These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

414 related articles for article (PubMed ID: 24662096)

  • 1. Monte Carlo comparison of superficial dose between flattening filter free and flattened beams.
    Javedan K; Feygelman V; Zhang RR; Moros EG; Correa CR; Trotti A; Li W; Zhang GG
    Phys Med; 2014 Jun; 30(4):503-8. PubMed ID: 24662096
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Superficial and peripheral dose in compensator-based FFF beam IMRT.
    Zhang DG; Feygelman V; Moros EG; Latifi K; Hoffe S; Frakes J; Zhang GG
    J Appl Clin Med Phys; 2017 Jan; 18(1):151-156. PubMed ID: 28291940
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Monte Carlo study of in-field and out-of-field dose distributions from a linear accelerator operating with and without a flattening-filter.
    Almberg SS; Frengen J; Lindmo T
    Med Phys; 2012 Aug; 39(8):5194-203. PubMed ID: 22894444
    [TBL] [Abstract][Full Text] [Related]  

  • 4. SU-E-T-479: Skin Dose from Flattening Filter Free Beams: A Monte Carlo Investigation.
    Zhang G; Javedan K; Moros E; Latifi K; Feygelman V; Moffitt HL
    Med Phys; 2012 Jun; 39(6Part17):3815. PubMed ID: 28517489
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A comprehensive Study of the Out of Field Non Target Dose Associated with 6 and 10 MV Flattened and Flattening Filter Free X Ray Beam in a True Beam Linear Accelerator.
    Athiyaman H; Anbu G; Mayilvaganan A; Chougule A; Sharma N; Kumar HS
    Asian Pac J Cancer Prev; 2024 May; 25(5):1529-1538. PubMed ID: 38809624
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Flattening filter free in intensity-modulated radiotherapy (IMRT) - Theoretical modeling with delivery efficiency analysis.
    Ma C; Chen M; Long T; Parsons D; Gu X; Jiang S; Hou Q; Lu W
    Med Phys; 2019 Jan; 46(1):34-44. PubMed ID: 30371944
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Beam characteristics of energy-matched flattening filter free beams.
    Paynter D; Weston SJ; Cosgrove VP; Evans JA; Thwaites DI
    Med Phys; 2014 May; 41(5):052103. PubMed ID: 24784392
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Characteristics of flattening filter free beams at low monitor unit settings.
    Akino Y; Ota S; Inoue S; Mizuno H; Sumida I; Yoshioka Y; Isohashi F; Ogawa K
    Med Phys; 2013 Nov; 40(11):112101. PubMed ID: 24320454
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monte Carlo simulation of TrueBeam flattening-filter-free beams using varian phase-space files: comparison with experimental data.
    Belosi MF; Rodriguez M; Fogliata A; Cozzi L; Sempau J; Clivio A; Nicolini G; Vanetti E; Krauss H; Khamphan C; Fenoglietto P; Puxeu J; Fedele D; Mancosu P; Brualla L
    Med Phys; 2014 May; 41(5):051707. PubMed ID: 24784373
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Flattening filter free vs flattened beams for breast irradiation.
    Spruijt KH; Dahele M; Cuijpers JP; Jeulink M; Rietveld D; Slotman BJ; Verbakel WF
    Int J Radiat Oncol Biol Phys; 2013 Feb; 85(2):506-13. PubMed ID: 22672750
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Moving GPU-OpenCL-based Monte Carlo dose calculation toward clinical use: Automatic beam commissioning and source sampling for treatment plan dose calculation.
    Tian Z; Li Y; Hassan-Rezaeian N; Jiang SB; Jia X
    J Appl Clin Med Phys; 2017 Mar; 18(2):69-84. PubMed ID: 28300376
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Surface dose investigation of the flattening filter-free photon beams.
    Wang Y; Khan MK; Ting JY; Easterling SB
    Int J Radiat Oncol Biol Phys; 2012 Jun; 83(2):e281-5. PubMed ID: 22414287
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Combining tissue-phantom ratios to provide a beam-quality specifier for flattening filter free photon beams.
    Dalaryd M; Knöös T; Ceberg C
    Med Phys; 2014 Nov; 41(11):111716. PubMed ID: 25370630
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of 10 MV and Flattening-Filter-Free Beams on Peripheral Dose in a Cohort of Pediatric Patients.
    Ben Bouchta Y; Goddard K; Petric MP; Bergman AM
    Int J Radiat Oncol Biol Phys; 2018 Dec; 102(5):1560-1568. PubMed ID: 30071294
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Validation of a virtual source model for Monte Carlo dose calculations of a flattening filter free linac.
    Cashmore J; Golubev S; Dumont JL; Sikora M; Alber M; Ramtohul M
    Med Phys; 2012 Jun; 39(6):3262-9. PubMed ID: 22755709
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A comparison of phantom scatter from flattened and flattening filter free high-energy photon beams.
    Richmond N; Allen V; Daniel J; Dacey R; Walker C
    Med Dosim; 2015; 40(1):58-63. PubMed ID: 25454113
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Clinically relevant investigation of flattening filter-free skin dose.
    Guy CL; Karki K; Sharma M; Kim S
    J Appl Clin Med Phys; 2016 Nov; 17(6):140-148. PubMed ID: 27929489
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An analytical formalism to calculate phantom scatter factors for flattening filter free (FFF) mode photon beams.
    Chung H; Prado KL; Yi BY
    Phys Med Biol; 2014 Feb; 59(4):951-60. PubMed ID: 24503449
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dose evaluation of Grid Therapy using a 6 MV flattening filter-free (FFF) photon beam: A Monte Carlo study.
    Martínez-Rovira I; Puxeu-Vaqué J; Prezado Y
    Med Phys; 2017 Oct; 44(10):5378-5383. PubMed ID: 28736809
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Flattening filter free beams in SBRT and IMRT: dosimetric assessment of peripheral doses.
    Kragl G; Baier F; Lutz S; Albrich D; Dalaryd M; Kroupa B; Wiezorek T; Knöös T; Georg D
    Z Med Phys; 2011 May; 21(2):91-101. PubMed ID: 20888199
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 21.