These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 24697111)

  • 1. Analytical performance of the Axis-Shield Afinion for hemoglobin A1c measurement: impact of lot number.
    Dupuy AM; Badiou S; Elong-Bertard C; Bargnoux AS; Cristol JP
    Clin Lab; 2014; 60(3):369-76. PubMed ID: 24697111
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy and precision of the Axis-Shield Afinion hemoglobin A1c measurement device.
    Wood JR; Kaminski BM; Kollman C; Beck RW; Hall CA; Yun JP; Cengiz E; Haller MJ; Hassan K; Klingensmith GJ; Tamborlane WV
    J Diabetes Sci Technol; 2012 Mar; 6(2):380-6. PubMed ID: 22538150
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Analysis of the accuracy and precision of the Axis-Shield Afinion hemoglobin A1c measurement device.
    Little RR
    J Diabetes Sci Technol; 2012 Mar; 6(2):387-8. PubMed ID: 22538151
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of two HbA1c point-of-care analyzers.
    Sánchez-Mora C; S Rodríguez-Oliva M; Fernández-Riejos P; Mateo J; Polo-Padillo J; Goberna R; Sánchez-Margalet V
    Clin Chem Lab Med; 2011 Apr; 49(4):653-7. PubMed ID: 21323623
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Comparison of HbA1c analyzers: D-10, Variant II Turbo, Cobas Integra 800, and Afinion AS100].
    Lee JY; Hong KS; Cho SE
    Korean J Lab Med; 2010 Aug; 30(4):345-50. PubMed ID: 20805705
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Six of eight hemoglobin A1c point-of-care instruments do not meet the general accepted analytical performance criteria.
    Lenters-Westra E; Slingerland RJ
    Clin Chem; 2010 Jan; 56(1):44-52. PubMed ID: 19926777
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Assessment of Two Diabetes Point-of-care Analyzers Measuring Hemoglobin A1c in the Peruvian Amazon.
    Saxton AT; Miranda JJ; Ortiz EJ; Pan W
    Ann Glob Health; 2018 Nov; 84(4):618-624. PubMed ID: 30779508
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Performance of Afinion HbA1c measurements in general practice as judged by external quality assurance data.
    Stavelin A; Flesche K; Tollaanes M; Christensen NG; Sandberg S
    Clin Chem Lab Med; 2020 Mar; 58(4):588-596. PubMed ID: 31821164
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hemoglobin A1c: assessment of three POC analyzers relative to a central laboratory method.
    Petersen JR; Omoruyi FO; Mohammad AA; Shea TJ; Okorodudu AO; Ju H
    Clin Chim Acta; 2010 Dec; 411(23-24):2062-6. PubMed ID: 20832393
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of three hemoglobin A1c point-of-care systems for glucose monitoring in patients with diabetes mellitus.
    Torregrosa ME; Molina J; Argente CR; Ena J
    Endocrinol Nutr; 2015 Dec; 62(10):478-84. PubMed ID: 26531840
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Can the Afinion HbA1c Point-of-Care instrument be an alternative method for the Tosoh G8 in the case of Hb-Tacoma?
    Lenters-Westra E; Strunk A; Campbell P; Slingerland RJ
    Scand J Clin Lab Invest; 2017 Feb; 77(1):2-7. PubMed ID: 27191339
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Good correlation between the Afinion AS100 analyser and the ABX Pentra 400 analyser for the measurement of glycosylated haemoglobin and lipid levels in older adults in Durban, South Africa.
    Abbai NS; Nyirenda M; Reddy T; Ramjee G
    S Afr Med J; 2017 Dec; 108(1):50-55. PubMed ID: 29262979
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fingerstick Precision and Total Error of a Point-of-Care HbA1c Test.
    Arnold WD; Kupfer K; Hvidsten Swensen M; Fortner KS; Bays HE; Davis M; Klaff LJ; San George RC
    J Diabetes Sci Technol; 2020 Sep; 14(5):890-895. PubMed ID: 30841743
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Capillary HbA1c determination on type 2 diabetes patients in a primary health centre].
    Font MT; Brichs MC; Álvarez MC; Olivella JM; Turó JS; Fernández MP
    Aten Primaria; 2011 Oct; 43(10):536-43. PubMed ID: 21411189
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Diagnosing diabetes mellitus: performance of hemoglobin A1c point-of-care instruments in general practice offices.
    Sølvik UØ; Røraas T; Christensen NG; Sandberg S
    Clin Chem; 2013 Dec; 59(12):1790-801. PubMed ID: 23958846
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of Three Hemoglobin A1c Point-of-Care Instruments.
    Criel M; Jonckheere S; Langlois M
    Clin Lab; 2016; 62(3):285-91. PubMed ID: 27156315
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Haemoglobin A1c: comparing performance of two point of care devices with laboratory analyser.
    Wan Mohd Zin RM; Ahmad Kamil ZI; Tuan Soh TR; Embong M; Wan Mohamud WN
    BMC Res Notes; 2013 Dec; 6():540. PubMed ID: 24344903
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Three of 7 hemoglobin A1c point-of-care instruments do not meet generally accepted analytical performance criteria.
    Lenters-Westra E; Slingerland RJ
    Clin Chem; 2014 Aug; 60(8):1062-72. PubMed ID: 24865164
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Verification of point-of-care analysers for C-reactive protein, lipid studies and glycated haemoglobin.
    Li B; Kumar A; Finlay C; van Drimmelen M; Barnes E; Southby S; Florkowski C
    Pathology; 2023 Dec; 55(7):989-999. PubMed ID: 37778963
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Long-Term Performance of Point-of-Care Hemoglobin A1c Assays.
    Paknikar S; Sarmah R; Sivaganeshan L; Welke A; Rizzo A; Larson K; Rendell M
    J Diabetes Sci Technol; 2016 Nov; 10(6):1308-1315. PubMed ID: 27113451
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.