BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

162 related articles for article (PubMed ID: 24747107)

  • 1. Clinical implications of elevated HIV-1 viral load results obtained from samples stored frozen in vacutainer plasma preparation tubes.
    Cloherty G; Swanson P; Lucic D; Dieckhaus K; Anthony P; Cataline P; Herman C; Hackett J; Skolnik PR; Chirch L
    J Virol Methods; 2014 Aug; 204():91-2. PubMed ID: 24747107
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Initial evaluation of the Roche COBAS TaqMan HIV-1 v2.0 assay for determining viral load in HIV-infected individuals.
    Taylor N; Schmid I; Egle A; Greil R; Patsch W; Oberkofler H
    Antivir Ther; 2009; 14(8):1189-93. PubMed ID: 20032549
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison between the automated Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test version 2.0 assay and its version 1 and Nuclisens HIV-1 EasyQ version 2.0 assays when measuring diverse HIV-1 genotypes in China.
    Xu S; Song A; Nie J; Li X; Meng S; Zhang C; Wang Y
    J Clin Virol; 2012 Jan; 53(1):33-7. PubMed ID: 22051503
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of the use of plasma preparation tubes for HIV viral load testing on the COBAS AmpliPrep/COBAS TaqMan HIV-1 version 2.0.
    Goedhals D; Scott LE; Moretti S; Cooper MA; Opperman WJ; Rossouw I
    J Virol Methods; 2013 Feb; 187(2):248-50. PubMed ID: 23178587
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Validation of dilution of plasma samples with phosphate buffered saline to eliminate the problem of small volumes associated with children infected with HIV-1 for viral load testing using Cobas AmpliPrep/COBAS TaqMan HIV-1 test, version 2.0 (CAP CTM HIV v2.0).
    Mine M; Nkoane T; Sebetso G; Sakyi B; Makhaola K; Gaolathe T
    J Virol Methods; 2013 Dec; 194(1-2):217-21. PubMed ID: 24025342
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Performance evaluation of the COBAS/TaqMan HIV-1 v2.0 in HIV-1 positive patients with low viral load: a comparative study.
    Paba P; Fabeni L; Ciccozzi M; Perno CF; Ciotti M
    J Virol Methods; 2011 May; 173(2):399-402. PubMed ID: 21419171
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Discordance between viral loads determined by Roche COBAS AMPLICOR human immunodeficiency virus type 1 monitor (version 1.5) Standard and ultrasensitive assays caused by freezing patient plasma in centrifuged becton-dickinson vacutainer brand plasma preparation tubes.
    Salimnia H; Moore EC; Crane LR; Macarthur RD; Fairfax MR
    J Clin Microbiol; 2005 Sep; 43(9):4635-9. PubMed ID: 16145119
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Performance evaluation of the new Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test version 2.0 for quantification of human immunodeficiency virus type 1 RNA.
    Pas S; Rossen JW; Schoener D; Thamke D; Pettersson A; Babiel R; Schutten M
    J Clin Microbiol; 2010 Apr; 48(4):1195-200. PubMed ID: 20164281
    [TBL] [Abstract][Full Text] [Related]  

