These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

160 related articles for article (PubMed ID: 24666355)

  • 1. Effect of Luting Agents on Retention of Dental Implant-Supported Prostheses.
    Pan YH; Lin TM; Liu PR; Ramp LC
    J Oral Implantol; 2015 Oct; 41(5):596-9. PubMed ID: 24666355
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effect of luting agents on the retention of dental implant-supported crowns.
    Pan YH; Lin CK
    Chang Gung Med J; 2005 Jun; 28(6):403-10. PubMed ID: 16124156
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Retention and leakage of implant-supported restorations luted with provisional cement: a pilot study.
    Pan YH; Ramp LC; Lin CK; Liu PR
    J Oral Rehabil; 2007 Mar; 34(3):206-12. PubMed ID: 17302949
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Retention of CAD/CAM all-ceramic crowns on prefabricated implant abutments: an in vitro comparative study of luting agents and abutment surface area.
    Carnaggio TV; Conrad R; Engelmeier RL; Gerngross P; Paravina R; Perezous L; Powers JM
    J Prosthodont; 2012 Oct; 21(7):523-8. PubMed ID: 22469271
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Cement selection for cement-retained crown technique with dental implants.
    Sheets JL; Wilcox C; Wilwerding T
    J Prosthodont; 2008 Feb; 17(2):92-96. PubMed ID: 17971122
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparative evaluation of casting retention using the ITI solid abutment with six cements.
    Mansour A; Ercoli C; Graser G; Tallents R; Moss M
    Clin Oral Implants Res; 2002 Aug; 13(4):343-8. PubMed ID: 12175370
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effect of thermal cycling and air abrasion on cement failure loads of 4 provisional luting agents used for the cementation of implant-supported fixed partial dentures.
    Michalakis K; Pissiotis AL; Kang K; Hirayama H; Garefis PD; Petridis H
    Int J Oral Maxillofac Implants; 2007; 22(4):569-74. PubMed ID: 17929517
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cement selection for implant-supported crowns fabricated with different luting space settings.
    Gultekin P; Gultekin BA; Aydin M; Yalcin S
    J Prosthodont; 2013 Feb; 22(2):112-9. PubMed ID: 23387964
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Retentiveness of various luting agents used with implant-supported prosthesis: an in vitro study.
    Garg P; Pujari M; Prithviraj DR; Khare S
    J Oral Implantol; 2014 Dec; 40(6):649-54. PubMed ID: 25506659
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Retentiveness of dental cements used with metallic implant components.
    Squier RS; Agar JR; Duncan JP; Taylor TD
    Int J Oral Maxillofac Implants; 2001; 16(6):793-8. PubMed ID: 11769829
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Influence of abutment height and surface roughness on in vitro retention of three luting agents.
    Cano-Batalla J; Soliva-Garriga J; Campillo-Funollet M; Munoz-Viveros CA; Giner-Tarrida L
    Int J Oral Maxillofac Implants; 2012; 27(1):36-41. PubMed ID: 22299076
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effects of abutment taper, length and cement type on resistance to dislodgement of cement-retained, implant-supported restorations.
    Bernal G; Okamura M; Muñoz CA
    J Prosthodont; 2003 Jun; 12(2):111-5. PubMed ID: 12964683
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Retention of implant-supported zirconium oxide ceramic restorations using different luting agents.
    Nejatidanesh F; Savabi O; Shahtoosi M
    Clin Oral Implants Res; 2013 Aug; 24 Suppl A100():20-4. PubMed ID: 22092303
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cement failure loads of 4 provisional luting agents used for the cementation of implant-supported fixed partial dentures.
    Michalakis KX; Pissiotis AL; Hirayama H
    Int J Oral Maxillofac Implants; 2000; 15(4):545-9. PubMed ID: 10960988
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The effect of fatigue damage on the force required to remove a restoration in a cement-retained implant system.
    Kaar D; Oshida Y; Andres CJ; Barco MT; Platt JA
    J Prosthodont; 2006; 15(5):289-94. PubMed ID: 16958729
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In vitro comparisons of casting retention on implant abutments among commercially available and experimental castor oil-containing dental luting agents.
    Pinelli LA; Fais LM; Ricci WA; Reis JM
    J Prosthet Dent; 2013 May; 109(5):319-24. PubMed ID: 23684282
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An in vitro assessment of circumferential grooves on the retention of cement-retained implant-supported crowns.
    Lewinstein I; Block L; Lehr Z; Ormianer Z; Matalon S
    J Prosthet Dent; 2011 Dec; 106(6):367-72. PubMed ID: 22133393
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The effect of air abrasion of metal implant abutments on the tensile bond strength of three luting agents used to cement implant superstructures: an in vitro study.
    Jugdev J; Borzabadi-Farahani A; Lynch E
    Int J Oral Maxillofac Implants; 2014; 29(4):784-90. PubMed ID: 25032757
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Retention of cast crown copings cemented to implant abutments.
    Dudley JE; Richards LC; Abbott JR
    Aust Dent J; 2008 Dec; 53(4):332-9. PubMed ID: 19133949
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Retentiveness of various luting agents used with implant-supported prostheses: a preliminary in vitro study.
    Garg P; Gupta G; Prithviraj DR; Pujari M
    Int J Prosthodont; 2013; 26(1):82-4. PubMed ID: 23342339
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.