These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
123 related articles for article (PubMed ID: 2474489)
21. Absorption characteristics of human fetal hemoglobin at wavelengths used in pulse oximetry. Harris AP; Sendak MJ; Donham RT; Thomas M; Duncan D J Clin Monit; 1988 Jul; 4(3):175-7. PubMed ID: 2463343 [TBL] [Abstract][Full Text] [Related]
22. Correlation of fetal oxygen saturation to fetal heart rate patterns. Evaluation of fetal pulse oximetry with two different oxisensors. Luttkus AK; Friedmann W; Homm-Luttkus C; Dudenhausen JW Acta Obstet Gynecol Scand; 1998 Mar; 77(3):307-12. PubMed ID: 9539277 [TBL] [Abstract][Full Text] [Related]
23. Meconium-stained amniotic fluid and fetal oxygen saturation measured by pulse oximetry during labour. Grignaffini A; Soncini E; Ronzoni E; Piazza E; Anfuso S; Vadora E Acta Biomed; 2004; 75 Suppl 1():45-52. PubMed ID: 15301290 [TBL] [Abstract][Full Text] [Related]
24. Reflectance pulse oximetry from core body in neonates and infants: comparison to arterial blood oxygen saturation and to transmission pulse oximetry. Kugelman A; Wasserman Y; Mor F; Goldinov L; Geller Y; Bader D J Perinatol; 2004 Jun; 24(6):366-71. PubMed ID: 15057251 [TBL] [Abstract][Full Text] [Related]
25. Pulse oximetry in children with congenital heart disease: effects of cardiopulmonary bypass and cyanosis. Torres A; Skender KM; Wohrley JD; Aldag JC; Raff GW; Bysani GK; Geiss DM J Intensive Care Med; 2004; 19(4):229-34. PubMed ID: 15296623 [TBL] [Abstract][Full Text] [Related]
28. Pulse oximetry for continuous oxygen monitoring in sick newborn infants. Durand M; Ramanathan R J Pediatr; 1986 Dec; 109(6):1052-6. PubMed ID: 2431130 [TBL] [Abstract][Full Text] [Related]
29. Maternal cigarette smoking and fetal oxygen transport: a study of P50, 2,3-diphosphoglycerate, total hemoglobin, hematocrit, and type F hemoglobin in fetal blood. Bureau MA; Shapcott D; Berthiaume Y; Monette J; Blouin D; Blanchard P; Begin R Pediatrics; 1983 Jul; 72(1):22-6. PubMed ID: 6191270 [TBL] [Abstract][Full Text] [Related]
30. Notes on the apparent discordance of pulse oximetry and multi-wavelength haemoglobin photometry. Nijland R; Jongsma HW; Nijhuis JG; Oeseburg B; Zijlstra WG Acta Anaesthesiol Scand Suppl; 1995; 107():49-52. PubMed ID: 8599297 [TBL] [Abstract][Full Text] [Related]
31. Accuracy of pulse oximetry during arterial oxyhemoglobin desaturation in dogs. Sendak MJ; Harris AP; Donham RT Anesthesiology; 1988 Jan; 68(1):111-4. PubMed ID: 3337361 [TBL] [Abstract][Full Text] [Related]
32. In vivo oxygen dissociation curves in transfused and untransfused newborns with cardiopulmonary disease. Wilkinson AR; Phibbs RH; Heilbron DC; Gregory GA; Versmold HT Am Rev Respir Dis; 1980 Oct; 122(4):629-34. PubMed ID: 6159811 [TBL] [Abstract][Full Text] [Related]
33. Absorption spectra of human fetal and adult oxyhemoglobin, de-oxyhemoglobin, carboxyhemoglobin, and methemoglobin. Zijlstra WG; Buursma A; Meeuwsen-van der Roest WP Clin Chem; 1991 Sep; 37(9):1633-8. PubMed ID: 1716537 [TBL] [Abstract][Full Text] [Related]
34. The measurement of accurate fetal hemoglobin and related oxygen saturation by the hemoximeter. Shiao SY; Ou CN; Pierantoni H Clin Chim Acta; 2006 Dec; 374(1-2):75-80. PubMed ID: 16844104 [TBL] [Abstract][Full Text] [Related]
35. The accuracy of pulse oximetry in neonates: effects of fetal hemoglobin and bilirubin. Anderson JV J Perinatol; 1987; 7(4):323. PubMed ID: 2463346 [No Abstract] [Full Text] [Related]