These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
472 related articles for article (PubMed ID: 24726588)
1. A correlation between bone (B), insertion torque (IT), and implant stability (S): BITS score. Herekar M; Sethi M; Ahmad T; Fernandes AS; Patil V; Kulkarni H J Prosthet Dent; 2014 Oct; 112(4):805-10. PubMed ID: 24726588 [TBL] [Abstract][Full Text] [Related]
2. Relationships between bone density values from cone beam computed tomography, maximum insertion torque, and resonance frequency analysis at implant placement: a pilot study. Fuster-Torres MÁ; Peñarrocha-Diago M; Peñarrocha-Oltra D; Peñarrocha-Diago M Int J Oral Maxillofac Implants; 2011; 26(5):1051-6. PubMed ID: 22010089 [TBL] [Abstract][Full Text] [Related]
3. Undersized implant site preparation to enhance primary implant stability in poor bone density: a prospective clinical study. Alghamdi H; Anand PS; Anil S J Oral Maxillofac Surg; 2011 Dec; 69(12):e506-12. PubMed ID: 22117707 [TBL] [Abstract][Full Text] [Related]
5. Two alternative surgical techniques for enhancing primary implant stability in the posterior maxilla: a clinical study including bone density, insertion torque, and resonance frequency analysis data. Turkyilmaz I; Aksoy U; McGlumphy EA Clin Implant Dent Relat Res; 2008 Dec; 10(4):231-7. PubMed ID: 18384409 [TBL] [Abstract][Full Text] [Related]
6. Implant primary stability determined by resonance frequency analysis: correlation with insertion torque, histologic bone volume, and torsional stability at 6 weeks. Makary C; Rebaudi A; Sammartino G; Naaman N Implant Dent; 2012 Dec; 21(6):474-80. PubMed ID: 23149504 [TBL] [Abstract][Full Text] [Related]
7. Assessment of the correlation between insertion torque and resonance frequency analysis of implants placed in bone tissue of different densities. Filho LC; Cirano FR; Hayashi F; Feng HS; Conte A; Dib LL; Casati MZ J Oral Implantol; 2014 Jun; 40(3):259-62. PubMed ID: 24914911 [TBL] [Abstract][Full Text] [Related]
8. Primary stability determination by means of insertion torque and RFA in a sample of 4,135 implants. Degidi M; Daprile G; Piattelli A Clin Implant Dent Relat Res; 2012 Aug; 14(4):501-7. PubMed ID: 20849539 [TBL] [Abstract][Full Text] [Related]
9. Correlation Between Implant Geometry, Implant Surface, Insertion Torque, and Primary Stability: In Vitro Biomechanical Analysis. Falco A; Berardini M; Trisi P Int J Oral Maxillofac Implants; 2018; 33(4):824-830. PubMed ID: 30024998 [TBL] [Abstract][Full Text] [Related]
10. Sensitivity of resonance frequency analysis method to assess implant stability. Turkyilmaz I; Company AM N Y State Dent J; 2011; 77(5):44-9. PubMed ID: 22029115 [TBL] [Abstract][Full Text] [Related]
11. Relationship between the bone density estimated by cone-beam computed tomography and the primary stability of dental implants. Isoda K; Ayukawa Y; Tsukiyama Y; Sogo M; Matsushita Y; Koyano K Clin Oral Implants Res; 2012 Jul; 23(7):832-6. PubMed ID: 21545533 [TBL] [Abstract][Full Text] [Related]
12. Peak insertion torque correlated to histologically and clinically evaluated bone density. Makary C; Rebaudi A; Mokbel N; Naaman N Implant Dent; 2011 Jun; 20(3):182-91. PubMed ID: 21613945 [TBL] [Abstract][Full Text] [Related]
13. Differences in implant stability associated with various methods of preparation of the implant bed: an in vitro study. Ahn SJ; Leesungbok R; Lee SW; Heo YK; Kang KL J Prosthet Dent; 2012 Jun; 107(6):366-72. PubMed ID: 22633592 [TBL] [Abstract][Full Text] [Related]
14. Influence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: a human cadaver study. Turkyilmaz I; Sennerby L; Yilmaz B; Bilecenoglu B; Ozbek EN Clin Implant Dent Relat Res; 2009 Mar; 11(1):52-8. PubMed ID: 18384400 [TBL] [Abstract][Full Text] [Related]
15. Determination of primary stability: a comparison of the surgeon's perception and objective measurements. Degidi M; Daprile G; Piattelli A Int J Oral Maxillofac Implants; 2010; 25(3):558-61. PubMed ID: 20556255 [TBL] [Abstract][Full Text] [Related]
16. Clinical study on the primary stability of two dental implant systems with resonance frequency analysis. Rabel A; Köhler SG; Schmidt-Westhausen AM Clin Oral Investig; 2007 Sep; 11(3):257-65. PubMed ID: 17401588 [TBL] [Abstract][Full Text] [Related]
17. Relations between the bone density values from computerized tomography, and implant stability parameters: a clinical study of 230 regular platform implants. Turkyilmaz I; Tumer C; Ozbek EN; Tözüm TF J Clin Periodontol; 2007 Aug; 34(8):716-22. PubMed ID: 17635248 [TBL] [Abstract][Full Text] [Related]
18. Evaluation of relationship between preoperative bone density values derived from cone beam computed tomography and implant stability parameters: a clinical study. Salimov F; Tatli U; Kürkçü M; Akoğlan M; Oztunç H; Kurtoğlu C Clin Oral Implants Res; 2014 Sep; 25(9):1016-21. PubMed ID: 23772811 [TBL] [Abstract][Full Text] [Related]
19. Influence of the surgical technique and surface roughness on the primary stability of an implant in artificial bone with a density equivalent to maxillary bone: a laboratory study. Tabassum A; Meijer GJ; Wolke JG; Jansen JA Clin Oral Implants Res; 2009 Apr; 20(4):327-32. PubMed ID: 19298286 [TBL] [Abstract][Full Text] [Related]
20. The relationship between implant stability quotient values and implant insertion variables: a clinical study. Park KJ; Kwon JY; Kim SK; Heo SJ; Koak JY; Lee JH; Lee SJ; Kim TH; Kim MJ J Oral Rehabil; 2012 Feb; 39(2):151-9. PubMed ID: 21923718 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]