These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

235 related articles for article (PubMed ID: 24726800)

  • 41. In vivo attenuation and equivalent scatterer size parameters for atherosclerotic carotid plaque: preliminary results.
    Shi H; Varghese T; Mitchell CC; McCormick M; Dempsey RJ; Kliewer MA
    Ultrasonics; 2009 Dec; 49(8):779-85. PubMed ID: 19640556
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Robust Scatterer Number Density Segmentation of Ultrasound Images.
    Tehrani AKZ; Rosado-Mendez IM; Rivaz H
    IEEE Trans Ultrason Ferroelectr Freq Control; 2022 Apr; 69(4):1169-1180. PubMed ID: 35044911
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Performance evaluation of the spectral centroid downshift method for attenuation estimation.
    Samimi K; Varghese T
    IEEE Trans Ultrason Ferroelectr Freq Control; 2015 May; 62(5):871-80. PubMed ID: 25965681
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Reference characterisation of sound speed and attenuation of the IEC agar-based tissue-mimicking material up to a frequency of 60 MHz.
    Rajagopal S; Sadhoo N; Zeqiri B
    Ultrasound Med Biol; 2015 Jan; 41(1):317-33. PubMed ID: 25220268
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Model-based phase velocity and attenuation estimation in wideband ultrasonic measurement systems.
    Martinsson J; Carlson JE; Niemi J
    IEEE Trans Ultrason Ferroelectr Freq Control; 2007 Jan; 54(1):138-46. PubMed ID: 17225808
    [TBL] [Abstract][Full Text] [Related]  

  • 46. A novel coded excitation scheme to improve spatial and contrast resolution of quantitative ultrasound imaging.
    Sanchez JR; Pocci D; Oelze ML
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Oct; 56(10):2111-23. PubMed ID: 19942499
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Attenuation Coefficient Estimation of Normal Placentas.
    Deeba F; Ma M; Pesteie M; Terry J; Pugash D; Hutcheon JA; Mayer C; Salcudean S; Rohling R
    Ultrasound Med Biol; 2019 May; 45(5):1081-1093. PubMed ID: 30685076
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Ultrasound attenuation measurements of the liver in vivo using a commercial sector scanner.
    Garra BS; Shawker TH; Nassi M; Russell MA
    Ultrason Imaging; 1984 Oct; 6(4):396-407. PubMed ID: 6399170
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Mechanisms for attenuation in cancellous-bone-mimicking phantoms.
    Wear KA
    IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Nov; 55(11):2418-25. PubMed ID: 19049921
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Study of ultrasound stiffness imaging methods using tissue mimicking phantoms.
    Manickam K; Machireddy RR; Seshadri S
    Ultrasonics; 2014 Feb; 54(2):621-31. PubMed ID: 24083832
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Statistics of boundaries in ultrasonic B-scan images.
    Shankar PM
    Ultrasound Med Biol; 2015 Jan; 41(1):268-80. PubMed ID: 25438836
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Acoustic backscatter and effective scatterer size estimates using a 2D CMUT transducer.
    Liu W; Zagzebski JA; Hall TJ; Madsen EL; Varghese T; Kliewer MA; Panda S; Lowery C; Barnes S
    Phys Med Biol; 2008 Aug; 53(15):4169-83. PubMed ID: 18635893
    [TBL] [Abstract][Full Text] [Related]  

  • 53. The use of the compound probability density function in ultrasonic tissue characterization.
    Shankar PM
    Phys Med Biol; 2004 Mar; 49(6):1007-15. PubMed ID: 15104323
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Estimating the total ultrasound attenuation along the propagation path by applying multiple filters to backscattered echoes from a single spherically focused source.
    Bigelow T
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Apr; 57(4):900-7. PubMed ID: 20378452
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Estimation of Backscatter Coefficients Using an In Situ Calibration Source.
    Nguyen TN; Tam AJ; Do MN; Oelze ML
    IEEE Trans Ultrason Ferroelectr Freq Control; 2020 Feb; 67(2):308-317. PubMed ID: 31567079
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Statistics of ultrasonic scatterer size estimation with a reference phantom.
    Gerig A; Zagzebski J; Varghese T
    J Acoust Soc Am; 2003 Jun; 113(6):3430-7. PubMed ID: 12822813
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Lower Bound on Estimation Variance of the Ultrasonic Attenuation Coefficient Using the Spectral-Difference Reference-phantom Method.
    Samimi K; Varghese T
    Ultrason Imaging; 2017 May; 39(3):151-171. PubMed ID: 28425388
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Computer-aided B-mode ultrasound diagnosis of hepatic steatosis: a feasibility study.
    Thijssen JM; Starke A; Weijers G; Haudum A; Herzog K; Wohlsein P; Rehage J; De Korte CL
    IEEE Trans Ultrason Ferroelectr Freq Control; 2008; 55(6):1343-54. PubMed ID: 18599422
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Overdetermined least-squares aberration estimates using common-midpoint signals.
    Haun MA; Jones DL; O'Brien WD
    IEEE Trans Med Imaging; 2004 Oct; 23(10):1205-20. PubMed ID: 15493689
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Impact of local attenuation approximations when estimating correlation length from backscattered ultrasound echoes.
    Bigelow TA; O'Brien WD
    J Acoust Soc Am; 2006 Jul; 120(1):546-53. PubMed ID: 16875251
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.