BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

544 related articles for article (PubMed ID: 24655704)

  • 1. Acute echocardiographic optimization of multiple stimulation configurations of cardiac resynchronization therapy through quadripolar left ventricular pacing: a tailored approach.
    Calò L; Martino A; de Ruvo E; Minati M; Fratini S; Rebecchi M; Lanzillo C; Fagagnini A; Borrelli A; De Luca L; Sciarra L
    Am Heart J; 2014 Apr; 167(4):546-54. PubMed ID: 24655704
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effects of resynchronization therapy on cardiac function in pacemaker patients "upgraded" to biventricular devices.
    Horwich T; Foster E; De Marco T; Tseng Z; Saxon L
    J Cardiovasc Electrophysiol; 2004 Nov; 15(11):1284-9. PubMed ID: 15574179
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Application and efficacy of the adjustment on left ventricular electrical delay and the distance between right and left ventricular pacing polar in optimizing the left ventricular pacing polar].
    Yan XL; Liang YC; Yu HB; Xu BG; Gao Y; Liu R; Xu GQ; Wu M
    Zhonghua Xin Xue Guan Bing Za Zhi; 2020 Aug; 48(8):669-674. PubMed ID: 32847323
    [No Abstract]   [Full Text] [Related]  

  • 4. Multipoint left ventricular pacing in a single coronary sinus branch improves mid-term echocardiographic and clinical response to cardiac resynchronization therapy.
    Pappone C; Ćalović Ž; Vicedomini G; Cuko A; McSpadden LC; Ryu K; Romano E; Baldi M; Saviano M; Pappone A; Ciaccio C; Giannelli L; Ionescu B; Petretta A; Vitale R; Fundaliotis A; Tavazzi L; Santinelli V
    J Cardiovasc Electrophysiol; 2015 Jan; 26(1):58-63. PubMed ID: 25109276
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Acute changes in electromechanical parameters during different pacing configurations using a quadripolar left ventricular lead.
    Valzania C; Eriksson MJ; Biffi M; Boriani G; Gadler F
    J Interv Card Electrophysiol; 2013 Oct; 38(1):61-9. PubMed ID: 23818121
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cardiac resynchronization therapy (CRT) with right ventricular sense triggered left ventricular pacing benefits for the hemodynamics compared with standard CRT for chronic congestive heart failure: A cross-over study.
    Pu LJ; Wang Y; Zhao L; Luo ZL; Hua BT; Han MH; Li SM; Yang J; Li L; Peng YZ; Guo T
    Cardiol J; 2015; 22(1):80-6. PubMed ID: 25179313
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A randomized double-blind comparison of biventricular versus left ventricular stimulation for cardiac resynchronization therapy: the Biventricular versus Left Univentricular Pacing with ICD Back-up in Heart Failure Patients (B-LEFT HF) trial.
    Boriani G; Kranig W; Donal E; Calo L; Casella M; Delarche N; Lozano IF; Ansalone G; Biffi M; Boulogne E; Leclercq C;
    Am Heart J; 2010 Jun; 159(6):1052-1058.e1. PubMed ID: 20569719
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Multipoint left ventricular pacing improves acute hemodynamic response assessed with pressure-volume loops in cardiac resynchronization therapy patients.
    Pappone C; Ćalović Ž; Vicedomini G; Cuko A; McSpadden LC; Ryu K; Romano E; Saviano M; Baldi M; Pappone A; Ciaccio C; Giannelli L; Ionescu B; Petretta A; Vitale R; Fundaliotis A; Tavazzi L; Santinelli V
    Heart Rhythm; 2014 Mar; 11(3):394-401. PubMed ID: 24291411
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of cardiac resynchronization therapy on left ventricular size and function in chronic heart failure.
    St John Sutton MG; Plappert T; Abraham WT; Smith AL; DeLurgio DB; Leon AR; Loh E; Kocovic DZ; Fisher WG; Ellestad M; Messenger J; Kruger K; Hilpisch KE; Hill MR;
    Circulation; 2003 Apr; 107(15):1985-90. PubMed ID: 12668512
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Improvement in hemodynamic response using a quadripolar LV lead.
    Cabrera Bueno F; Alzueta Rodríguez J; Olagüe de Ros J; Fernández-Lozano I; García Guerrero JJ; de la Concha JF; Hernández Madrid A; Tolosana Viu JM; Osca Asensi J; Barrera Cordero A; Llorente Hernangómez E
