148 related articles for article (PubMed ID: 24694398)
1. Microfluidic perfusion cell culture system confined in 35 mm culture dish for standard biological laboratories.
Kondo E; Wada K; Hosokawa K; Maeda M
J Biosci Bioeng; 2014 Sep; 118(3):356-8. PubMed ID: 24694398
[TBL] [Abstract][Full Text] [Related]
2. Optimal periodic perfusion strategy for robust long-term microfluidic cell culture.
Giulitti S; Magrofuoco E; Prevedello L; Elvassore N
Lab Chip; 2013 Nov; 13(22):4430-41. PubMed ID: 24064704
[TBL] [Abstract][Full Text] [Related]
3. Handheld recirculation system and customized media for microfluidic cell culture.
Futai N; Gu W; Song JW; Takayama S
Lab Chip; 2006 Jan; 6(1):149-54. PubMed ID: 16372083
[TBL] [Abstract][Full Text] [Related]
4. Micro-perfusion for cardiac tissue engineering: development of a bench-top system for the culture of primary cardiac cells.
Khait L; Hecker L; Radnoti D; Birla RK
Ann Biomed Eng; 2008 May; 36(5):713-25. PubMed ID: 18274906
[TBL] [Abstract][Full Text] [Related]
5. Microfluidic cell culture chip with multiplexed medium delivery and efficient cell/scaffold loading mechanisms for high-throughput perfusion 3-dimensional cell culture-based assays.
Huang SB; Wu MH; Wang SS; Lee GB
Biomed Microdevices; 2011 Jun; 13(3):415-30. PubMed ID: 21234690
[TBL] [Abstract][Full Text] [Related]
6. An integrated microfluidic system for long-term perfusion culture and on-line monitoring of intestinal tissue models.
Kimura H; Yamamoto T; Sakai H; Sakai Y; Fujii T
Lab Chip; 2008 May; 8(5):741-6. PubMed ID: 18432344
[TBL] [Abstract][Full Text] [Related]
7. Perfusion culture of mammalian cells in a microfluidic channel with a built-in pillar array.
Zhang C
Methods Mol Biol; 2012; 853():83-94. PubMed ID: 22323142
[TBL] [Abstract][Full Text] [Related]
8. Microfluidic perfusion culture of human induced pluripotent stem cells under fully defined culture conditions.
Yoshimitsu R; Hattori K; Sugiura S; Kondo Y; Yamada R; Tachikawa S; Satoh T; Kurisaki A; Ohnuma K; Asashima M; Kanamori T
Biotechnol Bioeng; 2014 May; 111(5):937-47. PubMed ID: 24222619
[TBL] [Abstract][Full Text] [Related]
9. Microfluidic array for three-dimensional perfusion culture of human mammary epithelial cells.
Chen SY; Hung PJ; Lee PJ
Biomed Microdevices; 2011 Aug; 13(4):753-8. PubMed ID: 21556741
[TBL] [Abstract][Full Text] [Related]
10. Real-time and non-invasive impedimetric monitoring of cell proliferation and chemosensitivity in a perfusion 3D cell culture microfluidic chip.
Lei KF; Wu MH; Hsu CW; Chen YD
Biosens Bioelectron; 2014 Jan; 51():16-21. PubMed ID: 23920091
[TBL] [Abstract][Full Text] [Related]
11. Pressure-driven perfusion culture microchamber array for a parallel drug cytotoxicity assay.
Sugiura S; Edahiro J; Kikuchi K; Sumaru K; Kanamori T
Biotechnol Bioeng; 2008 Aug; 100(6):1156-65. PubMed ID: 18553395
[TBL] [Abstract][Full Text] [Related]
12. Microfluidic arrays for logarithmically perfused embryonic stem cell culture.
Kim L; Vahey MD; Lee HY; Voldman J
Lab Chip; 2006 Mar; 6(3):394-406. PubMed ID: 16511623
[TBL] [Abstract][Full Text] [Related]
13. Continuous perfusion microfluidic cell culture array for high-throughput cell-based assays.
Hung PJ; Lee PJ; Sabounchi P; Lin R; Lee LP
Biotechnol Bioeng; 2005 Jan; 89(1):1-8. PubMed ID: 15580587
[TBL] [Abstract][Full Text] [Related]
14. NanoLiterBioReactor: long-term mammalian cell culture at nanofabricated scale.
Prokop A; Prokop Z; Schaffer D; Kozlov E; Wikswo J; Cliffel D; Baudenbacher F
Biomed Microdevices; 2004 Dec; 6(4):325-39. PubMed ID: 15548879
[TBL] [Abstract][Full Text] [Related]
15. Dielectrophoretic cell capture on polyester membranes.
Hanke C; Dittrich PS; Reyes DR
ACS Appl Mater Interfaces; 2012 Apr; 4(4):1878-82. PubMed ID: 22462623
[TBL] [Abstract][Full Text] [Related]
16. A palmtop-sized microfluidic cell culture system driven by a miniaturized infusion pump.
Sasaki N; Shinjo M; Hirakawa S; Nishinaka M; Tanaka Y; Mawatari K; Kitamori T; Sato K
Electrophoresis; 2012 Jul; 33(12):1729-35. PubMed ID: 22740461
[TBL] [Abstract][Full Text] [Related]
17. Microfluidic PDMS (polydimethylsiloxane) bioreactor for large-scale culture of hepatocytes.
Leclerc E; Sakai Y; Fujii T
Biotechnol Prog; 2004; 20(3):750-5. PubMed ID: 15176878
[TBL] [Abstract][Full Text] [Related]
18. Technical and theoretical considerations about gradient perfusion culture for epithelia used in tissue engineering, biomaterial testing and pharmaceutical research.
Minuth WW; Strehl R
Biomed Mater; 2007 Jun; 2(2):R1-R11. PubMed ID: 18458434
[TBL] [Abstract][Full Text] [Related]
19. A practical guide to microfluidic perfusion culture of adherent mammalian cells.
Kim L; Toh YC; Voldman J; Yu H
Lab Chip; 2007 Jun; 7(6):681-94. PubMed ID: 17538709
[TBL] [Abstract][Full Text] [Related]
20. A micro-channel-well system for culture and differentiation of embryonic stem cells on different types of substrate.
Liu L; Luo C; Ni X; Wang L; Yamauchi K; Nomura SM; Nakatsuji N; Chen Y
Biomed Microdevices; 2010 Jun; 12(3):505-11. PubMed ID: 20177790
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]