21. Microbial contamination of dialysate and its prevention in haemodialysis units. Oie S; Kamiya A; Yoneda I; Uchiyama K; Tsuchida M; Takai K; Naito K J Hosp Infect; 2003 Jun; 54(2):115-9. PubMed ID: 12818584 [TBL] [Abstract][Full Text] [Related]
22. [The level of endotoxins in hemodialysis water and dialysate]. Skarupskiene I; Bumblyte IA; Kuzminskis V Medicina (Kaunas); 2007; 43 Suppl 1():81-4. PubMed ID: 17551282 [TBL] [Abstract][Full Text] [Related]
23. Microbiology of water and fluids for hemodialysis. Nystrand R J Chin Med Assoc; 2008 May; 71(5):223-9. PubMed ID: 18490224 [TBL] [Abstract][Full Text] [Related]
24. Delftia acidovorans pseudo outbreak in portable reverse osmosis machines: Interventions to ensure safe and cost-effective hemodialysis. Yassin MH; Abramovitz B; Hariri R; McKibben L; Pinevich AJ Am J Infect Control; 2020 Mar; 48(3):304-308. PubMed ID: 31952870 [TBL] [Abstract][Full Text] [Related]
25. Microbial and endotoxin contamination in water and dialysate in the central United States. Klein E; Pass T; Harding GB; Wright R; Million C Artif Organs; 1990 Apr; 14(2):85-94. PubMed ID: 2350260 [TBL] [Abstract][Full Text] [Related]
26. Quality of water used for haemodialysis: bacteriological and chemical parameters. Vorbeck-Meister I; Sommer R; Vorbeck F; Hörl WH Nephrol Dial Transplant; 1999 Mar; 14(3):666-75. PubMed ID: 10193817 [TBL] [Abstract][Full Text] [Related]
27. Defining the microbiological quality of dialysis fluid. Ledebo I; Nystrand R Artif Organs; 1999 Jan; 23(1):37-43. PubMed ID: 9950177 [TBL] [Abstract][Full Text] [Related]
28. Endoscopy supply water and final rinse testing: five years of experience. Marek A; Smith A; Peat M; Connell A; Gillespie I; Morrison P; Hamilton A; Shaw D; Stewart A; Hamilton K; Smith I; Mead A; Howard P; Ingle D J Hosp Infect; 2014 Dec; 88(4):207-12. PubMed ID: 25308933 [TBL] [Abstract][Full Text] [Related]
29. Quality of hemodialysis water: a 7-year multicenter study. Laurence RA; Lapierre ST Am J Kidney Dis; 1995 May; 25(5):738-50. PubMed ID: 7747728 [TBL] [Abstract][Full Text] [Related]
30. Water treatment and monitor disinfection. Cappelli G; Riccardi M; Perrone S; Bondi M; Ligabue G; Albertazzi A Hemodial Int; 2006 Jan; 10 Suppl 1():S13-8. PubMed ID: 16441861 [TBL] [Abstract][Full Text] [Related]
31. Prevent infection linked to the dialysis water in a hemodialysis center in Fez city (Morocco). Oumokhtar B; Lalami Ael O; Mahmoud M; Berrada S; Arrayhani M; Houssaini TS Pan Afr Med J; 2013; 16():122. PubMed ID: 24839530 [TBL] [Abstract][Full Text] [Related]
32. Assessment of the extent of bacterial growth in reverse osmosis system for improving drinking water quality. Park SK; Hu JY J Environ Sci Health A Tox Hazard Subst Environ Eng; 2010; 45(8):968-77. PubMed ID: 20512722 [TBL] [Abstract][Full Text] [Related]
33. Pyrogenic reactions in patients receiving conventional, high-efficiency, or high-flux hemodialysis treatments with bicarbonate dialysate containing high concentrations of bacteria and endotoxin. Gordon SM; Oettinger CW; Bland LA; Oliver JC; Arduino MJ; Aguero SM; McAllister SK; Favero MS; Jarvis WR J Am Soc Nephrol; 1992 Mar; 2(9):1436-44. PubMed ID: 1627766 [TBL] [Abstract][Full Text] [Related]
34. Effectiveness of various chemical disinfectants versus cleaning combined with heat disinfection on Pseudomonas biofilm in hemodialysis machines. Holmes CJ; Degremont A; Kubey W; Straka P; Man NK Blood Purif; 2004; 22(5):461-8. PubMed ID: 15359105 [TBL] [Abstract][Full Text] [Related]
35. Dialysis fluid contamination of pathways and life of microbes. Nystrand R EDTNA ERCA J; 2001; 27(3):135-9. PubMed ID: 11868995 [TBL] [Abstract][Full Text] [Related]
37. [Maintenance and monitoring of water treatment system]. Pontoriero G; Pozzoni P; Tentori F; Scaravilli P; Locatelli F G Ital Nefrol; 2005; 22(6):562-8. PubMed ID: 16342048 [TBL] [Abstract][Full Text] [Related]
38. An easy disinfection strategy for pipes connecting hemodialysis equipment. Tagaya M; Oda Y; Kimura A; Irifune R; Okano S; Murataka T; Handa H; Takahashi S Int J Artif Organs; 2021 Jun; 44(6):385-392. PubMed ID: 33222595 [TBL] [Abstract][Full Text] [Related]
39. A 5 year longitudinal study of water quality for final rinsing in the single chamber washer-disinfector with a reverse osmosis plant. Uetera Y; Kishii K; Yasuhara H; Kumada N; Moriya K; Saito R; Okazaki M; Misawa Y; Kawamura K PDA J Pharm Sci Technol; 2013; 67(4):399-411. PubMed ID: 23872448 [TBL] [Abstract][Full Text] [Related]
40. Persistence of microflora in biofilm within fluid pathways of contemporary haemodialysis monitors (Gambro AK-10). Phillips G; Hudson S; Stewart WK J Hosp Infect; 1994 Jun; 27(2):117-25. PubMed ID: 7930538 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]