    Pacing Clin Electrophysiol; 2013 Aug; 36(8):963-9. PubMed ID: 23692289
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Left ventricular resynchronization is mandatory for response to cardiac resynchronization therapy: analysis in patients with echocardiographic evidence of left ventricular dyssynchrony at baseline.
    Bleeker GB; Mollema SA; Holman ER; Van de Veire N; Ypenburg C; Boersma E; van der Wall EE; Schalij MJ; Bax JJ
    Circulation; 2007 Sep; 116(13):1440-8. PubMed ID: 17785624
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Outcome of Patients Treated by Cardiac Resynchronization Therapy Using a Quadripolar Left Ventricular Lead.
    Bencardino G; Di Monaco A; Russo E; Colizzi C; Perna F; Pelargonio G; Narducci ML; Gabrielli FA; Lanza GA; Rebuzzi AG; Crea F
    Circ J; 2016; 80(3):613-8. PubMed ID: 26821688
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optimization of left ventricular pacing site plus multipoint pacing improves remodeling and clinical response to cardiac resynchronization therapy at 1 year.
    Zanon F; Marcantoni L; Baracca E; Pastore G; Lanza D; Fraccaro C; Picariello C; Conte L; Aggio S; Roncon L; Pacetta D; Badie N; Noventa F; Prinzen FW
    Heart Rhythm; 2016 Aug; 13(8):1644-51. PubMed ID: 27450156
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Tailored echocardiographic interventricular delay programming further optimizes left ventricular performance after cardiac resynchronization therapy.
    Vanderheyden M; De Backer T; Rivero-Ayerza M; Geelen P; Bartunek J; Verstreken S; De Zutter M; Goethals M
    Heart Rhythm; 2005 Oct; 2(10):1066-72. PubMed ID: 16188583
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Can We Use the Intrinsic Left Ventricular Delay (QLV) to Optimize the Pacing Configuration for Cardiac Resynchronization Therapy With a Quadripolar Left Ventricular Lead?
    van Everdingen WM; Zweerink A; Cramer MJ; Doevendans PA; Nguyên UC; van Rossum AC; Prinzen FW; Vernooy K; Allaart CP; Meine M
    Circ Arrhythm Electrophysiol; 2018 Mar; 11(3):e005912. PubMed ID: 29874169
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Time course of left ventricular volumes in severe congestive heart failure patients treated by optimized AV sequential left ventricular pacing alone--a 3-dimensional echocardiographic study.
    Butter C; Wellnhofer E; Seifert M; Schlegl M; Hoersch W; Goehring A; Fleck E
    Am Heart J; 2006 Jan; 151(1):115-23. PubMed ID: 16368302
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improvement in acute contractility and hemodynamics with multipoint pacing via a left ventricular quadripolar pacing lead.
    Rinaldi CA; Leclercq C; Kranig W; Kacet S; Betts T; Bordachar P; Gutleben KJ; Shetty A; Donal E; Keel A; Ryu K; Farazi TG; Simon M; Naqvi TZ
    J Interv Card Electrophysiol; 2014 Jun; 40(1):75-80. PubMed ID: 24626999
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Impact of Left Ventricular vs Biventricular Pacing on Reverse Remodelling: Insights From the Evaluation of Resynchronization Therapy for Heart Failure (EARTH) Trial.
    Skaf S; Thibault B; Khairy P; O'Meara E; Fortier A; Vakulenko HV; Pitre C; White M; Ducharme A;
    Can J Cardiol; 2017 Oct; 33(10):1274-1282. PubMed ID: 28941607
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Left ventricular lead electrical delay predicts response to cardiac resynchronization therapy.
    Singh JP; Fan D; Heist EK; Alabiad CR; Taub C; Reddy V; Mansour M; Picard MH; Ruskin JN; Mela T
    Heart Rhythm; 2006 Nov; 3(11):1285-92. PubMed ID: 17074633
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Long-term reverse remodeling by cardiac resynchronization therapy with MultiPoint Pacing: A feasibility study of noninvasive hemodynamics-guided device programming.
    Lercher P; Lunati M; Rordorf R; Landolina M; Badie N; Qu F; Casset C; Ryu K; Ghio S; Singh JP; Leclercq C
    Heart Rhythm; 2018 Dec; 15(12):1766-1774. PubMed ID: 29940305
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 28.