189 related articles for article (PubMed ID: 24726423)
1. Device thrombosis in continuous-flow left ventricular assist devices: a new manifestation of Kounis syndrome?
Kounis NG; Soufras GD; Davlouros P
J Heart Lung Transplant; 2014 Jun; 33(6):665. PubMed ID: 24726423
[No Abstract] [Full Text] [Related]
2. Device thrombosis in HeartMate II continuous-flow left ventricular assist devices: a multifactorial phenomenon.
Uriel N; Han J; Morrison KA; Nahumi N; Yuzefpolskaya M; Garan AR; Duong J; Colombo PC; Takayama H; Thomas S; Naka Y; Jorde UP
J Heart Lung Transplant; 2014 Jan; 33(1):51-9. PubMed ID: 24290832
[TBL] [Abstract][Full Text] [Related]
3. Incidence of increases in pump power use and associated clinical outcomes with an axial continuous-flow ventricular assist device.
Steffen RJ; Soltesz EG; Miracle K; Lee S; Mountis M; Moazami N
J Heart Lung Transplant; 2014 Jan; 33(1):105-6. PubMed ID: 24418736
[No Abstract] [Full Text] [Related]
4. Diagnosis of hemolysis and device thrombosis with lactate dehydrogenase during left ventricular assist device support.
Shah P; Mehta VM; Cowger JA; Aaronson KD; Pagani FD
J Heart Lung Transplant; 2014 Jan; 33(1):102-4. PubMed ID: 23968811
[No Abstract] [Full Text] [Related]
5. Continuous flow left ventricular assist device related aortic root thrombosis complicated by left main coronary artery occlusion.
Shah S; Mehra MR; Couper GS; Desai AS
J Heart Lung Transplant; 2014 Jan; 33(1):119-20. PubMed ID: 24418738
[No Abstract] [Full Text] [Related]
6. Uncommon Cause of Hemolysis With Rapid Decrease in Mechanical Circulatory Support Flow.
Nordan T; Ortoleva J; Chen FY; Kapur NK; Couper GS; Kawabori M
Circ Heart Fail; 2021 Jan; 14(1):e007312. PubMed ID: 33435696
[No Abstract] [Full Text] [Related]
7. Aortic valve opening and thrombotic events with continuous-flow left ventricular assist devices.
Saeed O; Maybaum S; Alessandro DD; Goldstein DJ; Patel SR
J Heart Lung Transplant; 2014 Jan; 33(1):109-12. PubMed ID: 23937883
[No Abstract] [Full Text] [Related]
8. Hemolysis: a harbinger of adverse outcome after left ventricular assist device implant.
Cowger JA; Romano MA; Shah P; Shah N; Mehta V; Haft JW; Aaronson KD; Pagani FD
J Heart Lung Transplant; 2014 Jan; 33(1):35-43. PubMed ID: 24418732
[TBL] [Abstract][Full Text] [Related]
9. The use of eptifibatide for suspected pump thrombus or thrombosis in patients with left ventricular assist devices.
Tellor BR; Smith JR; Prasad SM; Joseph SM; Silvestry SC
J Heart Lung Transplant; 2014 Jan; 33(1):94-101. PubMed ID: 24418735
[TBL] [Abstract][Full Text] [Related]
10. Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) analysis of pump thrombosis in the HeartMate II left ventricular assist device.
Kirklin JK; Naftel DC; Kormos RL; Pagani FD; Myers SL; Stevenson LW; Acker MA; Goldstein DL; Silvestry SC; Milano CA; Baldwin JT; Pinney S; Eduardo Rame J; Miller MA
J Heart Lung Transplant; 2014 Jan; 33(1):12-22. PubMed ID: 24418730
[TBL] [Abstract][Full Text] [Related]
11. A novel link between G6PD deficiency and hemolysis in patients with continuous-flow left ventricular assist devices.
Alhosaini H; Jensen BC; Chang PP; Sheridan BC; Katz JN
J Heart Lung Transplant; 2014 Jan; 33(1):116-7. PubMed ID: 24290168
[No Abstract] [Full Text] [Related]
12. Hemolysis in left ventricular assist device: a retrospective analysis of outcomes.
Ravichandran AK; Parker J; Novak E; Joseph SM; Schilling JD; Ewald GA; Silvestry S
J Heart Lung Transplant; 2014 Jan; 33(1):44-50. PubMed ID: 24418733
[TBL] [Abstract][Full Text] [Related]
13. Carotid-bulb thrombus and continuous-flow left ventricular assist devices: a novel observation.
Reul JT; Reul GJ; Frazier OH
J Heart Lung Transplant; 2014 Jan; 33(1):107-9. PubMed ID: 24290833
[No Abstract] [Full Text] [Related]
14. Increase in left ventricular assist device thrombosis.
Goldstein D; John R; Salerno C
N Engl J Med; 2014 Apr; 370(15):1465. PubMed ID: 24716698
[No Abstract] [Full Text] [Related]
15. Increase in left ventricular assist device thrombosis.
Frazier OH
N Engl J Med; 2014 Apr; 370(15):1464-5. PubMed ID: 24716697
[No Abstract] [Full Text] [Related]
16. Increase in left ventricular assist device thrombosis.
Hoefer D; Velik-Salchner C; Antretter H
N Engl J Med; 2014 Apr; 370(15):1464. PubMed ID: 24716696
[No Abstract] [Full Text] [Related]
17. Increase in left ventricular assist device thrombosis.
Schmitto JD; Avsar M; Haverich A
N Engl J Med; 2014 Apr; 370(15):1463-4. PubMed ID: 24716695
[No Abstract] [Full Text] [Related]
18. Increase in left ventricular assist device thrombosis.
Starling RC; Blackstone EH; Smedira NG
N Engl J Med; 2014 Apr; 370(15):1465-6. PubMed ID: 24716694
[No Abstract] [Full Text] [Related]
19. Discriminatory performance of positive urine hemoglobin for detection of significant hemolysis in patients with continuous-flow left ventricular assist devices.
Gavalas MV; Breskin A; Yuzefpolskaya M; Eisenberger A; Castagna F; Demmer RT; Flannery M; Garan AR; Takeda K; Takayama H; Naka Y; Topkara VK; Colombo PC
J Heart Lung Transplant; 2017 Jan; 36(1):59-63. PubMed ID: 27773451
[TBL] [Abstract][Full Text] [Related]
20. Device Management and Flow Optimization on Left Ventricular Assist Device Support.
Tchoukina I; Smallfield MC; Shah KB
Crit Care Clin; 2018 Jul; 34(3):453-463. PubMed ID: 29907276
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]