170 related articles for article (PubMed ID: 24659201)
1. Optimal glenoid component inclination in reverse shoulder arthroplasty. How to improve implant stability.
Randelli P; Randelli F; Arrigoni P; Ragone V; D'Ambrosi R; Masuzzo P; Cabitza P; Banfi G
Musculoskelet Surg; 2014 Apr; 98 Suppl 1():15-8. PubMed ID: 24659201
[TBL] [Abstract][Full Text] [Related]
2. Inferior tilt of the glenoid leads to medialization and increases impingement on the scapular neck in reverse shoulder arthroplasty.
Patel M; Martin JR; Campbell DH; Fernandes RR; Amini MH
J Shoulder Elbow Surg; 2021 Jun; 30(6):1273-1281. PubMed ID: 33069903
[TBL] [Abstract][Full Text] [Related]
3. Bony increased-offset-reverse shoulder arthroplasty: 5 to 10 years' follow-up.
Boileau P; Morin-Salvo N; Bessière C; Chelli M; Gauci MO; Lemmex DB
J Shoulder Elbow Surg; 2020 Oct; 29(10):2111-2122. PubMed ID: 32505414
[TBL] [Abstract][Full Text] [Related]
4. Evaluation of the role of glenosphere design and humeral component retroversion in avoiding scapular notching during reverse shoulder arthroplasty.
Berhouet J; Garaud P; Favard L
J Shoulder Elbow Surg; 2014 Feb; 23(2):151-8. PubMed ID: 23850310
[TBL] [Abstract][Full Text] [Related]
5. Biomechanical Characteristics of Glenosphere Orientation Based on Tilting Angle and Overhang Changes in Reverse Shoulder Arthroplasty.
Lee JH; Kim SH; Kim JH; Baek G; Nakla A; McGarry M; Lee TQ; Shin SJ
Clin Orthop Surg; 2024 Apr; 16(2):303-312. PubMed ID: 38562639
[TBL] [Abstract][Full Text] [Related]
6. A new method to evaluate the influence of the glenosphere positioning on stability and range of motion of a reverse shoulder prosthesis.
Ingrassia T; Nigrelli V; Ricotta V; Nalbone L; D'Arienzo A; D'Arienzo M; Porcellini G
Injury; 2019 Jul; 50 Suppl 2():S12-S17. PubMed ID: 30745125
[TBL] [Abstract][Full Text] [Related]
7. Influence of glenoid component design and humeral component retroversion on internal and external rotation in reverse shoulder arthroplasty: a cadaver study.
Berhouet J; Garaud P; Favard L
Orthop Traumatol Surg Res; 2013 Dec; 99(8):887-94. PubMed ID: 24211248
[TBL] [Abstract][Full Text] [Related]
8. The influence of humeral head inclination in reverse total shoulder arthroplasty: a systematic review.
Erickson BJ; Frank RM; Harris JD; Mall N; Romeo AA
J Shoulder Elbow Surg; 2015 Jun; 24(6):988-93. PubMed ID: 25725965
[TBL] [Abstract][Full Text] [Related]
9. Effect of baseplate positioning on fixation of reverse total shoulder arthroplasty.
Zhang M; Junaid S; Gregory T; Hansen U; Cheng CK
Clin Biomech (Bristol, Avon); 2019 Feb; 62():15-22. PubMed ID: 30658155
[TBL] [Abstract][Full Text] [Related]
10. The effect of glenosphere diameter in reverse shoulder arthroplasty on muscle force, joint load, and range of motion.
Langohr GD; Giles JW; Athwal GS; Johnson JA
J Shoulder Elbow Surg; 2015 Jun; 24(6):972-9. PubMed ID: 25547853
[TBL] [Abstract][Full Text] [Related]
11. Superior Baseplate Inclination Is Associated With Instability After Reverse Total Shoulder Arthroplasty.
Tashjian RZ; Martin BI; Ricketts CA; Henninger HB; Granger EK; Chalmers PN
Clin Orthop Relat Res; 2018 Aug; 476(8):1622-1629. PubMed ID: 29781910
[TBL] [Abstract][Full Text] [Related]
12. The reverse shoulder arthroplasty angle: a new measurement of glenoid inclination for reverse shoulder arthroplasty.
Boileau P; Gauci MO; Wagner ER; Clowez G; Chaoui J; Chelli M; Walch G
J Shoulder Elbow Surg; 2019 Jul; 28(7):1281-1290. PubMed ID: 30935825
[TBL] [Abstract][Full Text] [Related]
13. Inferior tilt fixation of the glenoid component in reverse total shoulder arthroplasty: A biomechanical study.
Chae SW; Lee J; Han SH; Kim SY
Orthop Traumatol Surg Res; 2015 Jun; 101(4):421-5. PubMed ID: 25907513
[TBL] [Abstract][Full Text] [Related]
14. Reverse total shoulder arthroplasty: radiological and clinical result using an eccentric glenosphere.
De Biase CF; Delcogliano M; Borroni M; Castagna A
Musculoskelet Surg; 2012 May; 96 Suppl 1():S27-34. PubMed ID: 22528848
[TBL] [Abstract][Full Text] [Related]
15. Range of impingement-free abduction and adduction deficit after reverse shoulder arthroplasty. Hierarchy of surgical and implant-design-related factors.
Gutiérrez S; Comiskey CA; Luo ZP; Pupello DR; Frankle MA
J Bone Joint Surg Am; 2008 Dec; 90(12):2606-15. PubMed ID: 19047705
[TBL] [Abstract][Full Text] [Related]
16. Comparison of Clinical and Radiological Results according to Glenosphere Position in Reverse Total Shoulder Arthroplasty: A Short-term Follow-up Study.
Choi CH; Kim SG; Lee JJ; Kwack BH
Clin Orthop Surg; 2017 Mar; 9(1):83-90. PubMed ID: 28261432
[TBL] [Abstract][Full Text] [Related]
17. Influence of Glenosphere and baseplate parameters on Glenoid bone strains in reverse shoulder Arthroplasty.
Pauzenberger L; Dwyer C; Obopilwe E; Nowak MD; Cote M; Romeo AA; Mazzocca AD; Dyrna F
BMC Musculoskelet Disord; 2019 Dec; 20(1):587. PubMed ID: 31805924
[TBL] [Abstract][Full Text] [Related]
18. Glenosphere design affects range of movement and risk of friction-type scapular impingement in reverse shoulder arthroplasty.
Werner BS; Chaoui J; Walch G
Bone Joint J; 2018 Sep; 100-B(9):1182-1186. PubMed ID: 30168761
[TBL] [Abstract][Full Text] [Related]
19. Effects of glenosphere positioning on impingement-free internal and external rotation after reverse total shoulder arthroplasty.
Li X; Knutson Z; Choi D; Lobatto D; Lipman J; Craig EV; Warren RF; Gulotta LV
J Shoulder Elbow Surg; 2013 Jun; 22(6):807-13. PubMed ID: 22999850
[TBL] [Abstract][Full Text] [Related]
20. Anatomic factors influencing the anterior stability of reverse total shoulder arthroplasty.
Pastor MF; Smith T; Ellwein A; Hagenah J; Hurschler C; Ferle M
J Shoulder Elbow Surg; 2020 Dec; 29(12):2619-2625. PubMed ID: 32532522
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]