  • 9. HIV-1 variability and viral load technique could lead to false positive HIV-1 detection and to erroneous viral quantification in infected specimens.
    Alvarez P; Martín L; Prieto L; Obiang J; Vargas A; Avedillo P; Rojo P; Fernández McPhee C; Benito A; Ramos JT; Holguín Á
    J Infect; 2015 Sep; 71(3):368-76. PubMed ID: 26033694
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test version 2.0 (CAP/CTM v2.0) with other real-time PCR assays in HIV-1 monitoring and follow-up of low-level viral loads.
    Wojewoda CM; Spahlinger T; Harmon ML; Schnellinger B; Li Q; Dejelo C; Schmotzer C; Zhou L
    J Virol Methods; 2013 Jan; 187(1):1-5. PubMed ID: 23098667
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Elevation of viral load by PCR and use of plasma preparation tubes for quantification of human immunodeficiency virus type 1.
    García-Bujalance S; Ladrón de Guevara C; González-García J; Arribas JR; Zamora F; Gutiérrez A
    J Microbiol Methods; 2007 May; 69(2):384-6. PubMed ID: 17363096
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 test v1.0 with v2.0 in HIV-1 viral load quantification.
    Tung YC; Ke LY; Lu PL; Lin KH; Lee SC; Lin YY; Chou LC; Tsai WC
    Kaohsiung J Med Sci; 2015 Apr; 31(4):188-93. PubMed ID: 25835274
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparative RNA quantification of HIV-1 group M and non-M with the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 v2.0 and Abbott Real-Time HIV-1 PCR assays.
    Sire JM; Vray M; Merzouk M; Plantier JC; Pavie J; Maylin S; Timsit J; Lascoux-Combe C; Molina JM; Simon F; Delaugerre C
    J Acquir Immune Defic Syndr; 2011 Mar; 56(3):239-43. PubMed ID: 21164353
    [TBL] [Abstract][Full Text] [Related]  

  • 14. High correlation between the Roche COBAS® AmpliPrep/COBAS® TaqMan® HIV-1, v2.0 and the Abbott m2000 RealTime HIV-1 assays for quantification of viral load in HIV-1 B and non-B subtypes.
    Karasi JC; Dziezuk F; Quennery L; Förster S; Reischl U; Colucci G; Schoener D; Seguin-Devaux C; Schmit JC
    J Clin Virol; 2011 Nov; 52(3):181-6. PubMed ID: 21813320
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of the rate and size of HIV-1 viral load blips with Roche COBAS TaqMan HIV-1 versions 1.0 and 2.0 and implications for patient management.
    Garrett NJ; Apea V; Nori A; Ushiro-Lumb I; Oliver AR; Baily G; Clark DA
    J Clin Virol; 2012 Apr; 53(4):354-5. PubMed ID: 22261125
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of effect of specimen-handling parameters for plasma preparation tubes on viral load measurements obtained by using the Abbott RealTime HIV-1 load assay.
    Fernandes H; Morosyuk S; Abravaya K; Ramanathan M; Rainen L
    J Clin Microbiol; 2010 Jul; 48(7):2464-8. PubMed ID: 20484602
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Performance of NucliSens HIV-1 EasyQ Version 2.0 compared with six commercially available quantitative nucleic acid assays for detection of HIV-1 in China.
    Xu S; Song A; Nie J; Li X; Wang Y
    Mol Diagn Ther; 2010 Oct; 14(5):305-16. PubMed ID: 21053996
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of the RealTime HIV-1, COBAS TaqMan 48 v1.0, Easy Q v1.2, and Versant v3.0 assays for determination of HIV-1 viral loads in a cohort of Canadian patients with diverse HIV subtype infections.
    Church D; Gregson D; Lloyd T; Klein M; Beckthold B; Laupland K; Gill MJ
    J Clin Microbiol; 2011 Jan; 49(1):118-24. PubMed ID: 21084515
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of the bioMérieux NucliSENS EasyQ HIV-1 v2.0-HIV-1 RNA quantification assay versus Abbott RealTime HIV-1 and Roche Cobas TaqMan HIV-1 v2.0 on current epidemic HIV-1 variants.
    Mourez T; Delaugerre C; Vray M; Lemée V; Simon F; Plantier JC
    J Clin Virol; 2015 Oct; 71():76-81. PubMed ID: 26318912
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparative evaluation of the performance of the Abbott RealTime HIV-1 assay for measurement of HIV-1 plasma viral load on genetically diverse samples from Greece.
    Katsoulidou A; Rokka C; Issaris C; Haida C; Tzannis K; Sypsa V; Detsika M; Paraskevis D; Hatzakis A
    Virol J; 2011 Jan; 8():10. PubMed ID: 21219667
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.