These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 24664245)

  • 21. Anatomically correct visualization of the human upper airway using a high-speed long range optical coherence tomography system with an integrated positioning sensor.
    Jing JC; Chou L; Su E; Wong BJF; Chen Z
    Sci Rep; 2016 Dec; 6():39443. PubMed ID: 27991580
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Bronchial Thermoplasty-Induced Acute Airway Effects Assessed with Optical Coherence Tomography in Severe Asthma.
    Goorsenberg AWM; d'Hooghe JNS; de Bruin DM; van den Berk IAH; Annema JT; Bonta PI
    Respiration; 2018; 96(6):564-570. PubMed ID: 30110691
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Airway obstruction in sheep with burn and smoke inhalation injuries.
    Cox RA; Burke AS; Soejima K; Murakami K; Katahira J; Traber LD; Herndon DN; Schmalstieg FC; Traber DL; Hawkins HK
    Am J Respir Cell Mol Biol; 2003 Sep; 29(3 Pt 1):295-302. PubMed ID: 12936906
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Optical coherence tomography for identification and quantification of human airway wall layers.
    d'Hooghe JNS; Goorsenberg AWM; de Bruin DM; Roelofs JJTH; Annema JT; Bonta PI
    PLoS One; 2017; 12(10):e0184145. PubMed ID: 28981500
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Detection and monitoring of early airway injury effects of half-mustard (2-chloroethylethylsulfide) exposure using high-resolution optical coherence tomography.
    Kreuter KA; Mahon SB; Mukai DS; Su J; Jung WG; Narula N; Guo S; Wakida N; Raub C; Berns MW; George SC; Chen Z; Brenner M
    J Biomed Opt; 2009; 14(4):044037. PubMed ID: 19725748
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Optical frequency domain imaging of ex vivo pulmonary resection specimens: obtaining one to one image to histopathology correlation.
    Hariri LP; Applegate MB; Mino-Kenudson M; Mark EJ; Bouma BE; Tearney GJ; Suter MJ
    J Vis Exp; 2013 Jan; (71):. PubMed ID: 23381470
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Imaging of the pediatric airway using optical coherence tomography.
    Ridgway JM; Ahuja G; Guo S; Su J; Mahmood U; Chen Z; Wong B
    Laryngoscope; 2007 Dec; 117(12):2206-12. PubMed ID: 18322424
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Optical coherence tomography in the diagnosis of bronchial lesions.
    Tsuboi M; Hayashi A; Ikeda N; Honda H; Kato Y; Ichinose S; Kato H
    Lung Cancer; 2005 Sep; 49(3):387-94. PubMed ID: 15922488
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Standardizing the diagnosis of inhalation injury using a descriptive score based on mucosal injury criteria.
    Ikonomidis C; Lang F; Radu A; Berger MM
    Burns; 2012 Jun; 38(4):513-9. PubMed ID: 22348802
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Real-time subglottic stenosis imaging using optical coherence tomography in the rabbit.
    Lin JL; Yau AY; Boyd J; Hamamoto A; Su E; Tracy L; Heidari AE; Wang AH; Ahuja G; Chen Z; Wong BJ
    JAMA Otolaryngol Head Neck Surg; 2013 May; 139(5):502-9. PubMed ID: 23681033
    [TBL] [Abstract][Full Text] [Related]  

  • 31. In vivo imaging of human labial glands using advanced optical coherence tomography.
    Ozawa N; Sumi Y; Shimozato K; Chong C; Kurabayashi T
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2009 Sep; 108(3):425-9. PubMed ID: 19716509
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Endoscopic Optical Coherence Tomography for Assessing Inhalation Airway Injury: A Technical Review.
    Miao Y; Brenner M; Chen Z
    Otolaryngol (Sunnyvale); 2019; 9(2):. PubMed ID: 31497378
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Akinetic swept-source optical coherence tomography based on a pulse-modulated active mode locking fiber laser for human retinal imaging.
    Lee HD; Kim GH; Shin JG; Lee B; Kim CS; Eom TJ
    Sci Rep; 2018 Dec; 8(1):17660. PubMed ID: 30518926
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Robot-assisted three-dimensional registration for cochlear implant surgery using a common-path swept-source optical coherence tomography probe.
    Gurbani SS; Wilkening P; Zhao M; Gonenc B; Cheon GW; Iordachita II; Chien W; Taylor RH; Niparko JK; Kang JU
    J Biomed Opt; 2014 May; 19(5):057004. PubMed ID: 24805810
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Optical coherence tomography as an adjunct to flexible bronchoscopy in the diagnosis of lung cancer: a pilot study.
    Michel RG; Kinasewitz GT; Fung KM; Keddissi JI
    Chest; 2010 Oct; 138(4):984-8. PubMed ID: 20472863
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Automated 3D segmentation of methyl isocyanate-exposed rat trachea using an ultra-thin, fully fiber optic optical coherence endoscopic probe.
    Miao Y; Jing JC; Desai V; Mahon SB; Brenner M; Veress LA; White CW; Chen Z
    Sci Rep; 2018 Jun; 8(1):8713. PubMed ID: 29880863
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Validation of airway wall measurements by optical coherence tomography in porcine airways.
    Lee AM; Kirby M; Ohtani K; Candido T; Shalansky R; MacAulay C; English J; Finley R; Lam S; Coxson HO; Lane P
    PLoS One; 2014; 9(6):e100145. PubMed ID: 24949633
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Dual-modality needle probe for combined fluorescence imaging and three-dimensional optical coherence tomography.
    Lorenser D; Quirk BC; Auger M; Madore WJ; Kirk RW; Godbout N; Sampson DD; Boudoux C; McLaughlin RA
    Opt Lett; 2013 Feb; 38(3):266-8. PubMed ID: 23381406
    [TBL] [Abstract][Full Text] [Related]  

  • 39. "The black bronchoscopy": a case of airway soot deposition.
    Ribeiro C; Guimarães M; Antunes A; Oliveira A; Neves S; Almeida J; Moura E Sá J
    J Bronchology Interv Pulmonol; 2013 Jul; 20(3):271-3. PubMed ID: 23857205
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Alterations in the neural and connective tissue components of glaucomatous cupping after glaucoma surgery using swept-source optical coherence tomography.
    Yoshikawa M; Akagi T; Hangai M; Ohashi-Ikeda H; Takayama K; Morooka S; Kimura Y; Nakano N; Yoshimura N
    Invest Ophthalmol Vis Sci; 2014 Jan; 55(1):477-84. PubMed ID: 24398100
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.