BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

352 related articles for article (PubMed ID: 24739791)

  • 1. Accuracy of patient-specific guided glenoid baseplate positioning for reverse shoulder arthroplasty.
    Levy JC; Everding NG; Frankle MA; Keppler LJ
    J Shoulder Elbow Surg; 2014 Oct; 23(10):1563-7. PubMed ID: 24739791
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparing conventional and computer-assisted surgery baseplate and screw placement in reverse shoulder arthroplasty.
    Venne G; Rasquinha BJ; Pichora D; Ellis RE; Bicknell R
    J Shoulder Elbow Surg; 2015 Jul; 24(7):1112-9. PubMed ID: 25556807
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Three-dimensional planning and use of patient-specific guides improve glenoid component position: an in vitro study.
    Walch G; Vezeridis PS; Boileau P; Deransart P; Chaoui J
    J Shoulder Elbow Surg; 2015 Feb; 24(2):302-9. PubMed ID: 25183662
    [TBL] [Abstract][Full Text] [Related]  

  • 4. 3D navigated implantation of the glenoid component in reversed shoulder arthroplasty. Feasibility and results in an anatomic study.
    Stübig T; Petri M; Zeckey C; Hawi N; Krettek C; Citak M; Meller R
    Int J Med Robot; 2013 Dec; 9(4):480-5. PubMed ID: 23908109
    [TBL] [Abstract][Full Text] [Related]  

  • 5. 3-dimensionally printed patient-specific glenoid drill guides vs. standard nonspecific instrumentation: a randomized controlled trial comparing the accuracy of glenoid component placement in anatomic total shoulder arthroplasty.
    Dasari SP; Menendez ME; Espinoza Orias A; Khan ZA; Vadhera AS; Ebersole JW; White GM; Forsythe B; Cole BJ; Nicholson GP; Garrigues GE; Verma NN
    J Shoulder Elbow Surg; 2024 Feb; 33(2):223-233. PubMed ID: 37774830
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Preoperative planning for accurate glenoid component positioning in reverse shoulder arthroplasty.
    Berhouet J; Gulotta LV; Dines DM; Craig E; Warren RF; Choi D; Chen X; Kontaxis A
    Orthop Traumatol Surg Res; 2017 May; 103(3):407-413. PubMed ID: 28238965
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Validation of mixed-reality surgical navigation for glenoid axis pin placement in shoulder arthroplasty using a cadaveric model.
    Sanchez-Sotelo J; Berhouet J; Chaoui J; Freehill MT; Collin P; Warner J; Walch G; Athwal GS
    J Shoulder Elbow Surg; 2024 May; 33(5):1177-1184. PubMed ID: 37890765
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Design and development of a computer assisted glenoid implantation technique for shoulder replacement surgery.
    Nguyen D; Ferreira LM; Brownhill JR; Faber KJ; Johnson JA
    Comput Aided Surg; 2007 May; 12(3):152-9. PubMed ID: 17538787
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accuracy of patient-specific guided implantation of the glenoid component in reversed shoulder arthroplasty.
    Verborgt O; Hachem AI; Eid K; Vuylsteke K; Ferrand M; Hardy P
    Orthop Traumatol Surg Res; 2018 Oct; 104(6):767-772. PubMed ID: 29505820
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Three dimensional patient-specific guides for guide pin positioning in reverse shoulder arthroplasty: An experimental study on different glenoid types.
    Mohammad Sadeghi M; Kececi EF; Kapicioglu M; Aralasmak A; Tezgel O; Basaran MA; Yildiz F; Bilsel K
    J Orthop Surg (Hong Kong); 2022; 30(1):10225536221079432. PubMed ID: 35220811
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Three-dimensional preoperative planning software and a novel information transfer technology improve glenoid component positioning.
    Iannotti J; Baker J; Rodriguez E; Brems J; Ricchetti E; Mesiha M; Bryan J
    J Bone Joint Surg Am; 2014 May; 96(9):e71. PubMed ID: 24806017
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Testing of a novel pin array guide for accurate three-dimensional glenoid component positioning.
    Lewis GS; Stevens NM; Armstrong AD
    J Shoulder Elbow Surg; 2015 Dec; 24(12):1939-47. PubMed ID: 26256017
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Accuracy of placement of the glenoid component in reversed shoulder arthroplasty with and without navigation.
    Verborgt O; De Smedt T; Vanhees M; Clockaerts S; Parizel PM; Van Glabbeek F
    J Shoulder Elbow Surg; 2011 Jan; 20(1):21-6. PubMed ID: 21134663
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of the Subchondral Smile and Surface Referencing Techniques in Reverse Shoulder Arthroplasty.
    Dilisio MF; Warner JJ; Walch G
    Orthopedics; 2016 Jul; 39(4):e615-20. PubMed ID: 27322170
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of Preoperative Implant Placement in Total Shoulder Arthroplasty.
    Hamilton MA; Polakovic S; Saadi P; Jones RB; Parsons IM; Cheung EV
    Bull Hosp Jt Dis (2013); 2015 Dec; 73 Suppl 1():S47-51. PubMed ID: 26631196
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High intraoperative accuracy and low complication rate of computer-assisted navigation of the glenoid in total shoulder arthroplasty.
    Larose G; Greene AT; Jung A; Polakovic SV; Davis NZ; Zuckerman JD; Virk MS
    J Shoulder Elbow Surg; 2023 Jun; 32(6S):S39-S45. PubMed ID: 36681107
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Patient-specific targeting guides compared with traditional instrumentation for glenoid component placement in shoulder arthroplasty: a multi-surgeon study in 70 arthritic cadaver specimens.
    Throckmorton TW; Gulotta LV; Bonnarens FO; Wright SA; Hartzell JL; Rozzi WB; Hurst JM; Frostick SP; Sperling JW
    J Shoulder Elbow Surg; 2015 Jun; 24(6):965-71. PubMed ID: 25535020
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Computer navigation leads to more accurate glenoid targeting during total shoulder arthroplasty compared with 3-dimensional preoperative planning alone.
    Schoch BS; Haupt E; Leonor T; Farmer KW; Wright TW; King JJ
    J Shoulder Elbow Surg; 2020 Nov; 29(11):2257-2263. PubMed ID: 32586595
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The Value of Computer-Assisted Navigation for Glenoid Baseplate Implantation in Reverse Shoulder Arthroplasty: A Systematic Review and Meta-Analysis.
    Velasquez Garcia A; Abdo G; Sanchez-Sotelo J; Morrey ME
    JBJS Rev; 2023 Aug; 11(8):. PubMed ID: 37616447
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Novel robotic technology for the rapid intraoperative manufacture of patient-specific instrumentation allowing for improved glenoid component accuracy in shoulder arthroplasty: a cadaveric study.
    Darwood A; Hurst SA; Villatte G; Tatti F; El Daou H; Reilly P; Rodriguez Y Baena F; Majed A; Emery R
    J Shoulder Elbow Surg; 2022 Mar; 31(3):561-570. PubMed ID: 34624464
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.