These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 2468142)

  • 1. Reliability of minute ventilation as a parameter for rate responsive pacing.
    Lau CP; Antoniou A; Ward DE; Camm AJ
    Pacing Clin Electrophysiol; 1989 Feb; 12(2):321-30. PubMed ID: 2468142
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Clinical experience with Sensolog 703: a new activity sensing rate responsive pacemaker.
    Lau CP; Tse WS; Camm AJ
    Pacing Clin Electrophysiol; 1988 Oct; 11(10):1444-55. PubMed ID: 2462222
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Initial clinical experience with a minute ventilation sensing rate modulated pacemaker: improvements in exercise capacity and symptomatology.
    Lau CP; Antoniou A; Ward DE; Camm AJ
    Pacing Clin Electrophysiol; 1988 Nov; 11(11 Pt 2):1815-22. PubMed ID: 2463552
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Rate responsive pacing using a minute ventilation sensor.
    Mond H; Strathmore N; Kertes P; Hunt D; Baker G
    Pacing Clin Electrophysiol; 1988 Nov; 11(11 Pt 2):1866-74. PubMed ID: 2463560
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Rate responsive cardiac pacing using a minute ventilation sensor.
    Abrahamsen AM; Barvik S; Aarsland T; Dickstein K
    Pacing Clin Electrophysiol; 1993 Aug; 16(8):1650-5. PubMed ID: 7690933
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Rate-modulated cardiac pacing based on transthoracic impedance measurements of minute ventilation: correlation with exercise gas exchange.
    Kay GN; Bubien RS; Epstein AE; Plumb VJ
    J Am Coll Cardiol; 1989 Nov; 14(5):1283-9. PubMed ID: 2808984
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Superior cardiac hemodynamics of atrioventricular synchrony over rate responsive pacing at submaximal exercise: observations in activity sensing DDDR pacemakers.
    Lau CP; Wong CK; Leung WH; Liu WX
    Pacing Clin Electrophysiol; 1990 Dec; 13(12 Pt 2):1832-7. PubMed ID: 1704550
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Role of left ventricular function and Doppler-derived variables in predicting hemodynamic benefits of rate-responsive pacing.
    Lau CP; Camm AJ
    Am J Cardiol; 1988 Nov; 62(13):906-11. PubMed ID: 3177239
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reliability of the evoked response in determining the paced ventricular rate and performance of the QT or rate responsive (TX) pacemaker.
    Fananapazir L; Rademaker M; Bennett DH
    Pacing Clin Electrophysiol; 1985 Sep; 8(5):701-14. PubMed ID: 2414752
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Measurements of cardiac output by impedance cardiography in pacemaker patients at rest: effects of various atrioventricular delays.
    Ovsyshcher I; Zimlichman R; Katz A; Bondy C; Furman S
    J Am Coll Cardiol; 1993 Mar; 21(3):761-7. PubMed ID: 8436759
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Rate adaptive cardiac pacing using right ventricular venous oxygen saturation: quantification of chronotropic behavior during daily activities and maximal exercise.
    Lau CP; Tai YT; Leung WH; Leung SK; Li JP; Wong CK; Lee IS; Yerich C; Erickson M
    Pacing Clin Electrophysiol; 1994 Dec; 17(12 Pt 1):2236-46. PubMed ID: 7885930
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Impact of adaptive rate pacing controlled by a right ventricular impedance sensor on cardiac output in response to exercise.
    Cook L; Hamilton D; Busse E; Tsang J; Garbe G; Wojcik W; Haennel R
    Pacing Clin Electrophysiol; 2003 Jan; 26(1P2):244-7. PubMed ID: 12687821
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dual sensor VVIR mode pacing: is it worth it?
    Sulke N; Tan K; Kamalvand K; Bostock J; Bucknall C
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 1):1560-7. PubMed ID: 8946451
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Effects of chronotropic responsive cardiac pacing on ventilatory response to exercise in patients with bradycardia].
    Tani M; Fujiki A; Asanoi H; Mizumaki K; Yoshida S; Tsuji H; Sasayama S
    J Cardiol; 1992; 22(2-3):503-12. PubMed ID: 1339809
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A comparative evaluation of a minute ventilation sensing and activity sensing adaptive-rate pacemakers during daily activities.
    Lau CP; Wong CK; Leung WH; Cheng CH; Lo CW
    Pacing Clin Electrophysiol; 1989 Sep; 12(9):1514-21. PubMed ID: 2476780
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effects of chronotropic responsive cardiac pacing on ventilatory response to exercise in patients with complete AV block.
    Tani M; Fujiki A; Asanoi H; Yoshida S; Tsuji H; Mizumaki K; Sasayama S
    Pacing Clin Electrophysiol; 1992 Oct; 15(10 Pt 1):1482-91. PubMed ID: 1383960
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Activity-sensing rate responsive versus conventional fixed-rate pacing: a comparison of rate behavior and patient well-being during routine daily exercise.
    Candinas RA; Gloor HO; Amann FW; Schoenbeck M; Turina M
    Pacing Clin Electrophysiol; 1991 Feb; 14(2 Pt 1):204-13. PubMed ID: 1706506
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A comparative study of activity and dual sensor: activity and minute ventilation pacing responses to ascending and descending stairs.
    Alt E; Combs W; Willhaus R; Condie C; Bambl E; Fotuhi P; Pache J; Schömig A
    Pacing Clin Electrophysiol; 1998 Oct; 21(10):1862-8. PubMed ID: 9793080
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Exercise hemodynamic benefits of rate adaptive ventricular pacing.
    Ma J; Wang F; Zhang K; Yu P; Wang J; Chen X
    Chin Med J (Engl); 1996 Jun; 109(6):459-62. PubMed ID: 9206079
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Usefulness of transcutaneous triggering of conventional implanted pulse generators by an activity-sensing pacemaker for predicting effectiveness of rate response pacing.
    Fetter J; Benditt DG; Mianulli M
    Am J Cardiol; 1988 Nov; 62(13):901-5. PubMed ID: 3177238
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.