These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 24689625)

  • 1. Atomic resolution scanning tunneling microscopy in a cryogen free dilution refrigerator at 15 mK.
    den Haan AM; Wijts GH; Galli F; Usenko O; van Baarle GJ; van der Zalm DJ; Oosterkamp TH
    Rev Sci Instrum; 2014 Mar; 85(3):035112. PubMed ID: 24689625
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development of a near-5-Kelvin, cryogen-free, pulse-tube refrigerator-based scanning probe microscope.
    Kasai J; Koyama T; Yokota M; Iwaya K
    Rev Sci Instrum; 2022 Apr; 93(4):043711. PubMed ID: 35489903
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Design of a scanning gate microscope for mesoscopic electron systems in a cryogen-free dilution refrigerator.
    Pelliccione M; Sciambi A; Bartel J; Keller AJ; Goldhaber-Gordon D
    Rev Sci Instrum; 2013 Mar; 84(3):033703. PubMed ID: 23556823
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Vibration isolation with high thermal conductance for a cryogen-free dilution refrigerator.
    de Wit M; Welker G; Heeck K; Buters FM; Eerkens HJ; Koning G; van der Meer H; Bouwmeester D; Oosterkamp TH
    Rev Sci Instrum; 2019 Jan; 90(1):015112. PubMed ID: 30709182
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A six-degree-of-freedom micro-vibration acoustic isolator for low-temperature radiation detectors based on superconducting transition-edge sensors.
    Gottardi L; van Weers H; Dercksen J; Akamatsu H; Bruijn MP; Gao JR; Jackson B; Khosropanah P; van der Kuur J; Ravensberg K; Ridder ML
    Rev Sci Instrum; 2019 May; 90(5):055107. PubMed ID: 31153243
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Design and performance of an ultra-high vacuum scanning tunneling microscope operating at dilution refrigerator temperatures and high magnetic fields.
    Misra S; Zhou BB; Drozdov IK; Seo J; Urban L; Gyenis A; Kingsley SC; Jones H; Yazdani A
    Rev Sci Instrum; 2013 Oct; 84(10):103903. PubMed ID: 24182125
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A scanning tunneling microscope for a dilution refrigerator.
    Marz M; Goll G; Löhneysen Hv
    Rev Sci Instrum; 2010 Apr; 81(4):045102. PubMed ID: 20441363
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cryogen free spin polarized scanning tunneling microscopy and magnetic exchange force microscopy with extremely low noise.
    Huang H; Shuai M; Yang Y; Song R; Liao Y; Yin L; Shen J
    Rev Sci Instrum; 2022 Jul; 93(7):073703. PubMed ID: 35922334
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Invited review article: A 10 mK scanning probe microscopy facility.
    Song YJ; Otte AF; Shvarts V; Zhao Z; Kuk Y; Blankenship SR; Band A; Hess FM; Stroscio JA
    Rev Sci Instrum; 2010 Dec; 81(12):121101. PubMed ID: 21198007
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Scanning SQUID microscopy in a cryogen-free dilution refrigerator.
    Low D; Ferguson GM; Jarjour A; Schaefer BT; Bachmann MD; Moll PJW; Nowack KC
    Rev Sci Instrum; 2021 Aug; 92(8):083704. PubMed ID: 34470407
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development of a cryogen-free sub-3 K low-temperature scanning probe microscope by remote liquefaction scheme.
    Ma R; Li H; Shi C; Wang F; Lei L; Huang Y; Liu Y; Shan H; Liu L; Huang S; Niu ZC; Huan Q; Gao HJ
    Rev Sci Instrum; 2023 Sep; 94(9):. PubMed ID: 37671954
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A compact sub-Kelvin ultrahigh vacuum scanning tunneling microscope with high energy resolution and high stability.
    Zhang L; Miyamachi T; Tomanić T; Dehm R; Wulfhekel W
    Rev Sci Instrum; 2011 Oct; 82(10):103702. PubMed ID: 22047298
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Achieving μeV tunneling resolution in an in-operando scanning tunneling microscopy, atomic force microscopy, and magnetotransport system for quantum materials research.
    Schwenk J; Kim S; Berwanger J; Ghahari F; Walkup D; Slot MR; Le ST; Cullen WG; Blankenship SR; Vranjkovic S; Hug HJ; Kuk Y; Giessibl FJ; Stroscio JA
    Rev Sci Instrum; 2020 Jul; 91(7):071101. PubMed ID: 32752869
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A 30 mK, 13.5 T scanning tunneling microscope with two independent tips.
    Roychowdhury A; Gubrud MA; Dana R; Anderson JR; Lobb CJ; Wellstood FC; Dreyer M
    Rev Sci Instrum; 2014 Apr; 85(4):043706. PubMed ID: 24784617
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Vibration-induced electrical noise in a cryogen-free dilution refrigerator: Characterization, mitigation, and impact on qubit coherence.
    Kalra R; Laucht A; Dehollain JP; Bar D; Freer S; Simmons S; Muhonen JT; Morello A
    Rev Sci Instrum; 2016 Jul; 87(7):073905. PubMed ID: 27475569
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Facility for low-temperature spin-polarized-scanning tunneling microscopy studies of magnetic/spintronic materials prepared in situ by nitride molecular beam epitaxy.
    Lin W; Foley A; Alam K; Wang K; Liu Y; Chen T; Pak J; Smith AR
    Rev Sci Instrum; 2014 Apr; 85(4):043702. PubMed ID: 24784613
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Construction and performance of a dilution-refrigerator based spectroscopic-imaging scanning tunneling microscope.
    Singh UR; Enayat M; White SC; Wahl P
    Rev Sci Instrum; 2013 Jan; 84(1):013708. PubMed ID: 23387660
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A Novel Atomically Resolved Scanning Tunneling Microscope Capable of Working in Cryogen-Free Superconducting Magnet.
    Geng T; Wang J; Meng W; Zhang J; Feng Q; Hou Y; Lu Q
    Micromachines (Basel); 2023 Mar; 14(3):. PubMed ID: 36985044
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Construction of a dilution refrigerator cooled scanning force microscope.
    Gildemeister AE; Ihn T; Barengo C; Studerus P; Ensslin K
    Rev Sci Instrum; 2007 Jan; 78(1):013704. PubMed ID: 17503925
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Combined low-temperature scanning tunneling/atomic force microscope for atomic resolution imaging and site-specific force spectroscopy.
    Albers BJ; Liebmann M; Schwendemann TC; Baykara MZ; Heyde M; Salmeron M; Altman EI; Schwarz UD
    Rev Sci Instrum; 2008 Mar; 79(3):033704. PubMed ID: 18377012
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.