330 related articles for article (PubMed ID: 24687307)
1. Performances of capillary electrophoresis and HPLC methods in HbA1c determination: diagnostic accuracy in HbS and HbD-Iran variants' presence.
Dessi M; Pieri M; Pignalosa S; Martino FG; Zenobi R
J Clin Lab Anal; 2015 Jan; 29(1):57-60. PubMed ID: 24687307
[TBL] [Abstract][Full Text] [Related]
2. A comparative evaluation of the analytical performances of Capillarys 2 Flex Piercing, Tosoh HLC-723 G8, Premier Hb9210, and Roche Cobas c501 Tina-quant Gen 2 analyzers for HbA
Wu X; Chao Y; Wan Z; Wang Y; Ma Y; Ke P; Wu X; Xu J; Zhuang J; Huang X
Biochem Med (Zagreb); 2016 Oct; 26(3):353-364. PubMed ID: 27812304
[TBL] [Abstract][Full Text] [Related]
3. New HPLC instrument performance evaluation in HbA
Khashoggi H; Pignalosa S; Russo C; Pieri M; Bernardini S
Scand J Clin Lab Invest; 2018 Sep; 78(5):393-397. PubMed ID: 29993292
[TBL] [Abstract][Full Text] [Related]
4. Erroneous HbA1c measurements in the presence of β-thalassemia and common Chinese hemoglobin variants.
Ji L; Yu J; Zhou Y; Xia Y; Xu A; Li W; Li L
Clin Chem Lab Med; 2015 Aug; 53(9):1451-8. PubMed ID: 25720069
[TBL] [Abstract][Full Text] [Related]
5. Hemoglobin Yamagata [β132(H10)Lys→Asn; (
Iacomelli I; Barberio G; Pucci P; Monaco V; Maffei M; Mogni M; Curcio C; Maoggi S; Giulietti C; Harteveld CL; Ivaldi G
Clin Chem Lab Med; 2021 Sep; 59(10):1670-1679. PubMed ID: 33887814
[TBL] [Abstract][Full Text] [Related]
6. Hb variants in Korea: effect on HbA1c using five routine methods.
Yun YM; Ji M; Ko DH; Chun S; Kwon GC; Lee K; Song SH; Seong MW; Park SS; Song J
Clin Chem Lab Med; 2017 Jul; 55(8):1234-1242. PubMed ID: 28107170
[TBL] [Abstract][Full Text] [Related]
7. Hemoglobin S monitoring on TOSOH G8 in hemoglobin A1c mode in case of urgent red blood cell exchange.
Van Aelst S; Claerhout H; Nackers E; Desmet K; Kieffer D
J Clin Lab Anal; 2018 Sep; 32(7):e22453. PubMed ID: 29667731
[TBL] [Abstract][Full Text] [Related]
8. First evaluation of Capillarys 2 Flex Piercing® (Sebia) as a new analyzer for HbA1c assay by capillary electrophoresis.
Jaisson S; Leroy N; Meurice J; Guillard E; Gillery P
Clin Chem Lab Med; 2012 Oct; 50(10):1769-75. PubMed ID: 23089707
[TBL] [Abstract][Full Text] [Related]
9. HbA1c analysis by capillary electrophoresis - comparison with chromatography and an immunological method.
Klingenberg O; Furuset T; Hestbråten CR; Hallberg MH; Steiro A; Orset IR; Berg JP
Scand J Clin Lab Invest; 2017 Oct; 77(6):458-464. PubMed ID: 28644050
[TBL] [Abstract][Full Text] [Related]
10. Effects of 49 Different Rare Hb Variants on HbA1c Measurement in Eight Methods.
Little RR; La'ulu SL; Hanson SE; Rohlfing CL; Schmidt RL
J Diabetes Sci Technol; 2015 Jul; 9(4):849-56. PubMed ID: 25691657
[TBL] [Abstract][Full Text] [Related]
11. Evaluation of the Sebia CAPILLARYS 2 flex piercing for the measurement of HbA(1c) on venous and capillary blood samples.
Heylen O; Van Neyghem S; Exterbille S; Wehlou C; Gorus F; Weets I
Am J Clin Pathol; 2014 Jun; 141(6):867-77. PubMed ID: 24838332
[TBL] [Abstract][Full Text] [Related]
12. Comparison of Two High-Pressure Liquid Chromatography Instruments Bio-Rad Variant-II and Tosoh HLC-723G11 in the Evaluation of Hemoglobinopathies.
Chopra P; Bhardwaj S; Negi P; Arora A
Indian J Hematol Blood Transfus; 2020 Oct; 36(4):725-732. PubMed ID: 33100717
[TBL] [Abstract][Full Text] [Related]
13. Identification of Hemoglobin Variants Prevalent in China and Their Effects on Hemoglobin A1c Measurements.
Xu A; Chen W; Xu M; Xie W; Ji L
Am J Clin Pathol; 2022 Jun; 157(6):852-857. PubMed ID: 34871348
[TBL] [Abstract][Full Text] [Related]
14. Identification of Hb Wayne and its effects on HbA1c measurement by 5 methods.
Rodríguez-Capote K; Estey MP; Barakauskas VE; Burton T; Holmes D; Krause R; Higgins TN
Clin Biochem; 2015 Nov; 48(16-17):1144-50. PubMed ID: 26247176
[TBL] [Abstract][Full Text] [Related]
15. Hemoglobin fractionation by Sebia Capillarys 2 Flex Piercing System as primary method for evaluation of hemoglobinopathies.
Poventud-Fuentes I; Garnett E; Vispo B; Elghetany MT; Devaraj S
Clin Chim Acta; 2021 Aug; 519():193-197. PubMed ID: 33939955
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of the V8 E-Class, a Novel Automated Capillary Isoelectric Focusing Instrument for Hemoglobinopathy Screening.
Schiemsky T; Brusselmans C; Nackers E; Vermeersch P; Poesen K; Desmet KJ; Boeckx N; Kieffer DM
Am J Clin Pathol; 2016 Sep; 146(3):361-8. PubMed ID: 27543981
[TBL] [Abstract][Full Text] [Related]
17. Accurate and Rapid Measurement of Glycated Hemoglobin Using HLC-723 G11 Variant Mode.
Park MS; Lee K; Lee K; Song J; Park HD
Ann Lab Med; 2019 May; 39(3):237-244. PubMed ID: 30623615
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of four hemoglobin separation analyzers for hemoglobinopathy diagnosis.
Degandt S; Coens R; Cauwelier B; Devos H; Langlois M; Emmerechts J
J Clin Lab Anal; 2018 Jan; 32(1):. PubMed ID: 28383138
[TBL] [Abstract][Full Text] [Related]
19. Differential Effects on HbA1c Detection by HPLC and Capillary Electrophoresis in Five Types of Hb Variants in China.
Wei L; Weifeng Z; Zuoliang D
Lab Med; 2023 May; 54(3):308-316. PubMed ID: 36242591
[TBL] [Abstract][Full Text] [Related]
20. Influence of RBC Indices on HbA1c Measurement by Capillary Electrophoresis and HPLC Methods.
Juang YJ; Wu HM; Cheng YW; Eng HL; Lin TM
Clin Lab; 2022 Aug; 68(8):. PubMed ID: 35975502
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]