These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 24666949)

  • 1. High-pressure-low-temperature cryostat designed for use with fourier transform infrared spectrometers and time-resolved infrared spectroscopy.
    Calladine JA; Love A; Fields PA; Wilson RG; George MW
    Appl Spectrosc; 2014; 68(3):324-31. PubMed ID: 24666949
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A new, low temperature long-pass cell for mid-infrared to terahertz spectroscopy and synchrotron radiation use.
    Kwabia Tchana F; Willaert F; Landsheere X; Flaud JM; Lago L; Chapuis M; Herbeaux C; Roy P; Manceron L
    Rev Sci Instrum; 2013 Sep; 84(9):093101. PubMed ID: 24089810
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Cell design for picosecond time-resolved infrared spectroscopy in high-pressure liquids and supercritical fluids.
    Sun XZ; Portius P; Grills DC; Cowan AJ; George MW
    Appl Spectrosc; 2008 Jan; 62(1):24-9. PubMed ID: 18230203
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Time-resolved rapid-scan Fourier transform infrared difference spectroscopy on a noncyclic photosystem: rhodopsin photointermediates from Lumi to Meta II.
    Lüdeke S; Lórenz Fonfría VA; Siebert F; Vogel R
    Biopolymers; 2006 Oct; 83(2):159-69. PubMed ID: 16721790
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Infrared spectroscopy of organometallic ions in the gas phase: from model to real world complexes.
    MacAleese L; Maître P
    Mass Spectrom Rev; 2007; 26(4):583-605. PubMed ID: 17471578
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Design and performance of a flow-through polarization-modulation infrared reflection-absorption spectroscopy cell for time-resolved simultaneous surface and liquid phase detection under concentration and temperature perturbations.
    Meier DM; Urakawa A; Mäder R; Baiker A
    Rev Sci Instrum; 2009 Sep; 80(9):094101. PubMed ID: 19791951
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Application of external-cavity quantum cascade infrared lasers to nanosecond time-resolved infrared spectroscopy of condensed-phase samples following pulse radiolysis.
    Grills DC; Cook AR; Fujita E; George MW; Preses JM; Wishart JF
    Appl Spectrosc; 2010 Jun; 64(6):563-70. PubMed ID: 20537222
    [TBL] [Abstract][Full Text] [Related]  

  • 8. High-temperature multipass cell for infrared spectroscopy of heated gases and vapors.
    Bartlome R; Baer M; Sigrist MW
    Rev Sci Instrum; 2007 Jan; 78(1):013110. PubMed ID: 17503910
    [TBL] [Abstract][Full Text] [Related]  

  • 9. How to make big molecules fly out of liquid water: applications, features and physics of laser assisted liquid phase dispersion mass spectrometry.
    Charvat A; Abel B
    Phys Chem Chem Phys; 2007 Jul; 9(26):3335-60. PubMed ID: 17664960
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pressure jump relaxation setup with IR detection and millisecond time resolution.
    Schiewek M; Krumova M; Hempel G; Blume A
    Rev Sci Instrum; 2007 Apr; 78(4):045101. PubMed ID: 17477687
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fourier transform infrared difference spectroscopy of photosystem II tyrosine D using site-directed mutagenesis and specific isotope labeling.
    Hienerwadel R; Boussac A; Breton J; Diner BA; Berthomieu C
    Biochemistry; 1997 Dec; 36(48):14712-23. PubMed ID: 9398191
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Adding diffuse reflectance infrared Fourier transform spectroscopy capability to extended x-ray-absorption fine structure in a new cell to study solid catalysts in combination with a modulation approach.
    Chiarello GL; Nachtegaal M; Marchionni V; Quaroni L; Ferri D
    Rev Sci Instrum; 2014 Jul; 85(7):074102. PubMed ID: 25085153
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Generation and characterization of the selenocysteinyl radical: direct evidence from time-resolved UV/Vis, electron paramagnetic resonance, and Fourier transform infrared spectroscopy.
    Kolano C; Bucher G; Schade O; Grote D; Sander W
    J Org Chem; 2005 Aug; 70(17):6609-15. PubMed ID: 16095277
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Continuous online Fourier transform infrared (FT-IR) spectrometry analysis of hydrogen chloride (HCl), carbon dioxide (CO2), and water (H2O) in nitrogen-rich and ethylene-rich streams.
    Stephenson S; Pollard M; Boit K
    Appl Spectrosc; 2013 Sep; 67(9):1019-28. PubMed ID: 24067632
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of dense gas CO2 on the coacervation of elastin.
    Dehghani F; Annabi N; Valtchev P; Mithieux SM; Weiss AS; Kazarian SG; Tay FH
    Biomacromolecules; 2008 Apr; 9(4):1100-5. PubMed ID: 18363358
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Low-frequency fourier transform infrared spectroscopy of the oxygen-evolving and quinone acceptor complexes in photosystem II.
    Chu HA; Gardner MT; O'Brien JP; Babcock GT
    Biochemistry; 1999 Apr; 38(14):4533-41. PubMed ID: 10194375
    [TBL] [Abstract][Full Text] [Related]  

  • 17. High-sensitivity Raman spectrometer to study pristine and irradiated interstellar ice analogs.
    Bennett CJ; Brotton SJ; Jones BM; Misra AK; Sharma SK; Kaiser RI
    Anal Chem; 2013 Jun; 85(12):5659-65. PubMed ID: 23662702
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Coupling Pulse Radiolysis with Nanosecond Time-Resolved Step-Scan Fourier Transform Infrared Spectroscopy: Broadband Mid-Infrared Detection of Radiolytically Generated Transients.
    Grills DC; Layne BH; Wishart JF
    Appl Spectrosc; 2022 Sep; 76(9):1142-1153. PubMed ID: 35414202
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Novel high-temperature and pressure-compatible ultrasonic levitator apparatus coupled to Raman and Fourier transform infrared spectrometers.
    Brotton SJ; Kaiser RI
    Rev Sci Instrum; 2013 May; 84(5):055114. PubMed ID: 23742596
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Mid-infrared, long wave infrared (4-12 μm) molecular emission signatures from pharmaceuticals using laser-induced breakdown spectroscopy (LIBS).
    Yang CS; Brown EE; Kumi-Barimah E; Hommerich UH; Jin F; Trivedi SB; Samuels AC; Snyder AP
    Appl Spectrosc; 2014; 68(2):226-31. PubMed ID: 24480279
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.