These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

176 related articles for article (PubMed ID: 24660749)

  • 21. A new cochlear implant electrode with a "cork"-type stopper for inner ear malformations.
    Sennaroğlu L; Atay G; Bajin MD
    Auris Nasus Larynx; 2014 Aug; 41(4):331-6. PubMed ID: 24560093
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Simple method to control a cerebrospinal fluid gusher during cochlear implant surgery.
    Marks HW
    Otol Neurotol; 2004 Jul; 25(4):483-4. PubMed ID: 15241226
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Influence of an intraoperative perilymph gusher on cochlear implant performance in children with labyrinthine malformations.
    Adunka OF; Teagle HF; Zdanski CJ; Buchman CA
    Otol Neurotol; 2012 Dec; 33(9):1489-96. PubMed ID: 22996156
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Management of surgical difficulties during cochlear implant with inner ear anomalies.
    Aldhafeeri AM; Alsanosi AA
    Int J Pediatr Otorhinolaryngol; 2017 Jan; 92():45-49. PubMed ID: 28012532
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Prediction of Intraoperative CSF Gusher and Postoperative Facial Nerve Stimulation in Patients With Cochleovestibular Malformations Undergoing Cochlear Implantation Surgery.
    Kamogashira T; Iwasaki S; Kashio A; Kakigi A; Karino S; Matsumoto Y; Yamasoba T
    Otol Neurotol; 2017 Jul; 38(6):e114-e119. PubMed ID: 28475547
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The unilateral stapes gusher.
    Rebol J
    Wien Klin Wochenschr; 2004; 116 Suppl 2():90-2. PubMed ID: 15506322
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Cochlear implant in patients with congenital malformation of inner ear].
    Han DY; Wu WM; Xi X; Huang DL; Yang WY
    Zhonghua Er Bi Yan Hou Ke Za Zhi; 2004 Feb; 39(2):85-8. PubMed ID: 15195589
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Cochlear implants in children with congenital inner ear malformations.
    Luntz M; Balkany T; Hodges AV; Telischi FF
    Arch Otolaryngol Head Neck Surg; 1997 Sep; 123(9):974-7. PubMed ID: 9305249
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Cochlear implantation in incomplete partition type I.
    Eftekharian A; Eftekharian K; Mokari N; Fazel M
    Eur Arch Otorhinolaryngol; 2019 Oct; 276(10):2763-2768. PubMed ID: 31256245
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Implantation of the common cavity malformation may prevent meningitis.
    Roman BR; Coelho DH; Roland JT
    Cochlear Implants Int; 2013 Jan; 14(1):56-60. PubMed ID: 22333042
    [TBL] [Abstract][Full Text] [Related]  

  • 31. FORM24 electrode array and perioperative cerebrospinal fluid leakage in cochlear implant recipients with cochleovestibular malformations.
    Halawani R; Alzhrani F; Almuhawas F; Hagr AA
    Ann Saudi Med; 2020; 40(6):477-481. PubMed ID: 33307737
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Cochlear implant for malformations of the inner ear].
    Aschendorff A; Laszig R; Maier W; Beck R; Schild C; Birkenhäger R; Wesarg T; Kröger S; Arndt S
    HNO; 2009 Jun; 57(6):533-41. PubMed ID: 19452138
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Cochlear implantation in children with inner ear malformation and postoperative performance].
    Ishida K; Makoto S; Iida M; Takahashi M; Naito A; Kitano Y; Koga K
    Nihon Jibiinkoka Gakkai Kaiho; 1999 Dec; 102(12):1300-10. PubMed ID: 10655719
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Incidence and management of gusher in cochlear implantation.
    Soda-Merhy A; Olguín-Vega GJ; Cristerna-Sánchez L; Martín-Biasotti F
    Cir Cir; 2019; 87(6):650-655. PubMed ID: 31631178
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Why did we encounter gusher in a stapes surgery case? Was it enlarged medial aperture of the cochlear aqueduct?
    Satar B; Genc H; Meral SC
    Surg Radiol Anat; 2021 Feb; 43(2):225-229. PubMed ID: 33111218
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Audiological performance after cochlear implantation in children with inner ear malformations.
    Arnoldner C; Baumgartner WD; Gstoettner W; Egelierler B; Czerny C; Steiner E; Hamzavi J
    Int J Pediatr Otorhinolaryngol; 2004 Apr; 68(4):457-67. PubMed ID: 15013614
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Intraoperative seizure and cerebrospinal fluid leak during adult cochlear implant surgery.
    Musser AB; Golub JS; Samy RN; Phero JC
    Cochlear Implants Int; 2016; 17(2):116-9. PubMed ID: 26843205
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Surgical considerations in cochlear implantation in children and adults: a review of 342 cases in Vienna.
    Arnoldner C; Baumgartner WD; Gstoettner W; Hamzavi J
    Acta Otolaryngol; 2005 Mar; 125(3):228-34. PubMed ID: 15966689
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Surgical techniques for cochlear implantation of the malformed inner ear.
    Luntz M; Balkany T; Telischi FF; Hodges AV
    Am J Otol; 1997 Nov; 18(6 Suppl):S66. PubMed ID: 9391602
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Enlarged cochlear aqueducts: a potential route for CSF gushers in patients with enlarged vestibular aqueducts.
    Kim BG; Sim NS; Kim SH; Kim UK; Kim S; Choi JY
    Otol Neurotol; 2013 Dec; 34(9):1660-5. PubMed ID: 24232063
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.