These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Compression feedback devices over estimate chest compression depth when performed on a bed. Perkins GD; Kocierz L; Smith SC; McCulloch RA; Davies RP Resuscitation; 2009 Jan; 80(1):79-82. PubMed ID: 18952361 [TBL] [Abstract][Full Text] [Related]
5. A novel method to decrease mattress compression during CPR using a mattress compression cover and a vacuum pump. Oh J; Chee Y; Song Y; Lim T; Kang H; Cho Y Resuscitation; 2013 Jul; 84(7):987-91. PubMed ID: 23318913 [TBL] [Abstract][Full Text] [Related]
6. Use of backboard and deflation improve quality of chest compression when cardiopulmonary resuscitation is performed on a typical air inflated mattress configuration. Oh J; Kang H; Chee Y; Lim T; Song Y; Cho Y; Je S J Korean Med Sci; 2013 Feb; 28(2):315-9. PubMed ID: 23399985 [TBL] [Abstract][Full Text] [Related]
7. Quality of cardiopulmonary resuscitation on manikins: on the floor and in the bed. Jäntti H; Silfvast T; Turpeinen A; Kiviniemi V; Uusaro A Acta Anaesthesiol Scand; 2009 Oct; 53(9):1131-7. PubMed ID: 19388894 [TBL] [Abstract][Full Text] [Related]
8. Proper target depth of an accelerometer-based feedback device during CPR performed on a hospital bed: a randomized simulation study. Lee S; Oh J; Kang H; Lim T; Kim W; Chee Y; Song Y; Ahn C; Cho JH Am J Emerg Med; 2015 Oct; 33(10):1425-9. PubMed ID: 26298053 [TBL] [Abstract][Full Text] [Related]
9. The quality of manual chest compressions during transport--effect of the mattress assessed by dual accelerometers. Hellevuo H; Sainio M; Huhtala H; Olkkola KT; Tenhunen J; Hoppu S Acta Anaesthesiol Scand; 2014 Mar; 58(3):323-8. PubMed ID: 24372080 [TBL] [Abstract][Full Text] [Related]
10. The use of dual accelerometers improves measurement of chest compression depth. Oh J; Song Y; Kang B; Kang H; Lim T; Suh Y; Chee Y Resuscitation; 2012 Apr; 83(4):500-4. PubMed ID: 22001002 [TBL] [Abstract][Full Text] [Related]
11. A flexible pressure sensor could correctly measure the depth of chest compression on a mattress. Minami K; Kokubo Y; Maeda I; Hibino S Am J Emerg Med; 2016 May; 34(5):899-902. PubMed ID: 26979259 [TBL] [Abstract][Full Text] [Related]
12. Backboards are important when chest compressions are provided on a soft mattress. Nishisaki A; Maltese MR; Niles DE; Sutton RM; Urbano J; Berg RA; Nadkarni VM Resuscitation; 2012 Aug; 83(8):1013-20. PubMed ID: 22310727 [TBL] [Abstract][Full Text] [Related]
13. The impact of compliant surfaces on in-hospital chest compressions: effects of common mattresses and a backboard. Noordergraaf GJ; Paulussen IW; Venema A; van Berkom PF; Woerlee PH; Scheffer GJ; Noordergraaf A Resuscitation; 2009 May; 80(5):546-52. PubMed ID: 19409300 [TBL] [Abstract][Full Text] [Related]
14. Training a Chest Compression of 6-7 cm Depth for High Quality Cardiopulmonary Resuscitation in Hospital Setting: A Randomised Controlled Trial. Oh J; Lim TH; Cho Y; Kang H; Kim W; Chee Y; Song Y; Kim IY; Lee J Yonsei Med J; 2016 Mar; 57(2):505-11. PubMed ID: 26847307 [TBL] [Abstract][Full Text] [Related]
15. Effect of Emergency Department Mattress Compressibility on Chest Compression Depth Using a Standardized Cardiopulmonary Resuscitation Board, a Slider Transfer Board, and a Flat Spine Board: A Simulation-Based Study. Cheng A; Belanger C; Wan B; Davidson J; Lin Y Simul Healthc; 2017 Dec; 12(6):364-369. PubMed ID: 28697056 [TBL] [Abstract][Full Text] [Related]
16. The impact of backboard size and orientation on sternum-to-spine compression depth and compression stiffness in a manikin study of CPR using two mattress types. Cloete G; Dellimore KH; Scheffer C; Smuts MS; Wallis LA Resuscitation; 2011 Aug; 82(8):1064-70. PubMed ID: 21601344 [TBL] [Abstract][Full Text] [Related]
17. Reducing the impact of intensive care unit mattress compressibility during CPR: a simulation-based study. Lin Y; Wan B; Belanger C; Hecker K; Gilfoyle E; Davidson J; Cheng A Adv Simul (Lond); 2017; 2():22. PubMed ID: 29450023 [TBL] [Abstract][Full Text] [Related]
18. Effects of a backboard, bed height, and operator position on compression depth during simulated resuscitation. Perkins GD; Smith CM; Augre C; Allan M; Rogers H; Stephenson B; Thickett DR Intensive Care Med; 2006 Oct; 32(10):1632-5. PubMed ID: 16826385 [TBL] [Abstract][Full Text] [Related]
19. The Impact of Backboard Placement on Chest Compression Quality: A Mannequin Study. Sanri E; Karacabey S Prehosp Disaster Med; 2019 Apr; 34(2):182-187. PubMed ID: 30981288 [TBL] [Abstract][Full Text] [Related]
20. Incomplete chest wall decompression: a clinical evaluation of CPR performance by EMS personnel and assessment of alternative manual chest compression-decompression techniques. Aufderheide TP; Pirrallo RG; Yannopoulos D; Klein JP; von Briesen C; Sparks CW; Deja KA; Conrad CJ; Kitscha DJ; Provo TA; Lurie KG Resuscitation; 2005 Mar; 64(3):353-62. PubMed ID: 15733766 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]