012 Dec; 23(48):485708. PubMed ID: 23137943
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accurate measurement of Atomic Force Microscope cantilever deflection excluding tip-surface contact with application to force calibration.
    Slattery AD; Blanch AJ; Quinton JS; Gibson CT
    Ultramicroscopy; 2013 Aug; 131():46-55. PubMed ID: 23685172
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Glass transitions in nanoscale heated volumes of thin polystyrene films.
    Li AG; Burggraf LW
    Rev Sci Instrum; 2010 Dec; 81(12):123707. PubMed ID: 21198032
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Nanometer-scale heat-conductivity measurements on biological samples.
    Haeberle W; Pantea M; Hoerber JK
    Ultramicroscopy; 2006; 106(8-9):678-86. PubMed ID: 16730408
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.